All Practice Exams

100+ Free Bac F3 Burkina Faso Practice Questions

Prepare for the Baccalauréat Série F3 (Électrotechnique) — Burkina Faso exam with instant access — no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
100+ Questions
100% Free

Loading practice questions...

2026 Statistics

Key Facts: Bac F3 Burkina Faso Exam

2026 Schéma F3

Dedicated first-tour schema paper for Série F3

2026 national subject list

F1–F4 shared maths

2026 mathematics paper shared across industrial-tech series

2026 national subject list

Free 100-question English MCQ study bank for Bac F3 Burkina Faso. Official exam: French written electrotechnics, schema and maths papers plus practical work; pass on a 10/20 weighted average. Not a practical simulation.

Sample Bac F3 Burkina Faso Practice Questions

Try these sample questions to test your Bac F3 Burkina Faso exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1A resistive heater connected to a 12 V DC source draws current through a 24 ohm resistor. What is the current?
A.0.50 A
B.2.0 A
C.12 A
D.288 A
Explanation: Ohm's law states I = U/R. Substituting the given values gives I = 12 V / 24 ohm = 0.50 A. The result is a modest current consistent with a small DC heating resistor.
2Three resistors 10 ohm, 20 ohm and 30 ohm are connected in series. What is the equivalent resistance?
A.6.0 ohm
B.20 ohm
C.60 ohm
D.6000 ohm
Explanation: Series resistances add: Req = 10 + 20 + 30 = 60 ohm. The same current flows through each resistor, so their voltage drops add and the source sees the sum of the three values.
3Two 12 ohm resistors are connected in parallel. What is the equivalent resistance?
A.24 ohm
B.6.0 ohm
C.12 ohm
D.0.17 ohm
Explanation: For two equal resistors R in parallel, Req = R/2. Here Req = 12/2 = 6.0 ohm. Equivalently, 1/Req = 1/12 + 1/12 = 1/6, so Req = 6.0 ohm.
4A single-phase load on the 230 V SONABEL low-voltage network draws 2.0 A at unity power factor. What is the active power?
A.460 W
B.115 W
C.232 W
D.4600 W
Explanation: At unity power factor, P = U I. Therefore P = 230 V * 2.0 A = 460 W. Burkina Faso low-voltage single-phase supplies are 230 V at 50 Hz, so this is the standard BAC F3 power product.
5A 2.0 kW motor runs at constant load for 3.0 hours. How much electrical energy does it absorb if losses are neglected?
A.0.67 kWh
B.5.0 kWh
C.6.0 W
D.6.0 kWh
Explanation: Energy is power multiplied by time: W = P t. With P = 2.0 kW and t = 3.0 h, W = 6.0 kWh. The kilowatt-hour is the energy unit used on SONABEL invoices and in BAC F3 energy calculations.
6A node has one incoming current of 8.0 A and two outgoing currents of 3.0 A and 2.0 A. What is the third outgoing current if no charge accumulates at the node?
A.13 A
B.5.0 A
C.3.0 A
D.0 A
Explanation: Kirchhoff's current law states that the algebraic sum of currents at a node is zero. Incoming 8.0 A must equal 3.0 A + 2.0 A + I3, so I3 = 3.0 A. Charge cannot accumulate at an ideal node.
7A 12 V source feeds a series string of 2.0 kohm and 4.0 kohm. What is the voltage across the 4.0 kohm resistor?
A.4.0 V
B.6.0 V
C.8.0 V
D.12 V
Explanation: The voltage divider gives U4 = 12 * 4.0 / (2.0 + 4.0) = 12 * 4/6 = 8.0 V. The larger resistor takes two-thirds of the source voltage because the same current flows through both resistors.
8A 50 Hz sinusoidal voltage has a peak value of 325 V. What is its RMS value?
A.163 V
B.230 V
C.325 V
D.460 V
Explanation: For a sine wave, Urms = Up / sqrt(2). Then 325 / 1.414 = 230 V. This is the standard peak-to-RMS pair used for the 230 V, 50 Hz single-phase network taught in BAC F3.
9A sinusoidal waveform has a period T = 20 ms. What is its frequency?
A.20 Hz
B.50 Hz
C.60 Hz
D.500 Hz
Explanation: Frequency is the reciprocal of period: f = 1/T. With T = 20 ms = 0.020 s, f = 1/0.020 = 50 Hz. That is the SONABEL / West African grid frequency used throughout BAC F3 papers.
10A 24 V DC source feeds a 4.0 ohm resistor in series with the parallel combination of 6.0 ohm and 12 ohm. What current flows in the 6.0 ohm branch?
A.1.0 A
B.2.0 A
C.3.0 A
D.4.0 A
Explanation: The parallel pair 6.0 ohm || 12 ohm equals 4.0 ohm, so the total resistance is 4.0 + 4.0 = 8.0 ohm. Source current is 24/8.0 = 3.0 A and the voltage across the parallel pair is 3.0 * 4.0 = 12 V. The 6.0 ohm branch then carries 12/6.0 = 2.0 A.

About the Bac F3 Burkina Faso Exam

Série F3 is Burkina Faso's électrotechnique technical Baccalauréat. The 2026 session included a dedicated Schéma Série F3 first-tour paper and a shared F1–F4 mathematics paper. Official assessment mixes written French papers with schema and laboratory performance. This free English MCQ bank trains F3 circuit, machine and safety knowledge — it is not an official translation and cannot replace wiring or practical training.

Assessment

2026 national Schéma Série F3 paper, shared F1–F4 mathematics, specialty electrotechnics, general education, practical work and oral rachat. This bank is an English MCQ study adaptation only.

Time Limit

Multi-paper written session in the 2026 baccalauréat window, with industrial-tech deliberations reported in late July 2026.

Passing Score

Graded out of 20; awarded on a weighted average of at least 10/20, with oral rachat for close candidates.

Exam Fee

Not published as a per-candidate tariff; the 2026 session was state-organized. (MESFPT (Ministère de l'Enseignement Secondaire, de la Formation Professionnelle et Technique))

Bac F3 Burkina Faso Exam Content Outline

Study emphasis ~30%

Electrotechnics

DC/AC circuits, three-phase, transformers.

Study emphasis ~18%

Electrical machines

Asynchronous and DC machines.

Study emphasis ~14%

Electrical schema

2026 Schéma F3 paper.

Study emphasis ~12%

Electrical safety

Protection and earthing.

Study emphasis ~16%

Mathematics

Shared 2026 F1–F4 mathematics paper.

Study emphasis ~10%

French and workplace

French literacy and safety.

How to Pass the Bac F3 Burkina Faso Exam

What You Need to Know

  • Passing score: Graded out of 20; awarded on a weighted average of at least 10/20, with oral rachat for close candidates.
  • Assessment: 2026 national Schéma Série F3 paper, shared F1–F4 mathematics, specialty electrotechnics, general education, practical work and oral rachat. This bank is an English MCQ study adaptation only.
  • Time limit: Multi-paper written session in the 2026 baccalauréat window, with industrial-tech deliberations reported in late July 2026.
  • Exam fee: Not published as a per-candidate tariff; the 2026 session was state-organized.

Keys to Passing

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

Bac F3 Burkina Faso Study Tips from Top Performers

1Master Kirchhoff and three-phase power calculations.
2Practise reading unifilar and multifilar diagrams using standard symbols.
3Learn protection-device roles (breaker, differential, earthing) as a safety sequence.
4Work the shared F mathematics paper alongside specialty items.

Frequently Asked Questions

Was there a 2026 F3 schema paper?

Yes. A national Schéma Série F3 first-tour paper was set in 2026.

Can these MCQs replace the practical exam?

No. They train knowledge and diagram literacy only. Official F3 includes practical/schema performance.