What does GSIUR 1998 stand for and what does it govern?

Tap to reveal definition
Card 1 of 50Gas Legislation & GSIUR

Filter by Topic

Jump to Card

About These ACS CCN1 Flashcards

These 50 flashcards are designed to help you memorize key terms and definitions for the ACS CCN1 Core Domestic Natural Gas Safety Assessment. Each card shows a term on the front and its definition on the back—the classic flashcard format for vocabulary memorization. Use these alongside our practice questions to build both recall and comprehension.

Topics Covered

Gas Legislation & GSIUR7 cards
Tightness Testing & Let-By8 cards
Gas Rating & Gas Properties6 cards
Pipework & Installation5 cards
Ventilation5 cards
Flueing & Spillage Testing6 cards
Combustion & CO/CO2 Analysis6 cards
Unsafe Situations & Emergencies7 cards

Complete Flashcard Reference

Review every term in this set. Open any term to reveal its definition.

What does GSIUR 1998 stand for and what does it govern?

The Gas Safety (Installation and Use) Regulations 1998 - the principal law covering the safe installation, maintenance and use of gas fittings and appliances in Great Britain. It requires anyone doing gas work for hire or reward to be competent and Gas Safe registered.

Which body must a gas operative working for hire or reward be registered with, and what did it replace?

The Gas Safe Register - the legal registration body since 1 April 2009, when it replaced CORGI. Registration is required under GSIUR for anyone carrying out gas work for reward.

How often must a landlord arrange a gas safety check on relevant appliances and flues, and what record is issued?

Every 12 months (GSIUR Regulation 36). The engineer issues a Landlord Gas Safety Record (LGSR, often called a CP12); a copy must be given to the tenant, normally within 28 days of the check.

Which body enforces gas safety law, and which body holds the operative register?

The Health and Safety Executive (HSE) enforces GSIUR 1998. The Gas Safe Register holds the register of competent businesses and operatives - enforcement and registration are separate roles.

What must an operative hold to prove competence for domestic natural gas work under GSIUR?

Current, relevant ACS certificates under the Nationally Accredited Certification Scheme - CCN1 core plus the appropriate appliance modules (e.g. CENWAT, CKR1, HTR1). Competence is normally re-assessed every 5 years.

On discovering a dangerous gas appliance you were not called to work on, what must you do?

You cannot ignore it. Follow the GIUSP: make it safe where possible (with the gas user's permission), warn the responsible person in writing, and label the appliance. Discovering it during other work still triggers the duty to act.

Under GSIUR, may an operative leave an appliance they know to be immediately dangerous connected and in use?

No. It is an offence to leave a gas appliance or installation connected and in use when it is known to be dangerous. It must be made safe or disconnected following GIUSP, after seeking the gas user's permission.

What is the nominal working (operating) pressure of natural gas at a domestic meter outlet?

20-21 mbar. The meter regulator holds the supply at this pressure; a reading well below this can indicate an undersized supply, a partially closed valve, or a regulator fault.

What is the purpose of the let-by test, and at what pressure is it carried out?

To confirm the emergency control valve (ECV) is holding and not letting gas pass. With the ECV closed, apply 7-10 mbar and observe for 1 minute - any rise in pressure means gas is passing the closed valve.

During a let-by test, what result means the ECV has failed?

Any rise in gauge pressure over the 1-minute test period. A rising gauge shows gas is passing the closed ECV, so a valid tightness test cannot proceed until the valve is rectified or isolated.

At what pressure is the domestic natural gas tightness test carried out, and how long is stabilisation?

At the working pressure of 20-21 mbar, after a 1-minute stabilisation period. Stabilisation lets the gas temperature settle so the timed reading is not affected by temperature change.

How long is the timed tightness-test period on a domestic installation, after stabilisation?

2 minutes. The permissible pressure drop over this period depends on the meter, the pipework size, and whether appliances are connected.

On an existing U6/G4 installation with appliances and pipework up to 28mm, what is the maximum permissible pressure drop over the 2-minute test?

4 mbar (traditional meter-size method). For pipework over 28mm the allowance reduces to 2.5 mbar. IGEM/UP/1B Edition 4, mandatory from 1 October 2026, instead bases the permissible drop on calculated installation volume.

For an existing U6/G4 installation with pipework over 28mm and appliances fitted, what is the maximum permissible tightness-test drop?

2.5 mbar over the 2-minute test (traditional method), versus 4 mbar for pipework up to 28mm. The larger internal volume of bigger pipework means a smaller allowable drop.

What pressure drop is permitted on a tightness test of new pipework with no appliances connected?

No drop at all - zero. A new installation must be completely sound before appliances and any let-by allowances are considered; any measurable drop means a leak that must be found and fixed.

What approximate gross calorific value is used for UK natural gas in the heat-input calculation?

About 38.76 MJ/m3 (roughly 10.76 kWh/m3) is the standard gas-rating figure. Actual National Grid supply CV varies (about 37.5-43 MJ/m3, typically near 39.5), but 10.76 kWh/m3 is the value used to convert a measured gas rate to kW.

How do you convert a measured gas rate (m3/h) to gross heat input in kW?

kW = gas rate (m3/h) x gross CV (MJ/m3) / 3.6. Using a CV of about 38.76 MJ/m3 this simplifies to kW = gas rate x 10.76. Divide by 3.6 because 1 kWh = 3.6 MJ.

How is an appliance gas-rated using a metric (m3) meter?

With only that appliance running, time one revolution or a known volume of the test dial: gas rate (m3/h) = volume x 3600 / time in seconds. Multiply by the CV to get heat input in kW, then compare with the data plate to check the appliance is burning correctly.

What is the approximate relative density of natural gas, and why does it matter?

About 0.6 (air = 1.0), so natural gas is lighter than air and rises. This affects where a leak accumulates and where detectors are sited - the opposite of LPG, which is heavier than air and sinks to low level.

What are the flammability (explosive) limits of natural gas in air?

Roughly LEL 5% to UEL 15% by volume. Below 5% the mixture is too lean to ignite and above 15% it is too rich; between these limits a source of ignition can cause an explosion.

What is the difference between standing pressure and working pressure?

Standing pressure is measured with the appliance(s) turned off, so there is no gas flow; working pressure is measured with the appliance running. An excessive drop between the two can indicate an undersized supply or a regulator problem.

What is the maximum permitted pressure drop between the meter outlet and any appliance on a domestic installation?

1 mbar. Pipework must be sized so that at full flow the pressure loss from meter to the furthest appliance does not exceed 1 mbar, ensuring appliances receive correct working pressure.

Where must main equipotential bonding be connected to the gas installation pipework?

Within 600mm of the meter outlet, on the consumer's side of the meter and before any branch or tee. It clamps the gas pipe to earth to prevent dangerous potential differences.

Is fitting main protective bonding to gas pipework the gas operative's job or the electrician's?

Bonding is electrical work carried out to BS 7671, so it is the electrician's remit. However, the gas operative must check that bonding is present and correctly positioned within 600mm of the meter, and advise or report if it is missing or inadequate.

How must gas pipe passing through a wall be protected?

It must run in a continuous sleeve through the wall, with the sleeve sealed at one end so any gas leaking within the wall is vented to a safe place, and the pipe protected from contact damage and corrosion.

What is purging, and why is it done after pipework or meter work?

Purging displaces the air (or gas) in the pipework with the fuel gas so that no potentially explosive air/gas mixture remains inside the system. It ensures appliances light on gas rather than air and removes any residual air after installation.

Why do open-flued gas appliances need purpose-provided air vents?

To supply combustion air and prevent products of combustion, including carbon monoxide, from building up in the room. Insufficient air causes incomplete combustion and spillage, creating a CO hazard.

How is the ventilation free area for an open-flued appliance calculated under BS 5440-2?

5 cm2 of free area for every kW of net input above the first 7 kW. Example: a 20 kW net open-flued appliance needs (20 - 7) x 5 = 65 cm2 of purpose-provided ventilation.

Do room-sealed (Type C) appliances need purpose-provided room ventilation for combustion?

No. A room-sealed appliance draws its combustion air directly from outside and discharges outside through a sealed system, so it needs no combustion-air vent to the room - a key safety advantage over open-flued types.

Is the BS 5440-2 ventilation calculation based on gross or net heat input?

Net (rated) input. BS 5440-2 covers gas appliances up to 70 kW net, and the (input - 7 kW) x 5 cm2 open-flue rule is applied using the net input figure.

Why does an appliance installed in a compartment or cupboard need both high- and low-level vents?

Low-level vents supply combustion and cooling air, while high-level vents remove the heat that builds up in the enclosed space, preventing the appliance from overheating. These are additional to any room combustion-air requirement.

What is the difference between an open-flued (Type B) and a room-sealed (Type C) appliance?

An open-flued appliance takes combustion air from the room and discharges products up a flue; a room-sealed appliance takes air from, and discharges products to, outside through a sealed system, isolating combustion from the room air.

What is a flueless (Type A) appliance, and what limits its use?

An appliance with no flue that discharges products of combustion straight into the room, such as a cooker. Because of this it needs adequate room volume and ventilation and is limited in heat input relative to the room size.

What does a flue flow test check on an open-flued appliance?

That the flue is clear and drawing correctly. Smoke (from a smoke pellet or match) held at the draught diverter should be pulled up the flue with no significant spillage into the room, confirming an adequate updraught before appliance operation.

What does a spillage test verify, and roughly when is the reading taken?

That combustion products are carried safely up the flue rather than spilling into the room. With the appliance running at full rate, spillage is checked (typically after about 5 minutes) using smoke held at the edge of the draught diverter.

Why must a spillage test be repeated with extract fans running and doors and windows closed?

To test the worst case. An extractor fan can depressurise the room and pull products of combustion back down an open flue (spillage). The test must still pass with fans running and doors and windows in their least favourable position.

Which standard governs flue terminal positions, and why do minimum clearances matter?

BS 5440-1. Terminals must be sited with minimum clearances from windows, doors, corners and other openings so that combustion products disperse safely and cannot re-enter the building.

What are the products of complete combustion of natural gas?

Carbon dioxide (CO2) and water vapour (H2O), plus heat. Complete combustion requires sufficient air/oxygen; a crisp blue flame is usually a sign of it.

What dangerous gas is produced by incomplete combustion, and what commonly causes it?

Carbon monoxide (CO). Causes include insufficient air or ventilation, a blocked or restricted flue, and a dirty or misaligned burner. CO is toxic, colourless and odourless, which is why it is so dangerous.

What CO/CO2 ratio indicates acceptable combustion on a domestic appliance, per BS 7967?

0.004 (0.0040) or below is the accepted limit for a correctly operating appliance. A ratio above 0.004 indicates incomplete combustion, so the appliance must be investigated, serviced, or taken out of use.

Which standard covers the use of electronic combustion (flue gas) analysers, and what do they measure?

BS 7967. The analyser measures CO and CO2 (and derives the CO/CO2 ratio, along with oxygen and flue temperature) to confirm whether an appliance is burning safely and efficiently.

What does a correctly adjusted natural gas flame look like, and what does yellow or sooty tipping suggest?

A crisp blue flame indicates good, complete combustion. Lazy yellow flames, sooting or yellow tipping suggest incomplete combustion and possible carbon monoxide production, so the appliance needs investigating.

To which standard should a domestic carbon monoxide alarm conform, and is it a substitute for correct installation?

BS EN 50291. A CO alarm is an audible warning device only - a backup, not a replacement for correct installation, ventilation, flueing, servicing and combustion checks.

Which procedure and standard classifies gas defects as unsafe situations?

The Gas Industry Unsafe Situations Procedure (GIUSP), published as IGEM/G/11. It defines the classifications - Immediately Dangerous, At Risk and Not to Current Standards - and the actions an operative must take.

What does 'Immediately Dangerous' (ID) mean under GIUSP?

An installation or appliance that, if used or left connected, is an immediate danger to life or property. It must be made safe (with permission) or disconnected, labelled 'Danger - Do Not Use', and reported - never left in use.

What does 'At Risk' (AR) mean under GIUSP?

A situation where one or more recognised faults exist that could become dangerous. With the user's permission the appliance should be turned off and labelled; the user is advised not to use it until it has been rectified.

What does 'Not to Current Standards' (NCS) mean under GIUSP?

The installation does not meet current standards but is not immediately dangerous or at risk, so it is safe to continue using. The gas user should be advised in writing so it can be upgraded over time.

What notice is attached to an ID or AR appliance, and what consent is needed to disconnect it?

A 'Danger - Do Not Use' warning notice/label. The operative must seek the gas user's permission before turning off or disconnecting; if permission is refused, the situation is still recorded and reported as appropriate.

What is the UK National Gas Emergency Service number for reporting a gas escape?

0800 111 999 - the free, 24-hour national gas emergency line for reporting suspected gas escapes or emergencies in Great Britain.

When must a dangerous gas fitting be reported under RIDDOR, and to whom?

A registered gas engineer must report to the Health and Safety Executive (HSE) any gas fitting they consider so dangerous - by design, construction, installation, modification or servicing - that someone could die, be hospitalised, or be rendered unconscious. In practice this covers Immediately Dangerous situations.

Frequently Asked Questions

What is the ACS CCN1 assessment and why do I need it?

CCN1 (Core Domestic Natural Gas Safety) is the core competence assessment required to register with the Gas Safe Register for domestic natural gas work in Great Britain. You must hold it, alongside the relevant appliance modules (such as CENWAT, CKR1 or HTR1), to work legally on domestic gas. It is open book and combines written theory with an observed practical, and every subject area must be passed.

What tightness-test pressures and drops should I know for CCN1?

The let-by test on the emergency control valve uses 7-10 mbar for 1 minute with no rise permitted. The tightness test is carried out at the working pressure of 20-21 mbar for 2 minutes after a 1-minute stabilisation. On an existing U6/G4 installation with appliances, the traditional permissible drop is 4 mbar for pipework up to 28mm and 2.5 mbar over 28mm; new pipework with no appliances permits no drop. Note that IGEM/UP/1B Edition 4 (mandatory from 1 October 2026) replaces the meter-size method with permissible drops based on calculated installation volume.

How do you gas rate an appliance and calculate heat input?

Time a known volume on the metric meter with only that appliance running: gas rate (m3/h) = volume x 3600 / time in seconds. Heat input in kW = gas rate x gross calorific value (MJ/m3) / 3.6. Using the standard gas-rating CV of about 38.76 MJ/m3 (roughly 10.76 kWh/m3), this simplifies to kW = m3/h x 10.76. Compare the result with the appliance data plate.

What CO/CO2 ratio counts as a pass in combustion analysis?

Under BS 7967, a CO/CO2 ratio of 0.004 (0.0040) or below is the accepted limit for a correctly operating domestic appliance. A ratio above 0.004 indicates incomplete combustion and a potential carbon monoxide hazard, so the appliance must be investigated, serviced, or taken out of use.

What do the GIUSP classifications ID, AR and NCS mean?

Under the Gas Industry Unsafe Situations Procedure (IGEM/G/11): Immediately Dangerous (ID) is an immediate danger to life or property and must never be left in use; At Risk (AR) has one or more faults that could become dangerous; and Not to Current Standards (NCS) is safe to use but does not meet current standards. ID and AR appliances receive a 'Danger - Do Not Use' warning notice, and the operative must seek the gas user's permission before disconnecting.

What is the retake policy if I fail a CCN1 subject area?

There is no nationally-mandated waiting period between ACS re-sits (unlike some other exams). If you do not pass a subject area, you rebook and re-sit that component at your ACS-approved centre subject to slot availability and a re-sit fee. Policies and fees vary by centre, so confirm the details with the centre where you booked.

How often must CCN1 be renewed?