All Practice Exams

100+ Free NV A-10 Pools Practice Questions

Prepare for the Nevada A-10 Commercial and Residential Pools Contractor Examination exam with instant access — no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
100+ Questions
100% Free

Loading practice questions...

2026 Statistics

Key Facts: NV A-10 Pools Exam

75 Q

Official Exam Questions

PSI Nevada Contractor CIB updated 3/25/2026

53 of 75 points

Passing Score

PSI Nevada Contractor CIB updated 3/25/2026

2.5 hours

Time Allowed

PSI Nevada Contractor CIB updated 3/25/2026

USD 95

PSI Exam Fee (one portion)

PSI Nevada Contractor CIB updated 3/25/2026

Open Book

Book Policy

PSI Nevada Contractor CIB updated 3/25/2026

Nevada A-10 Commercial and Residential Pools Contractor Examination is the official NSCB/PSI open book exam: 75 questions, 53 of 75 points, 2.5 hours, USD 95 (bulletin 291, updated 3/25/2026). Official delivery: English.

Sample NV A-10 Pools Practice Questions

Try these sample questions to test your NV A-10 Pools exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1A rectangular public pool is 40 ft long by 20 ft wide with a uniform 5 ft water depth. Using 7.48 gal/ft³, what design flow is required for a 6-hour turnover?
A.83 gpm
B.67 gpm
C.100 gpm
D.125 gpm
Explanation: Volume = 40 × 20 × 5 × 7.48 = 29,920 gallons. Required flow = gallons ÷ (turnover hours × 60) = 29,920 ÷ 360 = 83.1 gpm. ANSI/APSP/ICC-1 2014 Table 8.1.1 caps Class A, B, and C pool turnover at 6 hours, so 83 gpm is the 6-hour design flow.
2A commercial pool holds 54,000 gallons and the circulation pump delivers 150 gpm with a clean filter. What is the turnover time?
A.4.0 hours
B.6.0 hours
C.8.0 hours
D.3.0 hours
Explanation: Turnover time in hours equals pool volume in gallons divided by flow in gpm times 60. Here 54,000 ÷ (150 × 60) = 54,000 ÷ 9,000 = 6.0 hours. That matches the ANSI/APSP/ICC-1 2014 Table 8.1.1 maximum of 6 hours for Class A, B, and C pools.
3Per ANSI/APSP/ICC-1 2014 Section 8.2, the water velocity in public-pool suction piping shall not exceed which value?
A.10 feet per second
B.8 feet per second
C.6 feet per second
D.3 feet per second
Explanation: APSP-1 2014 Section 8.2 limits suction piping to 6 fps and discharge piping to 10 fps, except copper discharge, which is limited to 8 fps. Keeping suction velocity at or below 6 fps reduces friction loss, cavitation risk, and suction-outlet loading.
4A public-pool return line is Type L copper. Per ANSI/APSP/ICC-1 2014 Section 8.2, what is the maximum permitted water velocity in that discharge piping?
A.12 feet per second
B.6 feet per second
C.10 feet per second
D.8 feet per second
Explanation: Section 8.2 allows 10 fps in discharge piping except copper, which is limited to 8 fps to reduce erosion-corrosion of the softer metal. Suction piping remains limited to 6 fps regardless of material.
5A public pool requires 120 gpm at the 6-hour turnover. Using a high-rate sand filter media rate of 15 gpm/ft² (NSF/ANSI 50 practice referenced by APSP-1 Section 9), what minimum filter area is required?
A.8.0 square feet
B.6.0 square feet
C.12.0 square feet
D.15.0 square feet
Explanation: Filter area = design flow ÷ media rate = 120 gpm ÷ 15 gpm/ft² = 8.0 ft². APSP-1 Section 9 requires filters to comply with NSF/ANSI 50 and not exceed the listed maximum flow of the media. Undersizing the area forces the filter above its NSF rating.
6A spa circulation system is designed for 80 gpm. Using a pressure diatomaceous-earth (DE) media rate of 2.0 gpm/ft², what minimum filter area is required?
A.16 square feet
B.40 square feet
C.80 square feet
D.20 square feet
Explanation: Area = 80 gpm ÷ 2.0 gpm/ft² = 40 ft². DE filters are listed under NSF/ANSI 50 at about 2 gpm/ft² for pressure units, so they need much more area than high-rate sand for the same flow.
7A pool filter system must handle 75 gpm. Using a cartridge media rate of 0.375 gpm/ft², what minimum cartridge area is required?
A.75 square feet
B.100 square feet
C.200 square feet
D.300 square feet
Explanation: Area = 75 ÷ 0.375 = 200 ft². Cartridge elements are rated far lower per square foot than sand, so a modest flow still needs a large listed area. NSF/ANSI 50 listings, which APSP-1 Section 9 requires filters to meet, commonly use 0.375 gpm/ft² for residential/commercial cartridge ratings.
8Per ANSI/APSP/ICC-1 2014 Section 12.3, when automatic surface skimmers are the sole overflow system, at least one skimmer is required for each how many square feet of water surface?
A.1,000 square feet
B.300 square feet
C.800 square feet
D.500 square feet
Explanation: Section 12.3 requires at least one surface skimmer per 500 sq ft, or fraction thereof, of water surface. Recessed stairs, swimouts, and spas are excluded from that area. Skimmers must also be located so they actually skim.
9Per ANSI/APSP/ICC-1 2014 Section 11.6, the number of return inlets shall be based on a minimum of one return inlet per how much pool surface area?
A.300 square feet
B.500 square feet
C.150 square feet
D.1,000 square feet
Explanation: Section 11.6 requires at least one return inlet per 300 sq ft of pool surface, or fraction thereof. Inlets must be sized or numerous enough to pass the full turnover flow and arranged for uniform circulation and sanitizer distribution.
10A new public pool suction outlet (other than a skimmer) must have a cover tested to which standard, as required by ANSI/APSP/ICC-1 2014 Section 11.2 and the Virginia Graeme Baker Pool and Spa Safety Act?
A.ANSI/NSF 14
B.ANSI/APSP-16
C.ASTM F1346
D.ANSI Z21.56
Explanation: APSP-1 Section 11.2 requires suction-outlet covers (other than skimmers) to be tested to ANSI/APSP-16 by an ILAC-accredited lab. VGBA likewise requires listed unblockable or dual-drain fittings. APSP/ICC-7 governs the piping arrangement that prevents entrapment.

About the NV A-10 Pools Exam

The Nevada A-10 Commercial and Residential Pools Contractor Examination is the official Nevada State Contractors Board trade or management examination administered by PSI Services LLC. The official exam has 75 scored questions. Passing is 53 of 75 points in 2.5 hours. The examination is open book. Approved center references include Uniform Swimming Pool, Spa and Hot Tub Code, 2018 (IAPMO). PSI lists USD 95 for one examination portion and USD 140 if taken with CMS; otherwise USD 95 per trade exam (Candidate Information Bulletin updated 3/25/2026). NSCB requires a separate CMS examination for most new applicants, plus a USD 300 application fee and a USD 600 biennial license fee. This English-language MCQ bank is a study aid, not an official PSI form. It does not replace required trade experience, board approval, fingerprints, bonding, or the official examination.

Assessment

Open Book computer-based multiple-choice. Uniform Swimming Pool, Spa and Hot Tub Code, 2018 (IAPMO)

Time Limit

2.5 hours

Passing Score

53 of 75 points

Exam Fee

USD 95 (PSI Services LLC (for the Nevada State Contractors Board))

NV A-10 Pools Exam Content Outline

16%

Filtration/Circulation Systems

Pumps, filters, and circulation (12 items)

16%

Maintenance and Operation

Pool and spa operation (12 items)

11%

Accessories and Associated Trades

Decks, heaters, and related trades (8 items)

4%

Pool and Spa Business Laws and Rules

Nevada pool contracting rules (3 items)

20%

Concrete, Shotcrete and Gunite

Structural shell construction (15 items)

21%

Design

Pool and spa design (16 items)

12%

Soils and Earthwork

Soils and excavation (9 items)

How to Pass the NV A-10 Pools Exam

What You Need to Know

  • Passing score: 53 of 75 points
  • Assessment: Open Book computer-based multiple-choice. Uniform Swimming Pool, Spa and Hot Tub Code, 2018 (IAPMO)
  • Time limit: 2.5 hours
  • Exam fee: USD 95

Keys to Passing

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

NV A-10 Pools Study Tips from Top Performers

1Distribute study time to the official bulletin 291 content outline (updated 3/25/2026)
2Use only the PSI-listed references; temporary tabs such as Post-it notes are prohibited
3Confirm NSCB experience documentation before scheduling with PSI
4This bank is an English-language MCQ study aid, not an official PSI form

Frequently Asked Questions

How many questions are on the Nevada A-10 Commercial and Residential Pools Contractor Examination?

The official PSI examination has 75 scored questions. Passing is 53 of 75 points within 2.5 hours (Candidate Information Bulletin 291, updated 3/25/2026).

How much does the NV A-10 Pools exam cost?

PSI lists USD 95 for one examination portion. Two portions cost USD 140 only if the second portion is CMS. NSCB charges a separate USD 300 application fee and USD 600 biennial license fee.

Is the NV A-10 Pools exam open book?

Yes. PSI lists this examination as open book. Uniform Swimming Pool, Spa and Hot Tub Code, 2018 (IAPMO)

Do I still need the CMS examination?

CMS is the required Nevada business-and-law examination. Most new applicants must pass CMS and a trade examination for the requested classification. In most cases you will not retake an exam if you have actively served as a qualified employee in the same classification within the last four years.