18.3 Patient Movement, ETT Securement/Reassessment & Clinical Incident Reporting
Key Takeaways
Before transfer, protect the airway, secure lines and assign roles. Recheck ventilation, tube depth, waveform capnography and line integrity after movement.
Loss of a previously sustained waveform requires immediate patient and equipment assessment. Restore effective ventilation if tracheal position cannot be promptly confirmed.
Use the manufacturer’s restraints, cot, loading system and latches. Check load limits, brakes and team coordination before moving.
Qatar DHP Circular 2024/07 directs providers to match care to the patient using a minimum of two acceptable identifiers.
After a safety event, care for the patient, hand over facts and use the service’s reporting pathway. Review the circumstances and contributing system factors.
Protect the airway during movement
A tracheal tube or ventilator circuit can shift during loading, lifting or transfer. Before moving, secure the tube with the approved method, record its confirmed depth at the teeth or gums and assign a team member to protect the airway and support the circuit. Maintain ventilation and continuous waveform capnography through transport and movement whenever possible. After the move, recheck the waveform, connections, chest rise, bilateral breath sounds and tube marking. A signal with exhaled carbon dioxide does not establish whether the tip remains above the carina.
If a sustained waveform suddenly disappears, immediately assess the patient, circulation and ventilation. Check the airway, circuit and sampling connection. DOPE is a prompt to consider displacement, obstruction, pneumothorax or equipment failure, while watching for loss of perfusion. If the waveform cannot be restored and tracheal ventilation cannot be confirmed promptly, follow the failed-airway procedure. PUMA recommends removal of an unconfirmed tube by default unless removal itself is dangerous. If so, actively exclude esophageal placement by a valid method as soon as possible while protecting oxygenation. NAEMSP airway physiology statement, NASEMSO model EMS guidelines, PUMA airway consensus
Move and secure the patient as a team
Plan the route and request enough trained staff. Explain the move to the patient, assign a lead and use a clear count. Protect the head, airway, IV tubing and drains. Before a lateral transfer, align the surfaces, secure the brakes where applicable and use the approved transfer aid. Use powered loading or other mechanical assistance when available and appropriate. Check the load limits of the cot and loading system together, especially for heavier patients or equipment. An undersized crew should stop to request help rather than improvise a risky lift.
Close and inspect the manufacturer's required patient restraints. Raise side rails as directed by the device instructions and clinical needs. A side rail is not a restraint. Verify that the cot and compatible floor mount lock before vehicle movement. Keep the patient attended and avoid relying on an assumed latch sound or a universal restraint layout. Verify restraint and line integrity again after unloading. NIOSH ambulance crash testing, Stryker Power-PRO XT operations manual, EEAST bariatric movement policy
Match care to the right patient in Qatar
DHP Circular 2024/07 directs healthcare providers to use at least two acceptable identifiers before and during the care episode. Examples include full name, date of birth and an assigned identification number. The local facility or service specifies which identifiers to use consistently. A bed, bay or ambulance unit number describes a location or response, so it cannot stand in for a person-specific identifier. Use the designated emergency identification process for a patient whose identity is unknown. Hand over the identifiers in use along with findings, treatment and trends. Explicitly transfer responsibility for the airway, tube depth and waveform, active infusions and lines. DHP Circular 2024/07
Act, document and report after a safety event
| Situation | Example | Immediate field response |
|---|---|---|
| Near miss | Wrong epinephrine strength caught before injection | Resolve the discrepancy, protect the patient and report the intercepted hazard through the service’s process. |
| Adverse event | Infusion extravasation causes tissue injury | Stop the infusion, treat the patient, communicate the facts and follow the service’s reporting and disclosure pathway. |
| Possible sentinel medical event | Unanticipated severe patient harm after a transfer | Stabilize, notify the designated team promptly and document the facts for organizational review. |
Qatar DHP Circular 03/2019 requires healthcare facilities to maintain a process for recording and reporting sentinel medical events and investigating causes through their designated committee. The clinician should use the organizational reporting channel. Document the clinical facts, timing, findings, treatment and notifications. Report hazards even when the patient has recovered or an unsafe action was intercepted, according to the service’s procedures. DHP Circular 03/2019, AHRQ event investigation guide
A Just Culture review looks at system factors and behavior. An inadvertent slip may call for support and redesign, a shortcut taken because the risk was underestimated may call for coaching and workflow changes, and conscious disregard of a substantial unjustifiable risk may require accountability. Investigate the circumstances before assigning a category. VA Just Culture decision support
Immediately after transferring an intubated, hemodynamically stable trauma patient from the ambulance stretcher onto the emergency department bed, the continuous waveform capnography suddenly drops to zero and flatlines while a strong carotid pulse remains palpable. What should the paramedic do first?
Administer 1 mg of IV epinephrine 1:10,000 for suspected pulseless electrical activity
Immediately assess and support ventilation while checking tube position, chest movement, circuit and capnography connections
Silence the monitor alarm and observe for 3 minutes in case the sensor is warming up
Increase the ventilator respiratory rate to 30 breaths per minute to clear dead space
Before giving a medication in Qatar, which pair meets the DHP requirement for at least two acceptable patient identifiers when both are confirmed through the service’s process?
Ambulance call number and chief complaint
Hospital triage acuity category and stretcher bay number
Patient’s full name and date of birth
Patient's age estimate and physical clothing description
A cot operator skips a restraint that the manufacturer requires because he believes a short trip makes the risk negligible. An investigation confirms that he underestimated the risk. In a Just Culture framework, which response fits this finding?
Human error — console the paramedic only and take no further action
At-risk behavior — coach the paramedic to recognize the hidden risk and remove system pressures encouraging shortcuts
Reckless behavior — immediately revoke the paramedic's license for malicious intent
Sentinel event — report only if a patient actually falls off the stretcher
Sections you finish are checked off in the contents.