14.2 Gracey & Universal Curettes, Ultrasonic Scaling, and Long Junctional Epithelium Healing
Key Takeaways
Read the markings on the specific probe and record probing depth, attachment level and bleeding separately.
The standard universal curette has a 90° blade face-to-shank angle and two cutting edges. The Gracey has a 70° design angle and uses its lower cutting edge.
Use instrument-specific adaptation, water, and power. Choose a designated implant insert for the system and implant surface.
A smaller probing depth can reflect reduced swelling, recession or a gain in measured attachment. Reassessment uses both the site findings and the overall response.
Probe for attachment loss and instrument access
Use light, reproducible probing and chart probing depth (PD), clinical attachment level (CAL) and bleeding on probing (BOP). The 2025 European Workshop describes a contemporary manual probe with a 0.25 N force limiter. The WHO survey protocol uses a maximum force of 20 g (about 0.20 N). Histologic studies show that the probe can penetrate farther in inflamed tissues and may stop coronal to the junctional epithelial endpoint after treatment. Consider the exam purpose and technique when comparing readings. EFP diagnostic consensus · WHO survey methods · Original probe penetration study
| Probe | Identification and use |
|---|---|
| UNC-15 | Millimeter graduations through 15 mm for detailed site measurements. Verify any color-band pattern on the instrument. |
| Williams | Marks at 1, 2, 3, 5, 7, 8, 9 and 10 mm. The absent 4 and 6 mm marks help identify the scale. |
| Marquis | The Premier Marquis 12 has a 3 mm band sequence at 3, 6, 9 and 12 mm. Read the scale for the specific model. |
| WHO CPI | A 0.5 mm ball tip with a band from 3.5 to 5.5 mm and reference marks at 8.5 and 11.5 mm in the WHO survey specification. Use the relevant screening protocol. A positive screen may require detailed charting. |
| Nabers | A curved furcation probe for horizontal access to the furcations of multirooted teeth. One catalogue model is marked at 3, 6, 9 and 12 mm. |
Manufacturer instrument catalogue · Premier Marquis 12 catalogue · WHO CPI specification · Hamp et al., furcation and treatment study
Choose the appropriate hand instrument and working end
| Instrument | Blade geometry | Use |
|---|---|---|
| Sickle scaler | Triangular cross-section, pointed tip and back, two cutting edges. | Mainly for supragingival interproximal deposits. Select a rounded curette or a designated powered tip for deep subgingival access. |
| Universal curette | Rounded back and toe, face at 90° to the terminal shank, two usable cutting edges. | Adapt the appropriate edge to any tooth surface. Tilt the instrument as needed to engage the deposit with the blade face. |
| Gracey curette | Rounded back and toe, blade face at about 70° to the terminal shank, one lower working edge. | Match the working end to the surface. Initial alignment of the terminal shank with the tooth surface helps identify the lower working edge. Adapt the toe third around the contour and adjust the angle for the working stroke. |
| Standard Gracey patterns | Area |
|---|---|
| 1/2 and 3/4 | Anterior teeth. |
| 5/6 | Anterior teeth and premolars. |
| 7/8 and 9/10 | Posterior buccal and lingual surfaces. |
| 11/12 and 15/16 | Posterior mesial surfaces. |
| 13/14 and 17/18 | Posterior distal surfaces. |
A HuFriedy After Five pattern has a terminal shank 3 mm longer than standard and a thinner blade. The comparable Mini Five has a shortened blade as well. Select a shorter working end when it improves access and adaptation in a narrow pocket or around a line angle. A 15/16 is a posterior mesial pattern number. After Five denotes a separate shank and blade variant. HuFriedy clinical applications · 2025 manufacturer design table
Distinguish blade design from working angulation
Use a supported modified pen grasp and a stable finger rest. Adapt the toe third of a curette to the root and insert it with the blade face closed toward the root. Open the blade to engage the deposit before a controlled pull stroke. The blade face-to-tooth angle changes during these steps. The blade face-to-shank angle is a fixed design feature. The HuFriedy clinical guide illustrates an approximately 85° working angle for the calculus removal strokes shown. Correct a nearly closed working angle if the edge repeatedly slides over the deposit. Evaluate adaptation, access, sharpness and pressure as well. Use short controlled strokes and preserve root structure. Human root comparisons found that calculus removal and loss of tooth substance varied by instrument, and a clinical comparison did not establish a need to remove all exposed cementum for periodontal healing. HuFriedy applications and stroke guide · Original instrument comparison · Original clinical cementum study
Use a powered tip that matches the site and system
Magnetostrictive units drive the insert through a magnetic field, while piezoelectric units use electrically driven dimensional changes of piezoelectric elements. Laser vibrometry recorded elliptical motion in tested tips of both types. The motion varied with tip and loading. Follow the selected tip's instructions for the active surfaces, adaptation, power and water. The Cavitron Select SPS manual recommends a light touch and the lowest power suitable for the insert and clinical application. Follow the ultrasonic and cardiac device instructions and coordinate with the treating team if device compatibility is uncertain. In vivo work found telemetry interference in some tests without clinically significant disruption of implanted cardiac devices in the study. Three-dimensional scaler study · Cavitron Select SPS instructions · In vivo cardiac device study
For implant debridement, use a tip indicated for the system and implant surface. For example, the Cavitron SofTip implant insert uses its designated disposable tip. Laboratory studies show different changes in implant topography depending on the insert and surface. Use appropriate protective equipment and high-volume evacuation to control spatter and aerosols. A rinse may reduce microbial counts in dental spatter, but evidence that this prevents clinical infection is insufficient. Manufacturer implant insert instructions · Original implant-surface study · CDC dental infection-control guidance
Reassess the clinical response after tissue healing
EFP steps 1 and 2 pair patient plaque control and risk-factor management with subgingival instrumentation. Hand instruments, powered instruments or a combination can remove biofilm and calculus. A smaller PD may reflect less edema, recession, a gain in measured CAL or a change in probe penetration. Classic histology after root planing with soft-tissue curettage in an animal model showed a long junctional epithelial attachment. Clinical probing improvements alone cannot identify the attachment histologically or prove regeneration, which involves new cementum, functionally oriented periodontal ligament and alveolar bone. EFP Stage I–III guideline · Original healing histology study · EFP probe interpretation consensus
Reevaluate after adequate healing, at an interval informed by the initial severity, treatment and risk. The EFP guideline leaves timing to that clinical context. A randomized comparison of 3- and 6-month reassessment after steps 1 and 2 found similar primary outcomes in its sample. Record plaque, PD, BOP and attachment and compare with baseline. The EFP step-2 target is no residual pockets >4 mm with bleeding and no pockets ≥6 mm. Its Stage III step-3 access recommendation suggests repeat instrumentation for residual 4–5 mm pockets needing treatment and consideration of access surgery when deep pockets of ≥6 mm persist. Decide with the patient after assessing local anatomy, self-care, risks and prognosis. The separate case definition for stable treated periodontitis includes <10% BOP, PD ≤4 mm, no bleeding at 4 mm sites, and no progressive destruction. EFP guideline, Sections 4, 7 and R3.1 · Randomized timing trial
Which standard area-specific curette is designed to instrument the mesial surface of mandibular right first molar (FDI 46), and which edge is used?
Gracey 13/14 with two working edges
Columbia 13/14 with only a lower working edge
Gracey 11/12 with the lower working edge
Gracey 7/8 with a triangular pointed blade
After nonsurgical periodontal treatment, a molar site changes from 7 mm to 4 mm probing depth and no longer bleeds on probing. What can be concluded from these findings?
The site improved clinically, but probing cannot identify the attachment histologically
New acellular cementum with inserting fibers is proven
The isolated measurement establishes complete bone regeneration
The probe findings demonstrate ankylosis
A well-adapted curette has been inserted with its face closed toward the root. During the working stroke, the edge slides over a calculus deposit without engaging it. What adjustment is most appropriate?
Continue with the blade closed throughout
Change to a pointed sickle for deep subgingival access
Force the toe point into the cementum
Maintain toe-third adaptation and open the blade face for an effective working angle
Sections you finish are checked off in the contents.