Pipeline Inspection and Management
Not publishedof exam
Front-End Construction
Not publishedof exam
Installation Construction
Not publishedof exam
Back-End Construction
Not publishedof exam
Post-Construction
Not publishedof exam
Quick Facts
- Exam
- API 1169
- Scope
- New onshore pipeline construction
- Time
- 3 hours
- Format
- Multiple choice
- Questions
- 115 total, 100 scored
- Pretest
- 15 unscored questions
- Passing score
- 400 on 200–500 scale
- Delivery
- In-person computer exam
- Personal references
- Prohibited
- Onscreen references
- Selected government excerpts
- Effectivity window
- Dec 2026 – Aug 2027
OSHA Part Numbers
1910 industry, 1926 construction
Onscreen vs Study References
Onscreen excerpts
- Government documents
- Listed on effectivity page two
Study publications
- API standards and other publications
- Unavailable inside the test viewer
Check which references are provided
Exam Reference Picker
- Need tested editions→Use the effectivity sheet(Match your exam window)
- Need tested topic areas→Use the Body of Knowledge(Five main categories)
- Question specifies OSHA→Use the OSHA excerpt(Match the cited topic)
- Choosing a welding study reference→API 1104 or CSA Z662:23(Exam tests overlapping content)
- U.S. gas pipeline construction→Use 49 CFR 192(Construction in Subpart G)
- U.S. hazardous liquid construction→Use 49 CFR 195(Construction in Subpart D)
- Need U.S. wetland procedures→Find the FERC PDF(May 2013 exam reference)
- Need to navigate test PDFs→Practice with API tutorial(Ctrl+F unavailable)
Study Publications
- API RP 1169
- Construction inspection2nd edition
- API RP 1110
- Steel pipeline pressure testing7th edition, appendices excluded
- API Spec Q1
- Quality management systems10th edition, §§ 3–5
- API Spec Q1 updates
- Addenda 1–2 and Errata 1–3
- CGA Best Practices
- Underground damage preventionCurrent edition
- INGAA CS-S-9
- Pressure test safetyDecember 2018
- API Std 1104
- Welding, inspection and acceptance22nd edition, §§ 3–11
- API Std 1104 update
- Errata 1September 2023
- CSA Z662:23
- Canadian pipeline systems standardChs. 1, 2, 4, 6–10
Shoring vs Shielding
Shoring
- Supports excavation sides
- Designed to prevent cave-ins
Shielding
- Withstands cave-in forces
- Protects workers inside
Support walls vs protect occupants
Exam Screen References
- 49 CFR 192
- U.S. gas pipeline safety
- 49 CFR 195
- U.S. hazardous liquid pipeline safety
- 29 CFR 1910
- OSHA general industry standards
- 29 CFR 1926
- OSHA construction standards
- FERC May 2013 Procedures
- Wetland and waterbody mitigation
- 50 CFR 21
- U.S. migratory bird permits
- Canada OHS Regulations
- Federal occupational safetySOR 86-304
- Migratory Birds Convention Act
- Canadian migratory bird protection1994
- PDF viewer
- Ctrl+F unavailable
Quality Records
- Inspector role
- Observe, verify, document, report
- Controlled drawing
- Verify current approved revision
- Daily inspection report
- Record observations and test results
- Material traceability
- Link markings to material records
- Nonconformance report
- Document unmet requirement and disposition
- Calibration record
- Verify instrument calibration status
- Qualification records
- Verify credentials for assigned work
Site Safety
- OSHA competent person
- Identifies hazards, authorized to act
- OSHA trench egress
- ≥4 ft deep, ≤25 ft laterally29 CFR 1926.651(c)(2)
- OSHA cave-in protection
- Protective system unless exception applies29 CFR 1926.652
- Stable rock exception
- Excavation entirely in stable rock
- Under 5 ft exception
- Competent person finds no cave-in risk
- Shoring
- Supports excavation walls
- Shielding
- Protects workers inside the shield
- After rainstorm
- Competent person reinspectsWhen employee exposure is anticipated
- Pressure test exclusion zone
- Control access during pressurization
Route and Work Limits
Stake the route, mark utilities
Survey Stakes vs Utility Marks
Survey stakes
- Mark proposed route
- Show construction limits
Utility marks
- Mark estimated existing location
- Verify exact location near excavation
Proposed alignment vs existing facilities
Before Ground Disturbance
- Clearing limits unclear→Check approved alignment sheets(Include temporary workspace)
- Parcel restrictions unclear→Check the line list(Verify landowner commitments)
- Existing utility nearby→Safely verify exact location(Before digging near it)
- Crossing conditions unclear→Check crossing permit or agreement(Confirm method and limits)
- Runoff control needed→Check SWPPP and selected BMPs(Verify controls in place)
Alignment and Access
- Right of way (ROW)
- Corridor for pipeline work
- Alignment sheet
- Route, stationing and special conditions
- Survey stakes
- Mark designed location and limits
- PI
- Point of intersection
- Line list
- Parcel-specific requirements and commitments
- Utility locate marks
- Indicate estimated facility location
- Crossing permit
- Work conditions at regulated crossings
- Topsoil segregation
- Save topsoil separately for restoration
Environmental Controls
- SWPPP
- Stormwater pollution prevention plan
- BMP
- Best management practice
- Silt fence
- Intercept sediment in runoff
- Topsoil stockpile
- Keep separate where required
- Wetland work limits
- Check approved workspace and conditions
- Spill response
- Follow containment and reporting plan
Weld Paperwork
Procedure, proof, person
WPS vs PQR
WPS
- Tells welders how to weld
- Specifies production variables
PQR
- Records qualification test variables
- Records qualification test results
Instructions vs qualification evidence
Installation Inspection Checks
- Pipe joint at wrong station→Check tally against alignment(Verify grade and wall thickness)
- Pipe identity cannot be traced→Flag and segregate the joint(Follow project disposition process)
- Production welding about to start→Check WPS and welder qualifications(Verify applicable ranges)
- Weld indication reported→Apply governing acceptance criteria(Document disposition by weld ID)
- Holiday found before lowering→Verify repair and retest(Follow coating procedure)
- Tie-in spool cut→Verify transferred material identifiers(Update tie-in tally)
Stringing and Bending
- Stringing
- Lay joints along route
- Pipe tally
- Track joint identifiers and placement
- Heat number
- Links pipe to steel heat
- Pipe number
- Identifies the individual joint
- Material check
- Match grade, wall, coating
- Ovality
- Departure from circular cross-section
- Bend acceptance
- Check wrinkles, ovality, coating damage
- Bend record
- Record angle and installed location
Weld NDE vs Holiday Testing
Weld NDE
- Examines weld soundness
- RT or UT are examples
Holiday testing
- Checks coating continuity
- Uses electrical detector
Weld quality vs coating continuity
Weld Inspection
- WPS
- Welding procedure specification
- PQR
- Procedure qualification record
- Welder qualification
- Documents personnel qualification range
- Fit-up
- Check root gap and alignment
- Preheat
- Check before welding begins
- Interpass temperature
- Check between weld passes
- NDE or NDT
- Nondestructive examination or testing
- RT
- Radiographic testing
- UT
- Ultrasonic testing
- Repair record
- Trace repair and follow-up examination
Crossings and Trenching
- Crossing agreement
- Owner conditions and method constraints
- Ditch profile
- Check depth, width and support
- Underground clearance
- Separation from adjacent structures
- Depth of cover
- Distance from pipe top to surface
- Cased crossing
- Carrier pipe within protective casing
- HDD
- Horizontal directional drilling
- HDD inspection
- Track drill path and fluids
Coating and Lowering
- Field joint coating
- Protects exposed girth weld area
- Surface preparation
- Check cleanliness and profile
- Dry film thickness
- Measure thickness of dry coating
- Holiday
- Discontinuity in protective coating
- Jeeping
- Electrical check for coating holidays
- Padding
- Protect pipe from coarse material
- Lowering-in
- Check lift plan and pipe support
- Tie-in
- Connects adjoining pipe sections
- Tie-in tally
- Record pipe ID and cut length
Pressure Test Records
Section, instrument, chart
Coating vs Cathodic Protection
External coating
- Physical corrosion barrier
- Check damage and holidays
Cathodic protection
- Uses protective current
- Verify anodes and test leads
Barrier and electrochemical protection
Back-End Verification
- CP leads installed→Verify and record connections(Match approved CP drawings)
- Actual route differs from drawing→Capture survey and redline(Record actual conditions)
- Hydrotest about to start→Check instruments and exclusion zone(Follow approved test plan)
- Pressure drops during hold→Flag and record the change(Evaluate under test procedure)
- Bore restriction suspected→Check gauging results(Review plate condition)
Burial and Restoration
- Selected backfill
- Protect pipe and coating
- Compaction
- Verify project density requirements
- Backfill crown
- Allowance for settlement where specified
- Buoyancy control
- Check weight placement and spacing
- Topsoil replacement
- Restore segregated surface soil
- Bank stabilization
- Protect restored waterbody banks
- Revegetation
- Restore cover per project requirements
- Landowner restoration
- Check fences and parcel commitments
Hydrotest vs Gauging
Hydrotest
- Pressurized water
- Checks strength and leakage
Gauging
- Pig with gauge plate
- Checks for internal restrictions
Pressure integrity vs bore clearance
Cathodic Protection and As-Builts
- Cathodic protection (CP)
- Electrochemical corrosion control
- Anode bed
- Supplies protective current
- Test lead
- Provides electrical measurement access
- CP installation record
- Track anodes, leads and connections
- Redline
- Mark field changes on drawings
- As-built survey
- Records actual installed location
- As-built weld map
- Links weld IDs and locations
Hydrotest and Pigging
- Hydrostatic test
- Pressure test using water
- Test limits
- Verify test section boundaries
- Pressure chart
- Records pressure over time
- Test instruments
- Verify calibration before testing
- Intake and discharge
- Check applicable permits and conditions
- Cleaning pig
- Removes internal debris
- Gauge plate
- Screens for bore restrictions
- Dewatering pig
- Displaces residual bulk water
- Drying
- Meet specified moisture criterion
Closeout Evidence
Close, reconcile, hand off
Punch List vs As-Built
Punch list
- Outstanding deficiencies
- Tracks closure or disposition
As-built
- Actual installed configuration
- Captures field deviations
Work remaining vs installed condition
Turnover Checks
- Parcel restoration item open→Check line list closeout(Verify completion evidence)
- Deficiency found on walkthrough→Log it on punch list(Track disposition)
- Weld record missing at turnover→Reconcile weld map and reports(Resolve record gap)
- Accepted segment ready for handoff→Transfer records to operations(Follow project acceptance process)
Closeout Records
- Line list closeout
- Verify parcel commitments were resolved
- Final walkthrough
- Identify remaining deficiencies
- Punch list
- Track unresolved work and disposition
- Final inspection reports
- Document completed verification
- Turnover package
- As-builts, tests, inspection records
- Operations handoff
- Transfer accepted segment and records
Common Traps
Scaled scoring
400 scaled ≠ Fixed raw percent correct
Welding alternatives
Either welding study reference ≠ Both welding study references required
Trench entry
4 ft egress trigger ≠ Cave-in protection rule
Traceability
Heat number ≠ Individual pipe number
Stormwater
SWPPP planning document ≠ BMP field control
Burial geometry
Depth of cover ≠ Total trench depth
Closeout
Passed pressure test ≠ Complete turnover package
Last Minute
- 1.Match effectivity to exam window
- 2.400 is a scaled score
- 3.Use OSHA for OSHA questions
- 4.Verify utility location before digging
- 5.Trace each joint to material records
- 6.Check procedure and welder qualifications
- 7.Verify coating repairs before burial
- 8.Map welds and cathodic protection
- 9.Record hydrotest pressure over time
- 10.Resolve and document punch items
Third-party resources · We may earn a commission from purchases.

API 1169 EXAM Study Guide: In-depth review with 700+ Questions, Mock exams, 3 Practice tests, Detailed explanations and test-taking strategies for the Pipeline Construction Inspector Examination
By Fischer, Roderick W.
$35.80 · Buy on Amazon
Explore More API Inspector Certifications
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
More From This Family
Videos and articles for deeper review.