Under IPC Chapter 1, who has the primary authority to approve alternative materials, designs, or methods of construction shown on plumbing plans?
General Regulations
Question · Easy
When reviewing submitted plumbing construction documents, which item is the plans examiner NOT required to verify under IPC 107?
Question · Medium
Chapter 1: Exam Overview, Administration & Plan Review Workflow
1.1 ICC P3 Exam Overview: Format, References & Content Weights
Study guide
According to IPC 305.4, what is the minimum depth of cover required for water service pipe installed below grade?
Trades Exam Prep Podcast
Listen on Spotify
Podcast
IPC 305.6 requires that piping passing under or through a concrete or masonry wall be protected. Which detail on a plumbing plan would satisfy this requirement?
Under IPC 312, which test pressure is required for a DWV system when tested with air?
Question · Hard
A restaurant plan shows a dining area with a total occupant load of 150 (75 male / 75 female). Using IPC Table 403.1, what is the minimum number of water closets required for each sex?
Plumbing Fixtures
1.2 Scope, Intent, and Administrative Authority
Per IPC 403.1.1, in which occupancies is the single-user (family/assisted-use) toilet room permitted to be counted toward BOTH the male and female required fixture count?
Under IPC 403.1.2, when may up to 67% of the required male water closets be substituted with urinals?
According to IPC 405.3.1, what is the minimum required clearance from the centerline of a water closet to any side wall or partition?
IPC 405.3.1 requires what minimum clearance in front of a water closet?
1.3 Construction Documents & Submittal Requirements
Per IPC 604.4, the maximum flow rate for a public lavatory faucet is:
Under IPC 604.4, the maximum flow rate for a water closet is:
IPC 410.1 requires drinking fountains in occupancies with what minimum occupant load (absent bottle-filler substitutions)?
Per IPC 411, which fixture is typically required to have an emergency eyewash within 10 seconds' travel in a laboratory plan?
1.4 Inspections, Testing Protocols & Department Operations
IPC 412.1 requires a service sink (mop basin) in which of the following buildings?
When reviewing a commercial plan, what is the code minimum number of service sinks required per floor under IPC 412.4?
Per IPC Table 403.1, a business occupancy (B) requires one water closet per how many occupants of each sex up to the first 50 occupants?
A business occupancy plan shows 120 occupants split 60/60 by sex. How many water closets are required for each sex per IPC Table 403.1?
Chapter 2: General Regulations, Materials & Pipe Protection
2.1 Piping Protection, Trenching & Bedding
Per IPC 405.3.2, the minimum depth of a bathtub water seal shall be:
Per IPC 419, a urinal must be supplied water at a maximum flush volume of:
IPC 424.3 requires individual shower control valves to be of what type to prevent scalding?
IPC 407.2 requires bathtubs to have a minimum waste outlet size of:
2.2 Approved Piping Materials, Joints & Connections
IPC 416.3 requires a lavatory waste outlet to be at least what diameter?
IPC Table 702.1 lists acceptable drain, waste and vent pipe materials above ground. Which is NOT an IPC-approved above-ground DWV material?
IPC 501.2 requires water heater access. What minimum clear working space is required in front of a water heater for inspection and servicing?
Water Heaters
Per IPC 504.5, the temperature and pressure (T&P) relief valve discharge pipe shall:
2.3 Piping Hangers, Supports & Thermal Expansion
IPC 504.7 requires a water heater drain pan under a storage water heater when leakage would cause damage. What is the minimum pan depth and drain size?
Per IPC 607.1.2, hot water distribution piping shall be designed so that the maximum developed length from the source of hot water to the farthest fixture does not exceed the limits of which code?
IPC 501.8 requires what minimum seismic restraint for water heaters in Seismic Design Category D?
Per IPC 504.4, what device must be installed on the cold water supply to every storage water heater?
Chapter 3: Plumbing Fixtures, Occupant Load & Minimum Fixture Counts
3.1 Occupant Load Calculation & IPC Table 403.1
When reviewing gas water heater plans, which combustion air requirement is found in IPC 501.5?
Per IPC 504.1, where a storage tank water heater is installed on an upper floor that could cause damage on leakage, what provision is required?
Per IPC Table 604.3, the minimum static water pressure at a fixture must be at least:
Water Supply
IPC 604.8 requires what device when the static water supply pressure exceeds 80 psi?
3.2 Separate Facilities, Urinal Substitution & Exceptions
Per IPC E103.3 (Appendix E), when sizing water distribution by fixture units, a private bathroom group (water closet, lavatory, bathtub/shower) is assigned:
IPC 604.2 requires water distribution system design to be capable of providing adequate flow and pressure at fixtures based on which factor?
Per IPC 603.1, which water service pipe material is NOT permitted underground outside a building?
IPC 608 requires protection of potable water supplies from cross-connection. Which backflow preventer is rated for use under continuous pressure AND health hazards?