A resistive heater connected to a 12 V DC source draws current through a 24 ohm resistor. What is the current?
Electrotechnics
Question · Easy
Same battery. Which lets more through?
Short
Three resistors 10 ohm, 20 ohm and 30 ohm are connected in series. What is the equivalent resistance?
Two 12 ohm resistors are connected in parallel. What is the equivalent resistance?
A single-phase load on the 230 V SONABEL low-voltage network draws 2.0 A at unity power factor. What is the active power?
A 2.0 kW motor runs at constant load for 3.0 hours. How much electrical energy does it absorb if losses are neglected?
A node has one incoming current of 8.0 A and two outgoing currents of 3.0 A and 2.0 A. What is the third outgoing current if no charge accumulates at the node?
A 12 V source feeds a series string of 2.0 kohm and 4.0 kohm. What is the voltage across the 4.0 kohm resistor?
A 50 Hz sinusoidal voltage has a peak value of 325 V. What is its RMS value?
A sinusoidal waveform has a period T = 20 ms. What is its frequency?
A 24 V DC source feeds a 4.0 ohm resistor in series with the parallel combination of 6.0 ohm and 12 ohm. What current flows in the 6.0 ohm branch?
Question · Medium
A series AC circuit has R = 30 ohm and XL = 40 ohm at 50 Hz. If the applied RMS voltage is 100 V, what is the RMS current?
For the same series RL circuit with R = 30 ohm and Z = 50 ohm, what is the lagging power factor?
A balanced three-phase load is supplied at UL = 400 V, IL = 10 A and cos phi = 0.80. Using sqrt(3) = 1.73, what is the active power?
Three identical 20 ohm windings are connected in delta on a 400 V three-phase line. What is the line current? Take sqrt(3) = 1.73.
A single-phase transformer is rated 10 kVA, 230 V on the secondary. What is the rated secondary current?
An ideal transformer has N1 = 1000 turns and N2 = 100 turns. If U1 = 230 V, what is U2?
What is the capacitive reactance of C = 100 microfarads at f = 50 Hz? Use 2*pi = 6.28.
A series RLC circuit has L = 0.10 H and C = 10 microfarads. What is the resonant frequency? Take 1/(2*pi) = 0.159.
A three-phase load absorbs P = 20 kW at cos phi1 = 0.60 lagging. Capacitors raise the power factor to cos phi2 = 0.90 lagging. What reactive power must the capacitors supply? Use tan phi1 = 1.333 and tan phi2 = 0.484.
A single-loop DC circuit contains a 10 V source and series resistors 2.0 ohm and 3.0 ohm. What is the loop current?
A load is rated S = 5.0 kVA at cos phi = 0.80 lagging. What are the active and reactive powers?
A cable with resistance 0.50 ohm carries 10 A. What is the Joule loss in the cable?
A node is connected to 20 V through 10 ohm, to 0 V through 20 ohm, and to 10 V through 5.0 ohm. What is the node voltage?
Question · Hard
A 50 kVA transformer has iron loss 400 W and full-load copper loss 800 W. It operates at 0.80 of rated apparent power with cos phi = 0.80. What is the efficiency?
A series RLC circuit is supplied at 230 V RMS with R = 40 ohm, XL = 80 ohm and XC = 50 ohm. What is the RMS current?
A three-phase asynchronous motor delivers 15 kW of mechanical power with efficiency 0.85 and cos phi = 0.80 on a 400 V line. What is the line current? Use sqrt(3) = 1.73.
A 10 kVA, 400 V transformer has a short-circuit voltage of 5.0%. What is the short-circuit impedance referred to that 400 V winding?
A Thevenin equivalent is Uth = 12 V in series with Rth = 4.0 ohm. What is the maximum power that can be delivered to a variable load RL?
A 100 microfarad capacitor is charged to 400 V. What energy is stored?
A 12 A current reaches a node and splits between 4.0 ohm and 8.0 ohm in parallel. What current flows in the 4.0 ohm resistor?
A three-phase 50 Hz induction motor has two pole pairs (four poles). What is its synchronous speed in revolutions per minute?
Electrical Machines
An induction motor has ns = 1500 r/min and runs at n = 1440 r/min. What is the slip?
Which DC machine connection is preferred when a very high starting torque is required, for example on a hoist?
What is the essential difference between a transformer and an asynchronous motor?
The rotor of a standard industrial squirrel-cage (cage d'ecureuil) induction motor is best described as:
A 50 Hz induction motor operates at slip g = 4.0%. What is the frequency of the rotor currents?
A DC generator delivers 20 A at 220 V. The armature resistance is 0.50 ohm (brushes included). What is the generated emf E?
A DC motor is supplied at 220 V and draws 20 A. Armature resistance is 0.40 ohm. What is the back emf E?
Compared with direct-on-line starting of a cage motor, star-delta (etoile-triangle) starting reduces the starting line current and the starting torque by what factor?
A motor runs at 1440 r/min and develops a shaft torque of 50 N.m. What is the mechanical power? Use 2*pi = 6.28.
On a DC machine nameplate sketch, the field winding is in parallel with the armature and there is no series field. The machine is:
What is the synchronous speed of a 50 Hz motor that has three pole pairs (six poles)?
An autotransformer starter is used on a cage motor with a 70% tapping. Relative to direct-on-line starting, starting torque is multiplied by approximately:
A cage motor has rotor resistance R2 = 0.40 ohm and rotor leakage reactance X2 = 2.0 ohm per phase (at standstill). The slip at maximum torque is approximately:
A DC shunt motor runs at constant armature voltage. Weakening the field flux (reducing If) has which immediate effect on no-load speed?
A DC motor is supplied at 220 V and draws 50 A. Copper, iron and mechanical losses total 900 W. What is the efficiency?
A 400 V cage motor has rated current In = 42 A and a nameplate ratio Id/In = 7.0. What line current is drawn at the instant of direct-on-line starting?
Loading more…