Orientation, ICS + Hazmat
Not publishedof exam
Fire Behavior
Not publishedof exam
PPE + SCBA
Not publishedof exam
Fireground Skills
Not publishedof exam
Search, Rescue + Survival
Not publishedof exam
Quick Facts
- Standard
- NFPA 1010 Chapter 6
- Edition
- 2024 edition
- Replaced
- NFPA 1001 Chapter 4
- Accreditation
- Pro Board or IFSAC
- Who certifies
- State or regional entity
- Questions
- Set by certifying entity
- Pass mark
- Entity set; 70% common
- Also required
- Practical skills evaluation
- Hazmat
- Operations plus product control
- Pro Board deadline
- June 30, 2026
Pro Board vs IFSAC
Pro Board
- Accredits certifying entities
- Over 75 agencies
- Seal aids reciprocity
IFSAC
- Certificate Assembly accredits entities
- Degree Assembly accredits programs
- Also accredits internationally
Both accredit, neither tests
Standards Map 2026
- NFPA 1010
- Firefighter pro qualifications2024
- Chapter 5
- New Support Person level
- Chapter 6
- Firefighter I JPRs
- Chapter 7
- Firefighter II JPRs
- Replaced 1001
- Also 1002, 1003, 1005
- NFPA 470
- Hazmat responder competencies
- NFPA 1970
- Turnouts, SCBA, PASS design
- NFPA 1850
- Gear care and retirement
- NFPA 1930
- Hose and ladder testing
- NFPA 1550
- Responder health and safety
- NFPA 1580
- Medical, fitness, rehab
NFPA 704 vs DOT Placard
NFPA 704
- Fixed facilities
- Four colored quadrants
- Ratings 0 to 4
DOT placard
- Transport vehicles
- Hazard class number
- UN identification number
Building versus vehicle
ICS Basics
- Span of control
- Three to seven5 ideal
- Unity of command
- One supervisor each
- Unified command
- Agencies share one plan
- Type 5 incident
- Smallest; one operational period
- Type 1 incident
- Largest, most complex
- IAP
- Incident action plan
- PAR
- Personnel accountability report
- Clear text
- Plain language, no codes
- Accountability tag
- Tracks who is inside
Hazmat + NFPA 704
- Blue quadrant
- Health hazardLeft
- Red quadrant
- FlammabilityTop
- Yellow quadrant
- Instability or reactivityRight
- White quadrant
- Special: OX, W-slashBottom
- Rating scale
- 0 minimal to 4
- NFPA 704 use
- Fixed facilities only
- DOT placard
- Materials in transport
- ERG orange
- Guide pages
- ERG green
- Isolation distances
- Firefighter I hazmat
- Operations with product control
Fire Tetrahedron
Fuel, Heat, Oxygen, Chain reaction
Flashover vs Backdraft
Flashover
- Heat driven
- Rollover and darkening
- All contents ignite
Backdraft
- Oxygen driven
- Puffing smoke, stained glass
- Explodes on air entry
Heat versus oxygen
Fire Development
- Fire triangle
- Fuel, heat, oxygen
- Fire tetrahedron
- Adds chemical chain reaction
- Incipient
- Ignition, room unaffected
- Growth
- Plume builds hot layer
- Fully developed
- All fuels burning
- Decay
- Fuel or oxygen exhausted
- Ventilation-limited
- Oxygen starved, fuel remains
- Flashover
- Transition, not a stage
Heat Transfer
- Conduction
- Through solid contact
- Convection
- Moving hot gases
- Radiation
- Across open space
- Direct flame contact
- Flame touches new fuel
- Exposure fires
- Radiation drives spread
- Thermal layering
- Hot gases stay high
Hostile Fire Events
- Flashover
- Heat driven, simultaneous ignition
- Flashover temperature
- About 1,100 F
- Flashover warning
- Rollover, driving heat, darkening
- Rollover
- Flame across ceiling gases
- Backdraft
- Oxygen driven, smoke explodes
- Backdraft warning
- Puffing smoke, stained windows
- Backdraft relief
- Vertical vent above fire
- Smoke explosion
- Ignites outside fire room
- Gas cooling
- Short bursts into layer
NFPA 1970 vs NFPA 1850
NFPA 1970
- Product design standard
- Turnouts, SCBA, PASS
- Aimed at manufacturers
NFPA 1850
- Care and maintenance
- Advanced inspection yearly
- Ten-year retirement
Built versus maintained
Turnout Ensemble
- Outer shell
- Flame and abrasion resistance
- Moisture barrier
- Blocks water, steam, chemicals
- Thermal liner
- Most of the insulation
- Particulate hood
- Blocks fireground carcinogens
- Compression burn
- Squeezed layers lose insulation
- Helmet
- Impact and heat protection
- Boots and gloves
- Puncture and cut protection
- Advanced inspection
- At least every year
- Retirement
- Ten years from manufacture
- Rehab
- Rest, fluids, medical monitoring
SCBA Facts
- Open-circuit SCBA
- Exhaled air vents out
- Positive pressure
- Facepiece stays pressurized
- EOSTI
- Low-air alarm activates
- 33% setting
- NFPA 1981 alarm point
- NFPA 1970 EOSTI
- Graduated by cylinder rating
- Rule of air management
- Exit before alarm sounds
- PASS pre-alert
- About 20 seconds motionless
- PASS full alarm
- About 30 seconds motionless
- Facial hair
- Breaks the facepiece seal
- Seal check
- Every donning, every shift
- UAC
- Universal air connection
Extinguisher PASS
Pull, Aim, Squeeze, Sweep
Solid Bore vs Fog
Solid bore
- 50 psi handline
- Greater reach and penetration
- Less steam produced
Combination fog
- 100 psi standard
- Adjustable stream pattern
- Better gas cooling
Reach versus flexibility
Ventilation Picker
- No charged line ready→Do not vent(Wait for attack)
- Contents fire, sound windows→Horizontal vent(Doors and windows)
- Attic or cockloft fire→Vertical vent(Directly over fire)
- Backdraft signs present→Vertical vent(Relieve from above)
- Roof spongy or unsafe→Horizontal only(No roof crews)
- Large open floor plan→PPV(Exhaust opening first)
- Light smoke after knockdown→Hydraulic ventilation(Fog out window)
- Smoke filling stairwell→Vent stairwell top(Protects egress)
Hose + Handlines
- 1.75-inch line
- Residential attack, 150-180 gpm
- 2.5-inch line
- Commercial, about 250 gpm
- 1.5-inch line
- Older, lighter attack line
- 3-inch and larger
- Supply line duty
- Booster line
- Small outside fires only
- Attack hose test
- Minimum 300 psi annually
- Supply hose test
- Minimum 200 psi annually
- Friction loss
- Rises with flow squared
- Storz coupling
- Sexless quarter-turn connection
- Higbee indicator
- Aligns coupling threads
Conventional Forcing
Gap, Set, Force
Horizontal vs Vertical Vent
Horizontal
- Doors and windows
- Faster and safer
- Typical contents fires
Vertical
- Cut roof opening
- Directly over fire
- Attic and cockloft
Existing versus new opening
Attack Line Picker
- Single-family residence→1.75-inch line(150-180 gpm)
- Commercial or heavy fire→2.5-inch line(About 250 gpm)
- Long interior stretch→2.5-inch line(Less friction loss)
- Standpipe operation→2.5-inch line(Smooth bore preferred)
- Defensive exterior attack→Master stream(80 psi solid bore)
- Protecting an exposure→Second line(Blocks radiant heat)
- Vehicle fire→1.75-inch line(Approach at angle)
- Small trash fire→Booster line(Exterior Class A)
Nozzles + Fire Streams
- Solid bore handline
- 50 psi nozzle pressure
- Solid bore master
- 80 psi nozzle pressure
- Combination fog
- 100 psi standard
- Low-pressure fog
- 75 or 50 psi
- Straight stream
- Fog nozzle, narrowed pattern
- Direct attack
- Water onto burning fuel
- Indirect attack
- Steam conversion, unoccupied space
- Combination attack
- O, Z or T
- Nozzle pressure
- Fixed design value
Hydrant Colors
Blue, Green, Orange, Red descending
Salvage vs Overhaul
Salvage
- Protects property
- Covers and chutes
- Starts during fire
Overhaul
- Exposes hidden fire
- Opens walls and ceilings
- After knockdown
Protect versus expose
Ladder Picker
- Second-floor window→24-foot extension(Butt about 6 feet)
- Third floor or roof→35-foot extension
- Working on pitched roof→Roof ladder(Hooks over ridge)
- Climbing to flat roof→Extension ladder(Tip 3-5 rungs above)
- Rescue from window→Extension ladder(Tip below the sill)
- Venting a window→Extension ladder(Tip at window top)
- Attic or scuttle hatch→Folding ladder(Narrow spaces)
Water Supply + Hydrants
- Class AA
- Light blue, 1,500+ gpm
- Class A
- Green, 1,000-1,499 gpm
- Class B
- Orange, 500-999 gpm
- Class C
- Red, under 500 gpm
- Hydrant barrel
- Chrome yellow
- Rating pressure
- 20 psi residual
- Static source
- Pond, river, cistern
- Drafting
- Hard suction from static
- Forward lay
- Hydrant toward the fire
- Reverse lay
- Fire back to hydrant
- Color scheme status
- Recommended, not mandatory
Forcible Entry Picker
- Door may be unlocked→Try before you pry
- Inward-swinging wood door→Fork end(Gap, set, force)
- Outward-swinging metal door→Adz end(Gap above lock)
- Storefront with cylinder→K-tool(Through-the-lock)
- Heavy commercial door→Hydraulic spreader(Rabbit tool)
- Padlock on hasp→Bolt cutters(Or duckbill lock breaker)
- Speed over damage→Rotary saw(Most destructive)
Ground Ladders
- Climbing angle
- About 75 degrees
- Butt spacing
- One quarter working length
- Working length
- Butt to top support
- Roof access tip
- Three to five rungs above
- Window rescue tip
- Even with or below sill
- Ventilation window tip
- Even with window top
- Fly section
- Faces away from building
- Leg lock
- Secures you for work
- Roof ladder
- Hooks over the ridge
- 24-foot extension
- Typical second-floor window
- 35-foot extension
- Third floor or roof
- Folding ladder
- Attic and scuttle access
Extinguisher Picker
- Wood, paper, cloth→Water or ABC(Class A)
- Gasoline or solvent→Dry chemical or foam(Class B)
- Energized electrical panel→Carbon dioxide(Class C)
- Magnesium or sodium→Dry powder agent(Never water)
- Kitchen fryer fire→Wet chemical(Class K)
- Mixed occupancy risk→ABC dry chemical(Broadest coverage)
Forcible Entry
- The irons
- Halligan plus flathead axe
- Fork end
- Inward-swinging doors
- Adz end
- Outward-swinging doors
- Pick end
- Punches locks and glass
- Try before you pry
- Check unlocked doors first
- Gap, set, force
- Conventional prying sequence
- K-tool
- Through-the-lock cylinder pull
- Rabbit tool
- Hydraulic door spreader
- Bam-bam tool
- Screws into lock cylinder
- Through-the-lock
- Least damage method
Ventilation
- Tactical ventilation
- Planned heat, smoke removal
- Horizontal
- Existing doors and windows
- Vertical
- Roof opening over fire
- PPV
- Blower pressurizes the building
- Negative pressure
- Fan pulls smoke out
- Hydraulic
- Fog stream out window
- Flow path
- Inlet to outlet travel
- Exhaust opening
- Make it before pressurizing
- Coordination rule
- Charged line in place
- Sounding the roof
- Tests roof before walking
Portable Extinguishers
- Class A
- Wood, paper, cloth
- Class B
- Flammable liquids and gases
- Class C
- Energized electrical equipment
- Class D
- Combustible metals
- Class K
- Cooking oils and fats
- Dry chemical
- Common ABC agent
- Carbon dioxide
- Class BC, no residue
- Water can
- Class A only
Knots + Ropes
- Life safety rope
- Supports people; block creel
- Utility rope
- Tools and cordons only
- Clove hitch
- Attaches rope to object
- Bowline
- Fixed loop that holds
- Figure eight on bight
- Loop anywhere in rope
- Becket bend
- Joins unequal diameter ropes
- Half hitch
- Backs up other knots
- Water knot
- Joins webbing ends
- Working end
- Part being tied
Salvage + Overhaul
- Salvage
- Protects property from damage
- Overhaul
- Finds hidden fire extension
- Salvage cover
- Diverts and catches water
- Water chute
- Routes water outside
- Overhaul SCBA
- Keep it on; carcinogens
- Preserve evidence
- Do not disturb origin
- Thermal imager
- Finds hidden hot spots
VEIS Search
Vent, Enter, Isolate, Search
Primary vs Secondary Search
Primary
- During suppression
- Fast systematic sweep
- Life safety first
Secondary
- After fire control
- Slow and thorough
- Different crew preferred
Speed versus certainty
Search + Rescue
- Primary search
- Fast sweep during suppression
- Secondary search
- Thorough recheck after control
- Oriented search
- Officer anchors at door
- Team search
- Crew stays together
- VEIS
- Targeted single-room search
- Sweep high too
- Beds, cribs, tubs, closets
- Behind doors
- Common victim location
- Stay low
- Keep wall or hoseline
- Blanket drag
- Low-profile victim removal
- Two-person seat carry
- Conscious, non-ambulatory victim
- Extremity carry
- One arms, one legs
Mayday LUNAR
Location, Unit, Name, Assignment, Resources
Type IV vs Type V
Type IV
- Heavy timber members
- No concealed spaces
- Massive fuel load
Type V
- Wood frame
- Lightweight trusses, I-joists
- Can fail in minutes
Mass versus lightweight
Survival + RIT
- Two-in, two-out
- OSHA 1910.134(g)(4)
- Rescue exception
- Known savable victim inside
- Incipient exception
- Rule starts beyond incipient
- One outside member
- May also be IC
- RIT or RIC
- Dedicated firefighter rescue crew
- RIT kit
- Spare air with UAC
- Mayday
- Call it early
- LUNAR
- Mayday report format
- PASS activation
- After the Mayday transmission
Building Construction
- Type I
- Fire-resistive; protected steel, concrete
- Type II
- Noncombustible, unprotected steel
- Type III
- Ordinary: masonry walls, wood joists
- Type IV
- Heavy timber, large members
- Type V
- Wood frame; structure is fuel
- Type I hazard
- Spalling concrete, long burns
- Type II hazard
- Steel elongates, roof sags
- Type III hazard
- Concealed void space spread
- Type V hazard
- Lightweight trusses fail fast
Common Traps
Flashover vs backdraft
Flashover is heat driven ≠ Backdraft is oxygen driven
Rollover vs flashover
Rollover: ceiling gases ignite ≠ Flashover: whole room ignites
Standard vs certificate
NFPA writes the standard ≠ State entity issues certificate
Chapter 4 vs Chapter 6
NFPA 1001 used Chapter 4 ≠ NFPA 1010 uses Chapter 6
Alarm vs exit trigger
Low-air alarm is late ≠ Air management exits sooner
Class C confusion
Class C means energized ≠ De-energized becomes A or B
Vent timing
Uncoordinated venting grows fire ≠ Coordinated venting supports attack
Build vs maintain standards
NFPA 1970 builds gear ≠ NFPA 1850 maintains gear
Unity vs unified command
Unity: one supervisor each ≠ Unified: agencies share command
Truss vs rafter roof
Lightweight truss fails fast ≠ Conventional rafters last longer
Salvage vs overhaul
Salvage protects property ≠ Overhaul exposes hidden fire
Last Minute
- 1.Firefighter I = NFPA 1010 Chapter 6
- 2.NFPA writes it; state entity certifies
- 3.Flashover heat driven; backdraft oxygen driven
- 4.Radiation crosses the street
- 5.Ladder angle about 75 degrees
- 6.Butt out one quarter working length
- 7.Low-air alarm at 33%
- 8.Green hydrant = 1,000-1,499 gpm
- 9.Solid bore 50 psi; fog 100
- 10.Two-in/two-out before interior attack
- 11.Vertical vent goes over fire
- 12.Type V fails fastest
- 13.Primary is fast; secondary thorough
- 14.LUNAR = Location Unit Name Assignment Resources
- 15.Attack hose tested at 300 psi
- 16.Fork end inward; adz outward
- 17.Span of control 3-7
- 18.Isolate the room during VEIS
Explore More Firefighter Certifications
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
More From This Family
Videos and articles for deeper review.