8.4 Vascular Access (IV/IO), Vasopressor Titration & Cardiogenic/Obstructive Shock
Key Takeaways
Short, wide catheters generally enable higher flow. The tubing, connectors, catheter and access site together determine actual delivery.
AHA recommends attempting IV access first for adult arrest medications. Use IO when initial IV attempts fail or are impracticable, following device and service instructions.
Check IO site integrity and watch for infiltration. Contraindications, flush and any analgesia depend on the device, patient, and service protocol.
Titrate vasoactive support to the treatment goal and monitor perfusion and access. Qatar DHP lists advanced vasoactive medication administration in the Critical Care Paramedic schedule.
Pulmonary edema with severe hypotension favors a pump failure pathway. Tension pneumothorax, tamponade and high-risk pulmonary embolism require different cause-specific responses.
Vascular access and cause-specific shock support
Choose access according to clinical urgency, site availability, intended therapy, and scope. Work in parallel with airway care, hemorrhage control or resuscitation. Before administering a medication or fluid, confirm the authorized route and check that access is patent and can be observed.
Flow and access
Under ideal laminar conditions, Poiseuille’s law relates flow to the pressure gradient, internal radius, length, and viscosity.
If internal radius doubles with everything else unchanged, the theoretical flow increases by . A short, wide-bore catheter is often useful for rapid volume delivery. Actual flow also depends on the connectors, tubing, infusion device, and fluid. Compare the whole setup and use components authorized for the product. Flow experiment using IV catheters and blood components
For adult arrest medications, the 2025 AHA guideline recommends trying IV access first. IO is reasonable when IV attempts are unsuccessful or not feasible. In time-critical shock, use the service plan for IV versus IO access and avoid delaying transport or life-saving interventions for repeated attempts. DHP includes peripheral IV and IO access in its Paramedic and Critical Care Paramedic procedure schedules. Use the approved skill level, equipment, medication route and service procedure. AHA adult advanced life support · DHP Paramedic scopes
Check the IO device and site
Select a site and needle suitable for the device and patient. For example, the Arrow EZ-IO clinical materials list adult proximal humerus and proximal or distal tibia sites, and an additional pediatric distal femur option. For that system, do not use a target bone with a fracture or an IO attempt in the last 48 hours. Check for local infection, significant orthopedic procedures and whether landmarks are identifiable. Other device instructions may differ.
Secure the catheter, check its stability, and confirm function with the approved technique. Infusion pain may warrant protocol-directed analgesia in a responsive patient. Use the recommended flush for the device and patient size. Check repeatedly for swelling, resistance, displacement, or leakage. If infiltration is suspected, stop using that access and follow the service plan. Confirm that the specific drug or product can be given by that route. Teleflex EZ-IO clinical materials
Vasoactive support
A vasopressor can increase vascular tone and arterial pressure. An inotrope primarily supports contractility, and some medicines do both. A rise in pressure does not necessarily mean adequate perfusion. Reassess cognition, pulses, capillary refill, breathing and rhythm. Match the drug to the cause and service protocol. DHP includes vasoactive medication administration in the Critical Care Paramedic schedule. Specific products and regimens require service approval.
For adult septic shock, norepinephrine is the 2026 guideline’s first-line choice. In an authorized setting peripheral administration can start without waiting for central access. Use the approved concentration and reliable delivery device. Label and trace the line and monitor for infiltration. If drug escapes into tissue, stop that infusion and follow the service’s extravasation procedure. In cardiogenic shock, vasoactive choice depends on hypotension, ventricular function and rhythm. An inotrope can reduce pressure in some patients. Avoid a fixed dose or MAP target across shock mechanisms. 2026 adult sepsis guideline · ACC cardiogenic shock guidance
Check the delivery path when the pressure changes. If hypotension worsens during a vasoactive infusion, reassess the patient and trace the line from the labeled container to the insertion site. Check pump settings against the order and verify that the line remains usable. Swelling or leakage suggests infiltration, while an intact line with a working pump makes a changing shock state more likely. Repeat the examination for bleeding, worsening congestion or a reversible obstructive cause. Make adjustments within the approved protocol and report the concentration, rate and patient response at handoff.
Pump failure and mechanical obstruction
| Presentation | Field decision |
|---|---|
| Acute myocardial ischemia with hypotension and pulmonary edema | Support oxygenation, obtain and transmit a 12-lead ECG, and activate the appropriate cardiac pathway. Avoid large empiric fluid boluses. Consider approved vasoactive support and tailor ventilation to perfusion. |
| Chest injury with findings of tension pneumothorax and deteriorating ventilation or circulation | Decompress when indicated and authorized. Use the patient-appropriate device and site from the service protocol. Reassess for improvement and recurrence. |
| Precordial injury and suspected tamponade | Support airway and perfusion, alert the trauma team and expedite definitive care. The full classic triad may be absent. |
| Abrupt dyspnea and shock with thromboembolic risk | Suspect high-risk pulmonary embolism, support oxygenation and perfusion, avoid indiscriminate volume loading, and alert the receiving team for time-critical evaluation and possible advanced therapy. |
A selected patient with right ventricular infarction or pulmonary embolism may need carefully assessed preload support. Clear breath sounds alone do not establish that a fluid bolus is safe or will help. Report what was given and how the patient responded. ACC cardiogenic shock guidance · NAEMSP pneumothorax statement · 2026 acute pulmonary embolism guideline
A conscious adult with life-threatening hemorrhagic shock has a fractured right tibia. Initial peripheral access attempts have failed. The service authorizes the Arrow EZ-IO system. The left proximal humerus is intact, and its landmarks are identifiable. What is the most appropriate access plan?
Keep trying peripheral cannulation at a distant site until successful even if care is delayed
Use an approved intact IO site such as the left proximal humerus and follow device and service guidance for confirmation, flush and analgesia
Place IO access through the fractured right tibia for proximity to injury
Choose a long narrow catheter chiefly because its length increases flow
An adult with anterior STEMI has BP 76/48 mmHg, SpO2 89%, bilateral crackles, and signs of poor perfusion. Which approach best fits suspected cardiogenic shock with pulmonary congestion?
Give an empiric large fluid bolus to normalize BP
Give nitroglycerin immediately despite the severe hypotension
Use an inotrope alone at a fixed high dose regardless of response
Support oxygenation, use authorized hemodynamic support with reassessment, and expedite the STEMI reperfusion pathway
Four days after knee arthroplasty, an adult develops abrupt pleuritic dyspnea, marked hypoxemia and BP 78/50 mmHg. The chest examination is symmetric. Which diagnosis and action are most appropriate?
Cardiogenic pulmonary edema, give a large empiric crystalloid bolus
Definite left tension pneumothorax, decompress based on BP alone
Suspected high-risk pulmonary embolism, support oxygenation and perfusion, avoid indiscriminate volume loading and pre-alert the receiving team
Uncomplicated anxiety, observe without circulatory support or transport escalation
Sections you finish are checked off in the contents.