4.8 Energy, Water & Resource Management
Key Takeaways
Solar PV, wind and hydro convert different primary inputs into electricity.
Pumped storage uses electricity to raise water, then releases it to generate electricity later.
Power in kilowatts multiplied by hours yields energy in kilowatt-hours when the power is constant.
Infiltration can recharge aquifers. Well levels reflect recharge, extraction and the season.
Rural tap service is assessed by access, quantity, quality and regularity.
Compare Energy Sources, Generators and Storage
A primary energy source provides energy from nature, such as sunlight, wind, flowing water or a fuel. Electricity is a means of carrying energy generated from such sources. Solar and wind inputs are replenished naturally. Coal is a finite fossil fuel. An exam question may ask how a source is converted, how steadily it produces, or how its output can be stored.
| Technology | Principal energy conversion or role |
|---|---|
| Solar photovoltaic | Cells convert sunlight directly into electricity. Output varies with available sunlight and system conditions. |
| Wind turbine | Moving air drives a rotor linked to a generator. Output varies with wind conditions. |
| Conventional hydropower | Water flowing through a turbine turns a generator. Flow and the difference in water levels affect output. |
| Thermal generation using coal | Fuel supplies heat. Steam can turn a turbine connected to a generator. |
| Battery or pumped storage | Takes in energy when it is available and supplies some of it later. Conversion and operating losses reduce the amount returned. |
In pumped storage, electricity drives pumps to move water from a lower to an upper reservoir. Releasing the stored water later can generate electricity through a turbine. A plant consumes energy during pumping and supplies energy during generation. The value comes from moving usable energy to a time of higher demand or lower supply. The Tehri pumped storage project in Uttarakhand is designed around two reservoirs and has a rated capacity of 1,000 MW. MNRE, energy statistics by source · U.S. Department of Energy, renewable generation and storage · U.S. Department of Energy, hydropower types · THDC, Tehri pumped storage
Power is the rate of energy transfer, measured in watts or kilowatts. Energy is the total transferred over an interval. At constant output, multiply power in kilowatts by time in hours to obtain kilowatt-hours. A load drawing 0.5 kW for four hours uses 2 kWh. A solar array rated at 3 kW that averages 1.5 kW over four hours supplies 6 kWh in that interval. Multiplying its rating by four would assume operation at full rated output throughout the interval. BIPM, SI · U.S. Department of Energy, solar technology basics
Track Surface Water and Groundwater
Rain falling in a catchment can run off toward streams, infiltrate the soil, evaporate or be taken up by plants. Infiltration is entry into the ground. Some infiltrated water continues down and recharges groundwater. An aquifer is a body of rock or sediment that can store and transmit groundwater. The water table is the upper surface of saturation in an unconfined aquifer. Its level can vary with recharge, pumping and season.
Suppose a village notices that the depth to water in its wells is smaller after the monsoon and greater before the next rainy season. A comparison at the same point in successive years is more informative about a longer trend than comparing one wet-season reading with one dry-season reading. Also check changes in rainfall and abstraction. Under suitable conditions, infiltration structures can support recharge. Reducing withdrawals and preventing contamination can also protect supplies. Many wells draw from the same aquifer, so planning solely by the number of new wells can miss the pressure on the shared resource. USGS, infiltration and the water cycle · USGS, aquifers and groundwater · CGWB, 2025 groundwater assessment
A watershed project can have several objectives at once. One pond might slow runoff and give water more time to infiltrate. Where soils or rocks transmit water poorly, a similar design may produce a different recharge result. For an evaluation, compare early and late season observations, note the rainfall, and track pumping alongside water levels. A rise in a nearby observation well after a storm provides a clue about local water conditions. To estimate the impact of the work itself, compare with previous years and with other wells under similar rainfall and withdrawal conditions. The catchment is the useful scale for considering upstream and downstream effects. USGS, infiltration and the water cycle
Distinguish Access, Quantity and Quality
The Jal Jeevan Mission aims for reliable rural household tap water of prescribed quality, with a service level of 55 litres per capita per day. The Union Cabinet approved JJM 2.0 in March 2026 and extended the mission to December 2028. Count connections to measure coverage. Check water testing, delivery and frequency to assess whether service is actually being provided. At the stated service level a village with 400 residents requires 22,000 litres a day for household use before allowing for losses.
Namami Gange has a different purpose from a household tap programme. Its river rejuvenation and pollution reduction work includes sewerage treatment and aquatic conservation. A village can record more tap connections while a nearby river still receives untreated wastewater. Choose the metric that matches the question, such as connection coverage, measured quality, treatment volume or source reliability. Ministry of Jal Shakti, JJM service level and extension · National Mission for Clean Ganga, Namami Gange
A school appliance draws a steady 1.2 kW for 2.5 hours. How much electrical energy does it consume?
0.48 kWh
1.2 kWh
3.0 kWh
3.7 kWh
Which action stores energy in a pumped storage plant during a period of surplus electricity?
Using electricity to move water to the upper reservoir
Releasing water to the lower reservoir through the generating turbine
Delivering electricity from the generator to the grid
Passing the output through a step-up transformer
At 55 litres per capita per day, what daily household service volume does a settlement of 320 residents require, before losses?
5,500 litres
17,600 litres
32,000 litres
55,000 litres
Sections you finish are checked off in the contents.