100+ Free TN Electrician Practice Questions

Pass your Tennessee Limited Licensed Electrician (LLE) Exam exam on the first try — instant access, no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
~55% Pass Rate
100+ Questions
100% Free
1 / 100
Question 1
Score: 0/0

According to the NEC, what is the definition of a 'branch circuit'?

A
B
C
D
to track
2026 Statistics

Key Facts: TN Electrician Exam

70%

Passing Score

TN Board for Licensing Contractors

~80

Exam Questions

PSI

4 hrs

Time Limit

PSI

$57

Exam Fee

PSI

The TN Limited Licensed Electrician (LLE) exam requires 70% to pass across approximately 80 multiple-choice questions in 4 hours. It is open-book, allowing a bound copy of the 2017 NEC. The exam fee is $57. Tennessee uses the unique title 'Limited Licensed Electrician' for journeyman-level licensure through the Board for Licensing Contractors.

Sample TN Electrician Practice Questions

Try these sample questions to test your TN Electrician exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1According to the NEC, what is the definition of a 'branch circuit'?
A.The circuit conductors between the service point and the main disconnecting means
B.The circuit conductors between the final overcurrent device protecting the circuit and the outlet(s)
C.Any circuit that supplies power to a motor
D.The conductors between the transformer and the first overcurrent device
Explanation: Per NEC Article 100, a branch circuit is defined as the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). This definition is fundamental to understanding how the NEC organizes and regulates different parts of an electrical system.
2Tennessee uses the Board for Licensing Contractors for electrician licensing. What NEC edition does Tennessee currently use for the Limited Licensed Electrician (LLE) exam?
A.NEC 2014
B.NEC 2017
C.NEC 2020
D.NEC 2023
Explanation: Tennessee currently uses the 2017 NEC for the Limited Licensed Electrician (LLE) exam. Tennessee has been slower to adopt newer NEC editions compared to many states. The Board for Licensing Contractors oversees the licensing program.
3Per NEC 210.8(A), GFCI protection is required for all 125-volt through 250-volt receptacles in which of the following dwelling unit locations?
A.Living rooms
B.Bedrooms
C.Kitchens
D.Closets
Explanation: NEC 210.8(A) requires GFCI protection for 125-volt through 250-volt receptacles in dwelling unit kitchens, along with bathrooms, garages, outdoors, crawl spaces, basements, and other specified locations. The 2023 NEC expanded GFCI requirements significantly.
4What is the minimum size equipment grounding conductor required for a 60-ampere circuit per NEC Table 250.122?
A.14 AWG copper
B.12 AWG copper
C.10 AWG copper
D.8 AWG copper
Explanation: Per NEC Table 250.122, a 60-ampere overcurrent device requires a minimum 10 AWG copper equipment grounding conductor. This table is based on the rating of the overcurrent device protecting the circuit, not the conductor ampacity.
5According to NEC 250.66, what is the minimum size grounding electrode conductor for a 2/0 AWG copper service conductor?
A.8 AWG copper
B.6 AWG copper
C.4 AWG copper
D.2 AWG copper
Explanation: Per NEC Table 250.66, for service conductors sized 2/0 AWG copper (or 4/0 AWG aluminum), the minimum grounding electrode conductor is 4 AWG copper or 2 AWG aluminum. This table correlates the size of the largest service-entrance conductor with the required grounding electrode conductor.
6What is the standard voltage drop recommendation for branch circuits per NEC 210.19(A) Informational Note No. 4?
A.2%
B.3%
C.5%
D.8%
Explanation: NEC 210.19(A) Informational Note No. 4 recommends that voltage drop on branch circuits should not exceed 3%, and the total voltage drop for feeders and branch circuits combined should not exceed 5%. While these are recommendations rather than requirements, they represent good practice.
7Per NEC Table 310.16, what is the ampacity of a 6 AWG THWN-2 copper conductor at 75°C column?
A.40 amperes
B.55 amperes
C.65 amperes
D.75 amperes
Explanation: Per NEC Table 310.16, a 6 AWG copper conductor with a 75°C insulation rating (such as THWN-2 used at 75°C) has an ampacity of 65 amperes. THWN-2 is rated for 90°C but is commonly used at the 75°C column when terminated at equipment rated for 75°C.
8According to NEC 314.16(B), what is the volume allowance for each 12 AWG conductor in a box fill calculation?
A.2.00 cubic inches
B.2.25 cubic inches
C.2.50 cubic inches
D.3.00 cubic inches
Explanation: Per NEC Table 314.16(B), each 12 AWG conductor requires a volume allowance of 2.25 cubic inches in a box fill calculation. This includes equipment grounding conductors counted as one conductor, device yokes counted as two conductors, and clamps counted as one conductor.
9Per NEC 430.52, what is the maximum size dual-element time-delay fuse permitted for motor branch-circuit short-circuit and ground-fault protection for a standard AC motor?
A.125% of motor FLC
B.150% of motor FLC
C.175% of motor FLC
D.250% of motor FLC
Explanation: Per NEC Table 430.52, the maximum rating for a dual-element time-delay fuse used for motor branch-circuit short-circuit and ground-fault protection is 175% of the motor's full-load current. If 175% does not correspond to a standard fuse size, the next higher standard size may be used.
10What is the minimum height above grade for service drop conductors over a residential driveway?
A.10 feet
B.12 feet
C.15 feet
D.18 feet
Explanation: Per NEC 230.24(B)(1), service drop conductors must maintain a minimum clearance of 12 feet above residential driveways and commercial areas not subject to truck traffic. This clearance ensures safe passage of vehicles beneath the conductors.

About the TN Electrician Exam

The Tennessee Limited Licensed Electrician (LLE) exam is administered by PSI for the TN Board for Licensing Contractors. Based on the 2017 NEC, it covers electrical theory, code compliance, grounding and bonding, wiring methods, load calculations, motors, transformers, and special occupancies. Tennessee uses 'Limited Licensed Electrician' (LLE) as the journeyman-level title.

Questions

80 scored questions

Time Limit

4 hours

Passing Score

70%

Exam Fee

$57 (TN Board for Licensing Contractors / PSI)

TN Electrician Exam Content Outline

20%

NEC General & Theory

Definitions, electrical theory, NEC navigation, working space requirements, and installation fundamentals

20%

Branch Circuits & Overcurrent Protection

Circuit sizing, receptacle spacing, GFCI/AFCI requirements, overcurrent protection, and lighting outlets

15%

Grounding & Bonding

Grounding electrode systems, equipment grounding, bonding requirements, and ground-fault protection

20%

Wiring Methods & Materials

Conductor ampacity, conduit fill, cable assemblies, box fill calculations, and raceway types

25%

Services, Feeders, Motors & Special Occupancies

Service entrance requirements, load calculations, motor circuits, transformers, hazardous locations, and healthcare facilities

How to Pass the TN Electrician Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 80 questions
  • Time limit: 4 hours
  • Exam fee: $57

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

TN Electrician Study Tips from Top Performers

1Study the 2017 NEC specifically — Tennessee has not adopted newer editions, and some requirements differ
2Master NEC Article 250 (Grounding and Bonding) — heavily tested on every state exam
3Practice dwelling unit load calculations using Article 220 of the 2017 NEC
4Focus on conductor ampacity from Table 310.15(B)(16) in the 2017 NEC (renumbered from 2014)
5Study motor circuits (Article 430) and HVAC compressor requirements (Article 440)

Frequently Asked Questions

What is the Tennessee LLE license?

The Limited Licensed Electrician (LLE) is Tennessee's journeyman-level electrical license. It allows you to perform electrical work under the supervision of a licensed electrical contractor. The LLE exam is administered by PSI for the TN Board for Licensing Contractors.

What NEC edition does Tennessee use for the LLE exam?

Tennessee currently uses the 2017 NEC for the LLE exam. Tennessee has been slower to adopt newer NEC editions. Study the 2017 NEC specifically, as some code requirements differ from the 2020 and 2023 editions.

How hard is the Tennessee LLE exam?

The exam is challenging with an estimated 55% first-time pass rate. It covers approximately 80 questions in 4 hours. Mastery of NEC navigation and load calculations is essential.

How much does the Tennessee LLE exam cost?

The exam fee is $57 through PSI. Additional costs include the 2017 NEC codebook and study materials. Apply through the TN Board for Licensing Contractors before scheduling.