100+ Free NV C-1G Gas Pipes and Vents Practice Questions
Prepare for the Nevada C-1G Pipes and Vents for Gas Contractor Examination exam with instant access — no signup required.
Loading practice questions...
Explore More Nevada NSCB Contractor Examinations
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
Key Facts: NV C-1G Gas Pipes and Vents Exam
50 Q
Official Exam Questions
PSI Nevada Contractor CIB updated 3/25/2026
70%
Passing Score
PSI Nevada Contractor CIB updated 3/25/2026
2 hours
Time Allowed
PSI Nevada Contractor CIB updated 3/25/2026
USD 95
PSI Exam Fee (one portion)
PSI Nevada Contractor CIB updated 3/25/2026
Open Book
Book Policy
PSI Nevada Contractor CIB updated 3/25/2026
Nevada C-1G Pipes and Vents for Gas Contractor Examination is the official NSCB/PSI open book exam: 50 questions, 70% (35 of 50 points), 2 hours, USD 95 (bulletin 270, updated 3/25/2026). Official delivery: English.
Sample NV C-1G Gas Pipes and Vents Practice Questions
Try these sample questions to test your NV C-1G Gas Pipes and Vents exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.
1Per NFPA 54 2012, the point of delivery for a natural-gas piping system (other than undiluted LP-gas) is which of the following?
2The NFPA 54 2012 and UMC 2018 Schedule 40 metallic-pipe sizing tables for natural gas are based on which specific gravity?
3Unless a listed outdoor-appliance exception applies, underground fuel-gas piping shall be installed with a minimum cover of which depth?
4An approved individual underground line serving only an outdoor grill, gas light, or similar outdoor appliance, in a location not subject to physical damage, may be installed with a minimum cover of:
5Polyethylene (PE) plastic fuel-gas pipe is permitted in which of the following locations?
6An underground nonmetallic fuel-gas pipe shall have a tracer that is not smaller than which of the following?
7Which statement about corrosion protection of underground steel fuel-gas piping is correct under NFPA 54 2012 / UMC 2018?
8A yellow-jacket CSST natural-gas piping system installed in a building shall be bonded to the electrical-service grounding electrode system with a jumper not smaller than:
9Which of the following uses of metallic fuel-gas piping is prohibited?
10Each gas appliance shall have an accessible approved manual shutoff valve in the same room and within what maximum distance of the appliance, installed upstream of any connector?
About the NV C-1G Gas Pipes and Vents Exam
The Nevada C-1G Pipes and Vents for Gas Contractor Examination is the official Nevada State Contractors Board trade or management examination administered by PSI Services LLC. The official exam has 50 scored questions. Passing is 70% (35 of 50 points) in 2 hours. The examination is open book. Approved center references include UMC 2018 and NFPA 54 (2012) (allowed in center). PSI lists USD 95 for one examination portion and USD 140 if taken with CMS; otherwise USD 95 per trade exam (Candidate Information Bulletin updated 3/25/2026). NSCB requires a separate CMS examination for most new applicants, plus a USD 300 application fee and a USD 600 biennial license fee. This English-language MCQ bank is a study aid, not an official PSI form. It does not replace required trade experience, board approval, fingerprints, bonding, or the official examination.
Assessment
Open Book computer-based multiple-choice. UMC 2018 and NFPA 54 (2012) (allowed in center)
Time Limit
2 hours
Passing Score
70% (35 of 50 points)
Exam Fee
USD 95 (PSI Services LLC (for the Nevada State Contractors Board))
NV C-1G Gas Pipes and Vents Exam Content Outline
Natural Gas Piping
Natural-gas piping (12 items)
LP Gas Piping
LP-gas piping (12 items)
Chimneys, Flues and Vents
Chimneys, flues, and vents (10 items)
Appliance Installation
Gas appliance installation (5 items)
Sizing and Estimating
Pipe sizing and estimating (5 items)
Testing and Inspection
Testing and inspection (3 items)
Combustion Air
Combustion air (3 items)
How to Pass the NV C-1G Gas Pipes and Vents Exam
What You Need to Know
- Passing score: 70% (35 of 50 points)
- Assessment: Open Book computer-based multiple-choice. UMC 2018 and NFPA 54 (2012) (allowed in center)
- Time limit: 2 hours
- Exam fee: USD 95
Keys to Passing
- Work through all 100 available questions
- Review every answer and explanation
- Track weak areas and revisit them
- Use our AI tutor for tough concepts
NV C-1G Gas Pipes and Vents Study Tips from Top Performers
Frequently Asked Questions
How many questions are on the Nevada C-1G Pipes and Vents for Gas Contractor Examination?
The official PSI examination has 50 scored questions. Passing is 70% (35 of 50 points) within 2 hours (Candidate Information Bulletin 270, updated 3/25/2026).
How much does the NV C-1G Gas Pipes and Vents exam cost?
PSI lists USD 95 for one examination portion. Two portions cost USD 140 only if the second portion is CMS. NSCB charges a separate USD 300 application fee and USD 600 biennial license fee.
Is the NV C-1G Gas Pipes and Vents exam open book?
Yes. PSI lists this examination as open book. UMC 2018 and NFPA 54 (2012) (allowed in center)
Do I still need the CMS examination?
CMS is the required Nevada business-and-law examination. Most new applicants must pass CMS and a trade examination for the requested classification. In most cases you will not retake an exam if you have actively served as a qualified employee in the same classification within the last four years.