All Practice Exams

100+ Free Malersvendeprøven Practice Questions

Prepare for the Bygningsmaler Svendeprøve (Painter Journeyman) (Denmark) exam with instant access — no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
100+ Questions
100% Free

Loading practice questions...

2026 Statistics

Key Facts: Malersvendeprøven Exam

Level 4

Qualification level in the Danish Qualifications Framework

BEK nr. 196 af 28/01/2026

8 days

Practical booth assessment duration in the final school period

MFFU Svendeprøveregler

10 disciplines

Evaluated practical craft tasks in the svendeprøve booth

MFFU Censorvejledning

DKK 5,500

Employer-paid registration fee to the trade committee

MFFU tilmeldingsbetingelser

Grade 02

Minimum passing grade required on the 7-trinsskalaen

BEK nr. 196/2026 § 23

MFFU's Bygningsmaler svendeprøve is an 8-day practical booth assessment of 10 craft disciplines covering surface preparation, skim-coating, paint systems, wallpapering, and chemical safety.

Sample Malersvendeprøven Practice Questions

Try these sample questions to test your Malersvendeprøven exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1According to Danish trade standards for drywall finishing, what is the defining requirement for surface quality class K1 (spartling klasse K1)?
A.Basic joint filling where drywall joints are embedded with reinforcement tape and screw heads are covered, with no requirement for visual appearance
B.Standard commercial filling where joints and screw heads are filled and sanded flush, suitable for medium-textured wallpapers
C.Higher-grade filling where joints are widened and the entire surface is primed for smooth non-woven fleece (glasfilt)
D.Continuous skim-coat covering 100% of the gypsum board surface to eliminate all joint textures under grazing light (strejflys)
Explanation: Quality class K1 represents basic joint treatment (grundspartling/forskæring). The drywall joints are filled, reinforcement tape (armeringsbånd) is embedded, and fasteners are filled, but surface smoothness and optical uniformity are not evaluated since K1 is only used under thick tiles or structural cladding.
2When a project specification calls for the highest full-surface preparation class beneath smooth glass fleece in critical raking light, which class is intended?
A.Class K1
B.Class K2
C.Class K3
D.Class K4
Explanation: K4 denotes the highest full-surface preparation level in the referenced Danish finishing scheme and is the intended answer when that level is specified for a critically lit smooth finish. The required class must come from the project specification and agreed viewing conditions; the wallcovering name alone does not make K4 universally mandatory.
3When inspecting an existing plastered ceiling before painting, a painter wipes a dark cloth across the dry surface and observes significant chalking (afsmittende flade). What is the mandatory bundbehandling before applying emulsion paint?
A.Apply two heavy coats of high-build dispersion paint directly to bind the loose dust
B.Wash with an acidic detergent (eddikesyre) and immediately apply wall adhesive
C.Brush off loose particles and apply a penetrating acrylic primer (forankringsgrund / mikrodispers)
D.Sand the surface with 40-grit sandpaper and skim with unthinned gypsum plaster
Explanation: Chalking and crumbly mineral substrates must be cleaned of loose particles and consolidated with a penetrating primer (forankringsgrund or mikrodispers). The fine acrylic particles penetrate deep into the porous substrate, binding free particles and equalizing absorption.
4White crystalline salt deposits (saltudslag / efflorescence) are observed on an interior brick wall in an older building. What is the correct trade procedure to remediate this substrate?
A.Wash thoroughly with hot water and soap, then seal the wet wall immediately with polyurethane enamel
B.Brush off the dry crystals with a stiff non-metallic brush, locate and eliminate the moisture source, and allow the wall to dry completely before finishing
C.Apply an impervious bitumen primer directly over the crystals to trap the salts within the masonry
D.Scrape out all mortar joints to a depth of 50 mm and fill flush with lightweight dispersion filler
Explanation: Efflorescence occurs when water migrates through masonry, dissolves mineral salts, and evaporates at the surface. Washing with water re-dissolves the salts and drives them deeper, causing recurring damage; the salts must be brushed off dry, the water ingress fixed, and the wall dried before breathable mineral or masonry coatings are applied.
5A painter must prepare newly cast concrete walls before skimming. What surface condition must be identified and removed before any primer or filler is applied?
A.Carbonation layer (karbonatisering)
B.Form-release oil residue and cement laitance (støbeskalslag / formsæberester)
C.Micro-cracks measuring less than 0.1 mm
D.Aggregate exposure from coarse sand
Explanation: Form release agents (formsæbe/formolie) and weak cement laitance (støbeskalslag/glimmerlag) on new concrete severely impair adhesion. They must be removed by degreasing, high-pressure washing, mechanical grinding, or light abrasive blast-cleaning before priming and skimming.
6What is the key chemical and physical difference between ready-mixed dispersion filler (sandspartel / dispersionsspartel) and powder-based gypsum filler (gipsbaseret spartelmasse)?
A.Dispersion filler dries solely by water evaporation accompanied by volume shrinkage, while gypsum filler hardens by chemical hydration with minimal shrinkage
B.Gypsum filler cures exclusively by atmospheric carbonation, whereas dispersion filler cures by oxidation
C.Dispersion filler hardens in any layer thickness without drying cracks, while gypsum filler is limited to 1 mm coats
D.Gypsum filler is highly flexible and waterproof, whereas dispersion filler is rigid and water-soluble
Explanation: Ready-mixed dispersion fillers dry physically through evaporation of water, leading to noticeable volume shrinkage when applied in thick layers. Gypsum-based fillers (pulverbaseret gipsspartel) cure chemically by binding water into calcium sulfate dihydrate crystals, curing rapidly with virtually zero shrinkage even in deep depressions.
7For a gypsum-board jointing system that specifies paper reinforcement in tapered joints, which material should be embedded in the wet joint compound?
A.Self-adhesive fiberglass mesh tape (selvklæbende glasfibernet)
B.Creped masking tape (afdækningstape)
C.Paper joint tape (papirarmeringsbånd) embedded into wet joint compound
D.Polyester fleece cut into 200 mm strips
Explanation: Paper joint tape is embedded in the wet compound in systems designed around paper reinforcement and provides strong crack resistance when installed correctly. The candidate must follow the complete tested board-and-compound system; no tape can guarantee a crack-free joint if framing movement, board fixing, gaps, or drying are wrong.
8A wall surface exhibits nicotine, dried soot, and localized water stains. What will occur if this substrate is coated directly with standard water-borne acrylic wall paint?
A.The acrylic paint will dissolve the wall plaster and cause rapid spalling
B.Water-soluble tar and stain components will bleed through (gennemslag) into the wet paint film and discolor the dried surface
C.The paint will immediately flash-cure and form a glass-like brittle skin
D.The stains will turn completely white and blend invisibly with the emulsion
Explanation: Nicotine, soot, and dried water rings contain water-soluble contaminants. Water-borne dispersion paints re-wet these substances, causing them to migrate into the liquid film (gennemslag) and reappear as yellowish-brown stains upon drying. A dedicated barrier/stain-blocking primer (spærregrund / isolérgrund) is required.
9Which type of primer is technically designated to prevent bleed-through (gennemslag) of knot resins, nicotine, and dry water damage?
A.Diluted clear acrylic mikrodispers
B.Water-thinned potassium silicate primer (silikatgrunder)
C.Isolating barrier primer (spærregrund / knast- og spærrelak)
D.High-alkaline cement wash
Explanation: Spærregrund (barrier primer) is formulated with specialized blocking polymers (or cationic shellac/alkyd resins) that form a tight, impermeable film, preventing water- and solvent-soluble tannins, nicotine, and resins from bleeding into topcoats.
10A painter must skim-coat a room with a total wall surface area of 84 m² to quality class K4 using a lightweight roller-applied skim filler (rullespartel). The manufacturer specifies a coverage of 1.2 liters per m² for a 1 mm continuous layer. How many liters of rullespartel are required?
A.70.0 liters
B.100.8 liters
C.120.5 liters
D.84.0 liters
Explanation: Calculate material consumption: Volume = Area × Application Rate = 84 m² × 1.2 L/m² = 100.8 liters of filler.

About the Malersvendeprøven Exam

Bygningsmaler Svendeprøve is the statutory trade examination concluding the apprenticeship for building painters in Denmark, regulated by BEK nr. 196/2026. The 8-day examination in an individual booth assesses 10 distinct craft disciplines: substrate diagnosis, filling to standard quality classes (K1–K4), wallpaper and fiberglass hanging, fine woodworking finishes, color matching via the Natural Colour System (NCS), exterior protection, and strict chemical safety under Denmark's MAL-code system and epoxy rules. Skuemestre from Malerforbundet and Danske Malermestre evaluate precision, surface smoothness, covering power, and work hygiene. This study bank reinforces paint chemistry, technical standards, coverage calculations, and safety compliance.

Assessment

Under BEK nr. 196/2026 and MFFU guidelines, the 8-day practical svendeprøve takes place in an allocated work booth. The apprentice completes 10 specified disciplines covering substrate cleaning, filler skimming, lining paper/wallpaper hanging, door/trim painting, wall rolling, decorative techniques, and job calculation, assessed by a commission of skuemestre on day 9.

Time Limit

8 workdays including introduction, normally 08:00–16:00, followed by 1 assessment day and a 5-minute oral presentation.

Passing Score

At least 400 total points, corresponding to grade 02 on the published MFFU scale; every one of the 10 tasks must be started.

Exam Fee

No candidate-paid fee; the apprentice's training company pays a registration fee of DKK 5,500 to Malerfagets Faglige Fællesudvalg (MFFU). (Approved technical colleges and Malerfagets Faglige Fællesudvalg (MFFU))

Malersvendeprøven Exam Content Outline

25 questions

Substrate Diagnosis & Skim-Coating

Moisture assessment, substrate adhesion, primers, joint taping, and surface finish classes K1 to K4.

25 questions

Paint Chemistry & Surface Systems

Emulsion and alkyd paints, binder ratios, pigment volume concentration (PVC), coverage rates, and sheen levels.

15 questions

Wall Coverings & Wallpapering

Glass fiber tissue, smooth lining fleece, patterned wallpapers, paste types, pattern matching, and seam butt-joints.

15 questions

NCS Color Theory & Decorative Crafts

The Natural Colour System notation, contrast ratios, glaze coats, masking crisp lines, and decorative finishes.

10 questions

Wood Preservation & Metal Primers

Moisture thresholds in exterior joinery, rot prevention, anti-corrosion barrier primers, and intermediate enamel coats.

10 questions

MAL-Codes & Workplace Safety

Danish MAL-code numbers, organic solvent exposure, respiratory protection, epoxy rules, and dust extraction.

How to Pass the Malersvendeprøven Exam

What You Need to Know

  • Passing score: At least 400 total points, corresponding to grade 02 on the published MFFU scale; every one of the 10 tasks must be started.
  • Assessment: Under BEK nr. 196/2026 and MFFU guidelines, the 8-day practical svendeprøve takes place in an allocated work booth. The apprentice completes 10 specified disciplines covering substrate cleaning, filler skimming, lining paper/wallpaper hanging, door/trim painting, wall rolling, decorative techniques, and job calculation, assessed by a commission of skuemestre on day 9.
  • Time limit: 8 workdays including introduction, normally 08:00–16:00, followed by 1 assessment day and a 5-minute oral presentation.
  • Exam fee: No candidate-paid fee; the apprentice's training company pays a registration fee of DKK 5,500 to Malerfagets Faglige Fællesudvalg (MFFU).

Keys to Passing

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

Malersvendeprøven Study Tips from Top Performers

1Practice coverage and consumption calculations: Paint Needed (L) = (Area m² × Coats) ÷ Spreading Rate (m²/L).
2Learn to interpret NCS color codes quickly (e.g., in S 2030-Y90R: 20% blackness, 30% chromaticness, yellow with 90% red).
3Memorize MAL-code requirements: products with solvent numbers above 00 require specific mechanical ventilation or respiratory air-fed masks for indoor use.
4Understand the critical differences between dispersion fillers, plaster-based setting compounds, and epoxy repair mortars regarding shrinkage and drying time.

Frequently Asked Questions

Is the Bygningsmaler Svendeprøve a written multiple-choice test?

No. The official exam is an 8-day practical test conducted in an allocated workshop booth where the candidate completes 10 specified painting and surface tasks, judged by two external skuemestre. This bank is an English-language MCQ study adaptation.

What is Denmark's MAL-code system in the painting trade?

The MAL-code (Måleteknisk Arbejdshygiejnisk Luftbehov) consists of two numbers (e.g., 00-1 or 2-3). The number before the hyphen indicates volatile solvent risk and required ventilation; the number after indicates skin and eye contact hazards.

What are the surface preparation classes used in Danish painting?

Standard skimming and filling follows classes K1 (basic joint filling), K2 (standard commercial finish), K3 (higher quality finish for smooth wall coverings), and K4 (premium continuous skim-coat for demanding lighting conditions).

What is the maximum moisture content allowed in wood before painting?

Under Danish trade guidelines, exterior wood must have a moisture content of no more than 15% (±3%) prior to the application of solvent-borne or water-borne paint systems.

How is the svendeprøve graded?

The examination commission grades the 10 task disciplines using the Danish 7-point scale (12, 10, 7, 4, 02, 00, -3). The candidate must achieve an overall passing average of at least 02.