5.2 HPE MSA Software: Virtual Storage, MSA-DP+, Automated Tiering & SSD Read Cache

Key Takeaways

  • MSA virtual storage groups drives into disk groups, disk groups into up to two pools (each up to 4 PiB addressable), and pools into volumes of up to 128 TiB.

  • MSA-DP+ is an erasure-coding-based RAID level introduced with Gen6 that spreads data, parity and spare capacity across all drives, with default spare equal to the two largest drives.

  • Automated tiering moves 4 MB pages between the Performance (SSD), Standard (10K SAS) and Archive (7.2K midline SAS) tiers based on access patterns.

  • An Advanced Data Services license is needed to mix SSDs and HDDs in a system, except when the SSDs are used only as SSD read cache.

  • Volume tier affinity (QoS) biases a volume's pages toward the performance or archive tier without disabling automated tiering.

Last updated: October 2026

HPE MSA Software: Virtual Storage and Tiering

Quick Answer: MSA Gen7 uses virtual storage: drives form disk groups, disk groups join one of two pools (A or B, each owned by a controller), and volumes are thin-provisioned from a pool in 4 MB pages. The automated tiering engine moves hot pages to the Performance tier (SSD) and cold pages to the Standard (10K SAS) or Archive (7.2K midline) tier. Mixing SSDs and HDDs requires the Advanced Data Services (ADS) Suite, except when the SSDs serve only as SSD read cache.

The virtual storage hierarchy

ObjectDefinitionKey limits (Gen7 QuickSpecs)
Disk groupA set of drives of one type in one protection level (RAID 1, 5, 6, 10 or MSA-DP+)Can span enclosures
PoolOne or more disk groups; pool A is owned by controller A and pool B by controller BUp to 2 pools, each 4 PiB addressable
VolumeLogical unit presented to hosts, built from 4 MB pages spread across the poolUp to 128 TiB; up to 512 volumes per system
HostNamed set of initiators that volumes are mapped toUp to 512 hosts and 1,024 initiators

Because a volume's pages spread across every disk group in its pool, adding capacity also adds performance, and HPE states that data automatically reflows to balance utilization when a pool is expanded.

RAID levels and MSA-DP+

MSA Gen7 supports RAID 1, 5, 6 and 10 and MSA-DP+ for virtual disk groups. RAID 0 (NRAID) is allowed only for read cache.

MSA-DP+ is a RAID-based protection level introduced with the sixth-generation MSA. HPE describes it as using erasure coding to give better performance and availability and very fast rebuilds compared with traditional parity RAID:

  • Data, parity and spare capacity are distributed across every drive in the disk group. There are no idle dedicated spare drives.
  • The default target spare capacity equals the sum of the two largest drives, enough to restore full fault tolerance after losing any two drives.
  • After a failure, the rebuild writes to many drives in parallel, so it finishes much faster than rebuilding onto a single spare.
  • Drives in one MSA-DP+ group must be the same type. Capacities may differ, but HPE recommends that the largest drive be no more than twice the smallest.
  • A replacement drive inserted into the failed drive's slot joins the group automatically, and the group can be expanded incrementally.
ProtectionSurvivesSpare modelTypical use
RAID 10One drive per mirror pairDedicated sparesWrite-heavy SSD or 10K tiers
RAID 6Any two drivesDedicated sparesLarge HDD disk groups
MSA-DP+Any two drives, with fast distributed rebuildDistributed spare capacityLarge disk groups, especially high-capacity HDDs

The three tiers

TierMediaPurpose
PerformanceSSDHot data: database indexes, active VM blocks
StandardEnterprise 10K SAS HDDMainstream data
ArchiveMidline 7.2K SAS HDDCold data, file shares, backup copies

A tier is the set of disk groups of the same media class in a pool. A pool can contain one, two or all three tiers.

Automated tiering

MSA automated tiering (version 2.0 in Gen7) is sub-LUN: it moves individual 4 MB pages rather than whole volumes. The controllers track access to every page. Frequently accessed pages migrate up to the highest available tier, and pages that cool down migrate down. Movement is continuous and needs no scheduling.

The SMU I/O Workload view helps with sizing the SSD tier. It shows, over a 7-day timeline, what share of the I/O is served by what share of capacity. If 80% of I/O falls on a small slice of capacity, a modest SSD tier delivers most of the benefit.

Volume tier affinity

The QuickSpecs list Virtual Tier Affinity as the MSA quality-of-service feature. A volume's tier affinity can be:

  • No affinity (default): pages move purely on access patterns.
  • Performance: pages are biased toward the fastest tier, useful for a latency-sensitive database.
  • Archive: pages are biased toward the archive tier, useful for backup copies or rarely used data, so they do not compete for SSD space.

Affinity is a preference, not a pin. Tiering continues, and the tier capacity still limits what fits.

SSD read cache

SSD read cache is the low-cost alternative to an SSD performance tier:

  • One or two SSDs are added to a pool as a read cache disk group; RAID 0 is allowed because the cache holds only copies.
  • Frequently read data is copied to SSD. Writes go to the HDD disk groups, so losing a cache SSD loses no data.
  • The Gen7 array supports up to 8.34 TB (7.6 TiB) of read cache.
  • A pool uses either a performance tier or read cache, not both.

Licensing: what needs the Advanced Data Services Suite

The MSA Advanced Data Services (ADS) Suite is included with every MSA 2072 and optional on MSA 2070 models. It adds performance tiering, 512 snapshots and Volume Copy, and Remote Snap. HPE's rule is that an ADS license is required when HDDs and SSDs are mixed in the same system, except when SSDs are used only as read cache.

Pool APool BADS license needed?
HDDsHDDs or noneNo
SSDs (flash pool)SSDs (flash pool) or noneNo
HDDs with SSD read cacheHDDs, or HDDs with SSD read cache, or noneNo
SSDs (flash pool)HDDsYes
HDDs and SSDs (auto-tiering)AnyYes

Archive tiering between 10K and midline HDDs does not involve SSDs, so it does not trigger the license.

Thin provisioning and space reclamation

MSA virtual volumes are thin provisioned: pages are allocated only when data is written. HPE lists thin provisioning, space reclamation and thin rebuild as standard "thin technologies":

  • Space reclamation returns pages to the pool when hosts send SCSI UNMAP after deleting data.
  • Thin rebuild rebuilds only the allocated parts of a failed drive, shortening rebuilds on partly full disk groups.
  • Because pools can be overcommitted, monitor pool thresholds and alerts so the pool never runs out of space.

Host presentation

Volumes are mapped to hosts or host groups with a LUN number and access level. Present each volume through both controllers so ALUA multipathing can fail over. The MSA also supports the VMware VAAI primitives (hardware-assisted locking, copy offload and block zeroing) and LDAP authentication of administrators against Active Directory.

Common exam traps

  • Tiering versus read cache: tiering moves the only copy of data and needs ADS when SSDs and HDDs are mixed; read cache holds disposable copies and does not need ADS.
  • One acceleration method per pool: performance tier or read cache, not both.
  • MSA-DP+ spares: the spare capacity is distributed, not a separate spare drive.
  • Two pools maximum: one per controller.
Loading diagram...
MSA Gen7 virtual storage and tiering
Test Your Knowledge

An HPE MSA 2070 has HDD disk groups in pool A and an SSD flash pool in pool B. The customer has not bought the Advanced Data Services Suite. What is the licensing position?

A

No license is needed, because the SSDs are placed in a different pool

B

An ADS license is required, because SSDs and HDDs are mixed and the SSDs are not read cache

C

No license is needed, because the 10K HDDs are in the archive tier

D

A Remote Snap license is required instead of the ADS Suite license

Test Your Knowledge

Which statement best describes MSA-DP+?

A

A RAID level that uses one dedicated hot-spare drive for every eight data drives in the group

B

A RAID 0 stripe that the MSA uses only for SSD read cache

C

A mirroring scheme that requires drives of identical capacity in pairs

D

Erasure-coded RAID with parity and spare capacity spread across all drives

Test Your Knowledge

A customer wants faster reads for an HDD pool but cannot buy the Advanced Data Services Suite and is worried about losing data if an SSD fails. Which MSA feature fits?

A

SSD read cache holding copies of hot data

B

A performance tier built from a single SSD in RAID 0 to save cost

C

Remote Snap replication to a second MSA array

D

Volume Copy of the HDD volumes to an SSD flash pool

Test Your Knowledge

A backup-copy volume on an MSA with automated tiering keeps consuming SSD capacity during restore tests. Which setting reduces this without disabling tiering for the whole array?

A

Delete pool B

B

Disable thin provisioning

C

Set the volume's tier affinity to Archive

D

Change the disk group from MSA-DP+ to RAID 10