11.2 Elastomeric Impressions and Gingival Tissue Management

Key Takeaways

  • Inspect the finish line in the impression and repeat the impression if detail is missing or the material has failed to set.

  • Some latex products inhibit PVS. Use compatible gloves and keep the prepared surface free of blood and residual medicament.

  • Polyether can reproduce detail in a slightly moist field. Assess undercuts and follow its specific disinfection, dry-storage and pouring instructions.

  • Use gentle tissue displacement and local hemostasis matched to the site. Account for every cord after the impression.

Last updated: November 2026

Choose the Material and Inspect the Impression

Identify the finish line, gingival health, undercuts and degree of moisture before selecting a material and tray. Provide a stable tray with a compatible adhesive and adequate space for the wash. Work within the selected material's mixing, working and intraoral setting times. Keep the tray still until the material sets. Check the entire margin for voids, tearing, pulls, unset material and evidence of tray separation. Repeat an inadequate impression before proceeding to the cast. Aquasil Ultra+ 2025 instructions · Impression margin thickness experiment

ElastomerMaterial properties and common handling issues
Addition silicone (PVS or VPS)Addition setting has no volatile condensation byproduct. Some formulations release hydrogen in side reactions. Some glove contaminants can inhibit setting. Hydrophilic formulations still need moisture control for fine detail.
PolyetherGood wettability and relatively high set stiffness. Check deep undercuts and delicate structures before choosing it. Humidity and excessive immersion can affect the material or resulting cast.
Condensation siliconeThe conventional setting reaction releases alcohol. Continued dimensional change depends on the formulation and storage of the impression.
PolysulfideIts conventional condensation setting chemistry produces water. An appropriately supported impression should be processed within the named product's time limits.

Hydrogen gas produced gypsum pitting in experiments with some addition silicones. That mechanism differs from an impression margin that is already sticky. Direct and indirect latex contamination have inhibited some PVS products in experiments. Results vary by glove, contact and formulation. Use the product's compatible gloves and barriers. Remove residual medicament and control fluids according to the instructions. Tested aluminum and ferric astringents did not invariably inhibit PVS in controlled work. Hydrogen release experiment · Latex contamination experiment · Astringent compatibility experiment

Polyether reproduced fine detail in a moist experimental setup more consistently than the two PVS materials tested. This still calls for control of active bleeding and fluid pooling. Stiffness differs by product and can complicate removal from deep undercuts. In humidity and storage experiments, polyether formulation and storage conditions both affected accuracy. For condensation silicones and polysulfides, loss of reaction byproducts and other processes can affect dimensions over time. Moisture experiment · Stiffness experiment · Polyether storage experiment · Silicone kinetics and dimensional experiment · Elastomer disinfection experiment

Clean, Disinfect and Communicate the Instructions

Remove oral debris, rinse and use a compatible disinfectant at its specified contact time. Rinse or dry as directed. Communicate disinfection status, product and applicable pouring limits to the laboratory. Check the local infection-control policy and the actual impression and disinfectant instructions. The timing anchor matters, including removal, impression taking, or disinfection. U.S. CDC dental laboratory guidance

Named instructionsExample of a processing or laboratory window
Aquasil Ultra+ PVS, 2025 IFUThe impression-processing table allows laboratory use immediately after the specified disinfection or after a delay of up to 14 days. Check the applicable IFU for the exact product and laboratory material.
3M Impregum Penta H DuoSoft polyether, 3100031642/01Uses a compatible impression disinfectant at its stated contact time, then a water rinse. Store the impression dry. Pour the indicated stone from 30 minutes to 14 days after taking the impression.
Zhermack Zetaplus System condensation siliconeDry after disinfection. The manufacturer advises casting within 72 hours after disinfection. It describes immersion or spray with a compatible product.
Kerr Permlastic polysulfide, 41222 Rev. 01-22The model-pouring section gives 30 minutes after removal or as soon as possible thereafter, with an 8-hour limit. Follow its separate cleaning and disinfection instructions.

Aquasil Ultra+ 2025 instructions · Impregum Penta H DuoSoft instructions · Zetaplus System instructions · Permlastic 41222 instructions

Expose the Margin and Control Bleeding

A finish line near or within the sulcus needs room for the wash to record it. Select a margin position that respects attachment. Evaluate and control inflammation before the definitive record when needed. A thin wash at the margin can tear or distort. Use gentle displacement with cord or a compatible paste as needed. Impression margin thickness experiment · World Workshop periodontal consensus

With a single cord, choose a size that produces adequate opening without tissue injury. Remove before syringing. With a double cord, an apical cord can help control fluid while a second cord provides lateral displacement. Remove the upper cord before syringing. Leave the apical cord for the impression only if the technique calls for it and the cord clears the finish line. Remove it from the sulcus after the impression, and confirm that every cord has been retrieved. Follow the selected product and technique for contact time, removal and rinsing. Ultradent double-cord technique, FDA submission · Ultradent aluminum chloride instructions

Aluminum chloride is one local astringent option for sulcular fluid or minor bleeding. Ferric sulfate is another hemostatic option. Follow the agent's application and removal instructions and verify hemostasis before syringing. Epinephrine can have systemic effects. A clinical trial found no handling advantage over aluminum sulfate cords. In a patient with cardiovascular risk, review the medical history before elective treatment and choose an appropriate local alternative when displacement is needed. Small studies in selected patients do not establish cardiovascular safety in higher-risk groups. Original gingival microcirculation trial · Original retraction-cord trial

Loading diagram...
Checking and Processing an Elastomeric Impression
Test Your Knowledge

A PVS margin is sticky and incomplete before the impression is poured. That site had been handled with an incompatible latex glove. What is the best response?

A

Accept the impression and pour it immediately

B

Keep the impression and extend the stone mixing time

C

Correct likely setting inhibition and repeat using compatible gloves and barriers

D

Diagnose hydrogen pitting on the gypsum die and keep the impression

Test Your Knowledge

A laboratory will pour an Impregum Penta H DuoSoft impression using IFU 3100031642/01. The impression has been disinfected as directed. It will be stored dry and poured 18 hours after impression taking. Does the stated interval allow this?

A

Yes. The stated stone interval is 30 minutes to 14 days after impression taking

B

No. This polyether must be poured before 30 minutes

C

No. Any storage after compatible disinfection is forbidden

D

Yes, but the impression must remain submerged in water until pouring

Test Your Knowledge

The upper cord has been removed in a double-cord procedure and the lower cord does not cover the finish line. After making the impression, what should the clinician do before completing the appointment?

A

Leave the lower cord to control fluid until crown delivery

B

Remove the lower cord and verify all cord and residual material are out of the sulcus

C

Pack a third cord into the sulcus while the laboratory works

D

Assume the impression removed both cords