General
Not publishedof exam
Communications
Not publishedof exam
Fireground Operations
Not publishedof exam
Rescue Operations
Not publishedof exam
Fire and Life Safety Initiatives, Preparedness, and Maintenance
Not publishedof exam
Quick Facts
- Current standard
- NFPA 1010 (2024), Chapter 7
- Legacy standard
- NFPA 1001 (2019), Chapter 5
- Prerequisite
- Firefighter I for certification
- Accreditation
- Pro Board or IFSAC
- Assessments
- Knowledge and practical skills
- Question count and time
- Set by certifying agency
- Passing rules
- Set by certifying agency
- National domain weights
- Not published
Command Handoff
Situation, plan, people, hazards, announce
Division vs Group
Division
- Geographic responsibility
- Second-floor crews
Group
- Functional responsibility
- Ventilation crews
Match area or function
Command Decisions
- First on scene and authorized→Establish command per policy(Transmit initial size-up)
- Incoming commander takes over→Brief and announce transfer(Pass accountability status)
- Too many direct reports→Delegate or redistribute assignments(Keep span manageable)
- Personnel assigned by area→Use a division(Geographic responsibility)
- Personnel assigned by function→Use a group(Functional responsibility)
Standards and Accreditation
- NFPA 1010 Chapter 6
- Firefighter I qualification
- NFPA 1010 Chapter 7
- Firefighter II qualification
- NFPA 1001 Chapter 5
- Legacy Firefighter II qualification
- JPR
- Job performance requirement
- NFPA
- Publishes professional qualification standards
- Pro Board and IFSAC
- Accredit certifying agencies
- Certifying agency
- Tests and certifies candidates
- Reciprocity
- Receiving agency sets conditions
- Exam edition
- Check agency's adopted standard
Legacy JPR Crosswalk
- General
- 5.1 became 7.1
- Communications
- 5.2 became 7.2
- Fireground operations
- 5.3 became 7.3
- Rescue operations
- 5.4 became 7.4
- Life safety and maintenance
- 5.5 became 7.5
Agency Exam Examples
- Missouri written exam
- 50 questions in 60 minutes
- Pennsylvania written exam
- 100 questions in 120 minutes
- Missouri passing score
- 70% on written exam
- Pennsylvania passing score
- 70% on written exam
- Missouri and Pennsylvania
- Practical skills also required
Command and Accountability
- 7.1.2
- Skills include command and transfer
- ICS
- Incident Command System
- Initial size-up
- Conditions, hazards, actions, resource needs
- Command transfer
- Brief incoming commander
- Transfer announcement
- Notify all incident personnel
- Handoff contents
- Situation, plan, resources, hazards
- Unity of command
- One designated supervisor per person
- Span of control
- Direct reports per supervisor
- Optimal FEMA span
- 1 supervisor to 5 subordinatesGuideline
- Accountability
- Track personnel and assignments
Help Request
Unit, location, problem, help needed
Radio Request vs Incident Report
Radio request
- Immediate operational need
- Send through command structure
Incident report
- Formal record of incident
- Include actions and outcomes
Match message to its purpose
Communication Decisions
- Crew needs more personnel→Request help through command(State location and assignment)
- New hazard affects assignment→Send a condition update(State operational impact)
- Firefighter needs immediate rescue→Use department Mayday procedure(Follow local radio protocol)
- Document a completed incident→Complete the incident report(Include actions and outcome)
- Witness gives unverified account→Attribute the statement(Identify source in narrative)
Incident Reports
- 7.2.1
- Complete basic incident report
- Core facts
- Who, what, when, where
- Timeline
- Incident times in chronological order
- Resources
- Units and personnel involved
- Incident narrative
- Conditions, actions, outcomes
- Witness statement
- Attribute to the speaker
- Cause undetermined
- Record uncertainty per agency policy
- Report destination
- Department reporting system
Radio and Team Assistance
- 7.2.2
- Communicate need for team assistance
- Plain language
- Common terms across agencies
- Call identification
- Identify recipient and sending unit
- Crew location
- Specify floor, side, or area
- Request details
- Need, reason, location, urgency
- Changing conditions
- Report impact on assigned task
- Acknowledgment
- Confirm critical message was received
- Emergency traffic
- Use department priority procedures
Building Finished Foam
Concentrate plus water, then add air
Hydrocarbon vs Polar Solvent
Hydrocarbon
- Gasoline or diesel
- Foam approved for hydrocarbon fuels
Polar solvent
- Ethanol is water-miscible
- Compatible alcohol-resistant foam
Match foam approval to fuel
Fireground Decisions
- Ventilation requested during attack→Coordinate timing with command(Link to suppression readiness)
- Polar solvent identified→Select compatible alcohol-resistant foam(Verify product approval)
- Gasoline spill needs vapor suppression→Select compatible Class B foam(Verify product approval)
- Hotspot suspected behind wall→Check for surface heat patterns(Confirm by approved methods)
- Heated cylinder is venting→Report continuing BLEVE risk(Follow command and department procedures)
- Possible origin evidence located→Protect it in place(Notify command or investigator)
Interior Attack Coordination
- 7.3.2
- Coordinate interior attack line
- Crew briefing
- Assignment, approach, hazards, egress
- Crew integrity
- Maintain contact and accountability
- Ongoing size-up
- Reassess conditions and fire spread
- Flow path
- Volume between inlet and outlet
- Gas movement
- Higher pressure toward lower pressure
- Ventilation timing
- Coordinate with suppression and search
- Progress report
- Conditions, actions, needs
- Changing fire conditions
- Update incident command promptly
Evidence Reminder
Protect, document, notify
Foam Solution vs Finished Foam
Foam solution
- Concentrate diluted with water
- Product of proportioning
Finished foam
- Air incorporated into solution
- Expanded bubbles form blanket
Air distinguishes the finished foam
Foam Selection and Terms
- 7.3.1
- Team extinguishment of ignitable liquid fire
- Class B foam
- Ignitable liquid fire application
- Hydrocarbon fuel
- Gasoline is a common example
- Polar solvent
- Ethanol is water-miscible
- Alcohol-resistant foam
- For approved water-miscible fuels
- Foam concentrate
- Undiluted foam product
- Foam solution
- Concentrate mixed with water
- Finished foam
- Aerated foam solution
- Foam blanket
- Suppresses flammable vapor release
- Proportioner
- Meters concentrate into water
- Foam selection
- Verify fuel, tools, and proportioning
- Fluorine-free foam
- Verify product's fuel compatibility
- Foam expansion ratio
- Finished foam volume ÷ solution volume
Fire Origin vs Fire Cause
Origin
- Where the fire began
- Document scene conditions and location
Cause
- How ignition occurred
- Report observations to investigator
Preserve evidence for both
Foam Application
- Roll-on
- Foam spreads from pool edge
- Bank-down
- Foam flows down adjacent surface
- Rain-down
- Foam settles from above
- Intact foam blanket
- Limits vapor and reignition risk
Thermal Imagers
- 7.3.3
- Operate a thermal imager
- Thermal imager
- Displays apparent surface heat patterns
- Victim search
- Use heat contrast as clue
- Overhaul
- Locate and verify suspected hotspots
- Container liquid level
- May show surface temperature boundary
- Walls
- Surface clues to hidden heat
- Glass and polished metal
- Can reflect infrared radiation
- Thermal image
- Interpret with other scene cues
- Legacy NFPA 1001 Chapter 5
- Thermal imaging lacked standalone JPR
Gas Cylinder Hazards
- 7.3.4
- Team control of flammable-gas cylinder
- BLEVE
- Boiling liquid expanding vapor explosion
- Flame impingement
- Can weaken cylinder shell
- Relief valve
- Venting leaves rupture risk
- Rupture hazards
- Blast, fragments, possible fireball
- Leak still flowing
- Unburned gas can accumulate
- Exposure control
- Protect threatened people and property
- Legacy gas-cylinder JPR
- NFPA 1001 section 5.3.3
Evidence Preservation
- 7.3.5
- Protect cause and origin evidence
- Area of origin
- Location where ignition began
- Fire cause
- What brought about ignition
- Scene perimeter
- Limits unauthorized access
- Potential evidence
- Protect in place when possible
- Unavoidable disturbance
- Record what moved and why
- Evidence observations
- Document location and original condition
- Investigator handoff
- Share observations and scene changes
- Legacy evidence JPR
- NFPA 1001 section 5.3.4
Chocks vs Cribbing
Wheel chocks
- Limit rolling at wheels
- Address horizontal movement
Cribbing
- Supports vehicle load
- Limits shifting and rocking
Combine as stabilization needs dictate
Rescue Decisions
- Vehicle can roll or shift→Establish stabilization before extrication(Recheck as loads change)
- Hybrid or electric model identified→Consult model-specific response guide(Locate high-voltage components)
- Patient exposed to tool debris→Provide shielding during extrication(Coordinate with patient care team)
- Technical rescue team requests support→Stage assigned tools and equipment(Work within assigned role)
Vehicle Extrication
- 7.4.1
- Extricate trapped vehicle occupant
- Scene assessment
- Traffic, vehicle position, patient access
- Wheel chocks
- Limit wheel movement
- Cribbing
- Supports vehicle and limits rocking
- Laminated glass
- Interlayer holds fragments together
- Tempered glass
- Breaks into small fragments
- Spreader
- Separates or displaces material
- Cutter
- Severs vehicle components
- Ram
- Pushes components apart
- Airbags and pretensioners
- Potential stored energy hazards
- Electric vehicle
- High-voltage components require identification
- Patient protection
- Shield from tools and debris
Technical Rescue Support
- 7.4.2
- Assist specialized rescue teams
- Perimeter control
- Keep unauthorized people clear
- Equipment staging
- Prepare tools requested by specialists
- Rescue assignment
- Support within training and authorization
- Scene briefing
- Pass along location and hazards
- Specialist entry
- Requires appropriate rescue qualifications
Hose Test Record
Hose, date, pressure, result
Fire Safety vs Preincident Survey
Fire safety survey
- Find hazards in occupied structures
- Recommend occupant safety improvements
Preincident survey
- Collect responder planning information
- Record access and fire protection
Match survey to intended use
Preparedness Decisions
- Occupant fire hazards need review→Perform fire safety survey(Discuss corrective actions)
- Crews need building response data→Prepare preincident survey(Record access and systems)
- Station visitors need escape guidance→Give fire safety presentation(Use audience-appropriate examples)
- Damaged light cord found→Remove equipment from service(Report and record defect)
- Annual hose test fails→Remove affected hose from service(Document hose ID and outcome)
Fire Safety and Preincident Surveys
- 7.5.1
- Survey occupied structure for hazards
- 7.5.3
- Prepare preincident survey
- Occupant safety survey
- Identify hazards and corrective actions
- Exit access
- Check for blocked escape routes
- Detection
- Check smoke alarm coverage
- Preincident survey
- Gather site data for responders
- Site plan
- Access, hydrants, exposures, hazards
- Building plan
- Layout, exits, protection systems
- Utility locations
- Record shutoffs for response planning
- Fire protection systems
- Note sprinkler and standpipe locations
- Fire department connection
- Identify location on preincident plan
Hose Inspection vs Service Test
Inspection
- Visual damage and wear check
- Includes jacket and couplings
Service test
- Verifies performance under test pressure
- Records pass or fail
Inspect hose before applying pressure
Public Fire Safety Education
- 7.5.2
- Present fire safety information
- Audience
- Station visitors or small groups
- Message delivery
- Match language to the audience
- Home escape plan
- Two ways out per room
- Family meeting point
- Pick a place outside
- Smoke alarm upkeep
- Test smoke alarms monthly
- Understanding check
- Ask audience to explain actions
Power Tools and Lighting
- 7.5.4
- Maintain generators, tools, and lighting
- Manufacturer instructions
- Guide maintenance and function checks
- Power tools
- Inspect guards and moving parts
- Portable lights
- Inspect cords, plugs, lamp condition
- Generator exhaust
- Carbon monoxide hazard
- Portable generator placement
- Outdoors away from building openings
- Defective equipment
- Remove from service and report
- Maintenance record
- Log checks, defects, corrective work
Annual Hose Service Test
- 7.5.5
- Annual fire hose service test
- Pretest inspection
- Check jacket and couplings
- Applicable test pressure
- Check hose marking and procedure
- Trapped air
- Purge before test pressurization
- Coupling witness mark
- Reveals slippage during test
- Hose test failure
- Tag and remove affected hose
- Test record
- Hose ID, date, pressure, result
Common Traps
Standards and testing
NFPA qualification standard ≠ Agency test blueprint
Transfer of command
Officer arrives ≠ Command formally transfers
Span of control
FEMA's optimal span guideline ≠ Fixed staffing rule
Thermal imaging
Surface heat pattern ≠ Confirmed hidden fire
Cylinder venting
Relief valve operates ≠ Rupture risk eliminated
Evidence
Possible ignition clue ≠ Confirmed fire cause
Vehicle energy
Ignition turned off ≠ Stored energy hazards eliminated
Hose readiness
Visual inspection passed ≠ Pressure test passed
Last Minute
- 1.Verify your agency's exam edition
- 2.Map Chapter 7 job requirements
- 3.Brief and announce command transfer
- 4.State location when requesting assistance
- 5.Record observed facts and outcomes
- 6.Coordinate ventilation with fire attack
- 7.Match Class B foam to fuel
- 8.Treat thermal images as clues
- 9.Remember venting cylinders can rupture
- 10.Protect possible evidence in place
- 11.Stabilize before vehicle extrication
- 12.Distinguish safety and preincident surveys
- 13.Remove failed hose from service
Explore More Firefighter Certifications
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
More From This Family
Videos and articles for deeper review.