Key Facts: NRPP RMP Exam
165
Questions (150 scored + 15 unscored) in 3 hours
NRPP RMP exam page
$175
Non-refundable exam fee; schedule within 30 days of registration
NRPP
2
Standards available inside the exam: MAH-2023 and MS-QA-2023
NRPP open-standards exam policy
16 hours
NRPP-approved initial training required for certification
NRPP certification requirements
30 days
Mandatory wait between attempts, maximum 4 attempts per 12 months
NRPP retake policy
48-72 hrs
Time to receive official emailed results
NRPP / Certiverse
2 years
Certification cycle, renewed with 12 CE hours
NRPP renewal policy
The NRPP RMP exam is taken by radon testers, home inspectors, and environmental consultants who want to provide professional radon measurement services and supervise field technicians. The 3-hour, 165-question Certiverse exam (150 scored) covers two blueprint sections. The field technician section (85 questions) tests client communication, site evaluation, MAH-2023 device placement (3 ft from doors and windows, 1 ft from exterior walls, 20 in above the floor), closed-building conditions starting 12 hours before tests under 4 days, 48-hour minimum durations, record keeping, and ethics. The professional section (65 questions) tests radon science and health risk, device selection and data validation, report preparation and follow-up recommendations, MS-QA-2023 QA plans with duplicates (10%), blanks (5%), spikes (3%), and annual CRM calibration, plus technician oversight and worker exposure. Both 2023 standards are viewable inside the exam, but time pressure rewards memorized fluency. Passing uses an unpublished criterion-referenced cut score; results arrive within 48-72 hours. Retakes require a 30-day wait, with at most four attempts per 12 months.
Sample NRPP RMP Practice Questions
Try these sample questions to test your NRPP RMP exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.
1Radon-222, the isotope of primary concern in indoor air, is produced directly by the radioactive decay of which radionuclide?
2What is the approximate half-life of radon-222?
3Which mechanism delivers most of the radiation dose to lung tissue from indoor radon exposure?
4According to the EPA, approximately how many lung cancer deaths in the United States are attributed to radon exposure each year?
5When communicating radon risk to a client, which statement correctly describes radon's ranking as a cause of lung cancer?
6A measurement result of 4.0 pCi/L is equivalent to approximately what concentration in SI units?
7The World Health Organization recommends that countries adopt what national reference level for indoor radon where feasible?
8Which statement correctly defines one Working Level (WL)?
9A technician accumulates 85 hours of work time in an environment averaging 0.5 WL. What is the technician's exposure in Working Level Months (WLM)?
10Simultaneous measurements in a home show 5.0 pCi/L of radon gas and 0.02 WL of decay products. What is the equilibrium ratio?
About the NRPP RMP Exam
The NRPP Radon Measurement Professional (RMP) credential certifies individuals to conduct, interpret, and report radon measurements and to manage measurement QA/QC programs. The exam contains 165 multiple-choice questions (150 scored plus 15 unscored trial items) delivered in 3 hours via live online proctoring on the Certiverse platform. It is an open-standards exam: ANSI/AARST MAH-2023 and MS-QA-2023 are accessible within the exam interface. Candidates must first complete a 16-hour NRPP-approved initial course, and certification renews on a 2-year cycle with 12 CE hours.
Questions
165 scored questions
Time Limit
3 hours
Passing Score
Criterion-referenced (not published)
Exam Fee
$175 (National Radon Proficiency Program (NRPP))
NRPP RMP Exam Content Outline
Client Communication & Radon Risk
Communicating health risk (radon as the second leading cause of lung cancer, 21,000 annual U.S. deaths, smoking synergy), the EPA 4.0 pCi/L action level and 2-4 pCi/L consider range, explaining required protocols, and recommending short-term, long-term, and follow-up testing approaches
Test Site Evaluation
Choosing the lowest level suitable for occupancy, planning multi-foundation and multi-location tests, recognizing result-impacting factors (severe weather, whole-house fans, evaporative coolers, fireplaces), and inspecting existing mitigation systems including U-tube manometer checks
Performing Tests & Device Placement
MAH-2023 placement rules (3 ft from exterior doors and windows, 1 ft from exterior walls, at least 20 in above the floor, 4 in object clearance), closed-building conditions 12 hours before tests under 4 days, 48-hour minimum duration, duplicate co-location, and tamper deterrence
Measurement Data Validation
Selecting charcoal, electret, alpha track, and continuous monitor devices; assessing CRM hourly data for diurnal patterns versus interference; RPD, equilibrium ratio, and pCi/L-Bq/m3 conversions; decay corrections; and interpreting recorded site data
Reporting, Records & Recommendations
MAH-2023 professional report contents (locations, device IDs, start/stop times, results, conditions, deviations), site-factor disclosure, chain of custody, non-interference agreements, post-mitigation verification timing (24 hours to 30 days), and retest-every-2-years guidance
QA/QC Program & Professional Oversight
MS-QA-2023 QA plan elements (SOPs, training, calibration, control charts, corrective action), duplicate (10%), blank (5%), and spike (3%) rates, annual CRM calibration, ethics and conflict-of-interest disclosure, scope of practice, worker exposure in working level months, and RMFT supervision
How to Pass the NRPP RMP Exam
What You Need to Know
- Passing score: Criterion-referenced (not published)
- Exam length: 165 questions
- Time limit: 3 hours
- Exam fee: $175
Keys to Passing
- Complete 500+ practice questions
- Score 80%+ consistently before scheduling
- Focus on highest-weighted sections
- Use our AI tutor for tough concepts
NRPP RMP Study Tips from Top Performers
Frequently Asked Questions
How many questions are on the NRPP RMP exam?
165 multiple-choice questions: 150 scored plus 15 unscored trial questions. The blueprint splits the scored items into a Measurement Field Technician section (85 questions) and a Measurement Professional section (65 questions). You have 3 hours.
Is the NRPP RMP exam open book?
It is an open-standards exam. ANSI/AARST MAH-2023 and MS-QA-2023 are accessible within the Certiverse exam interface, but no personal notes or other materials are allowed. With 165 questions in 180 minutes, you cannot rely on looking everything up.
What score do I need to pass the RMP exam?
NRPP uses a criterion-referenced passing point set through psychometric standard-setting rather than a published percentage. A preliminary result appears at completion and official results are emailed within 48-72 hours.
What does the NRPP RMP exam cost?
The exam fee is $175 and is non-refundable; you must schedule and complete the exam within 30 days of registration. After passing, initial certification costs an additional $275-$325, and the credential renews every 2 years with 12 CE hours.
What happens if I fail the RMP exam?
You must wait at least 30 days and repurchase the exam before retaking it. NRPP allows a maximum of four attempts in any 12-month period.
What are the prerequisites for the RMP exam?
You must complete a 16-hour NRPP-approved initial radon measurement course before certification. The exam is delivered online with live remote proctoring, requiring a government-issued photo ID, a webcam room scan, and a cleared workspace.
Which standards should I study for the RMP exam?
ANSI/AARST MAH-2023 (Protocol for Conducting Measurements of Radon and Radon Decay Products in Homes) and ANSI/AARST MS-QA-2023 (Quality Assurance). Placement distances, closed-building rules, reporting requirements, and QA plan elements come straight from these two documents.