Cheat sheet

NFPA Firefighter I Cheat Sheet

Quick Facts

Standard
NFPA 1010 Chapter 6
Edition
2024 edition
Replaced
NFPA 1001 Chapter 4
Accreditation
Pro Board or IFSAC
Who certifies
State or regional entity
Questions
Set by certifying entity
Pass mark
Entity set; 70% common
Also required
Practical skills evaluation
Hazmat
Operations plus product control
Pro Board deadline
June 30, 2026

Pro Board vs IFSAC

Pro Board

  • Accredits certifying entities
  • Over 75 agencies
  • Seal aids reciprocity

IFSAC

  • Certificate Assembly accredits entities
  • Degree Assembly accredits programs
  • Also accredits internationally

Both accredit, neither tests

Standards Map 2026

NFPA 1010
Firefighter pro qualifications2024
Chapter 5
New Support Person level
Chapter 6
Firefighter I JPRs
Chapter 7
Firefighter II JPRs
Replaced 1001
Also 1002, 1003, 1005
NFPA 470
Hazmat responder competencies
NFPA 1970
Turnouts, SCBA, PASS design
NFPA 1850
Gear care and retirement
NFPA 1930
Hose and ladder testing
NFPA 1550
Responder health and safety
NFPA 1580
Medical, fitness, rehab

NFPA 704 vs DOT Placard

NFPA 704

  • Fixed facilities
  • Four colored quadrants
  • Ratings 0 to 4

DOT placard

  • Transport vehicles
  • Hazard class number
  • UN identification number

Building versus vehicle

ICS Basics

Span of control
Three to seven5 ideal
Unity of command
One supervisor each
Unified command
Agencies share one plan
Type 5 incident
Smallest; one operational period
Type 1 incident
Largest, most complex
IAP
Incident action plan
PAR
Personnel accountability report
Clear text
Plain language, no codes
Accountability tag
Tracks who is inside

Hazmat + NFPA 704

Blue quadrant
Health hazardLeft
Red quadrant
FlammabilityTop
Yellow quadrant
Instability or reactivityRight
White quadrant
Special: OX, W-slashBottom
Rating scale
0 minimal to 4
NFPA 704 use
Fixed facilities only
DOT placard
Materials in transport
ERG orange
Guide pages
ERG green
Isolation distances
Firefighter I hazmat
Operations with product control

Fire Tetrahedron

Fuel, Heat, Oxygen, Chain reaction

Triangle: first threeFourth: chain reactionBreak any side

Flashover vs Backdraft

Flashover

  • Heat driven
  • Rollover and darkening
  • All contents ignite

Backdraft

  • Oxygen driven
  • Puffing smoke, stained glass
  • Explodes on air entry

Heat versus oxygen

Fire Development

Fire triangle
Fuel, heat, oxygen
Fire tetrahedron
Adds chemical chain reaction
Incipient
Ignition, room unaffected
Growth
Plume builds hot layer
Fully developed
All fuels burning
Decay
Fuel or oxygen exhausted
Ventilation-limited
Oxygen starved, fuel remains
Flashover
Transition, not a stage

Heat Transfer

Conduction
Through solid contact
Convection
Moving hot gases
Radiation
Across open space
Direct flame contact
Flame touches new fuel
Exposure fires
Radiation drives spread
Thermal layering
Hot gases stay high

Hostile Fire Events

Flashover
Heat driven, simultaneous ignition
Flashover temperature
About 1,100 F
Flashover warning
Rollover, driving heat, darkening
Rollover
Flame across ceiling gases
Backdraft
Oxygen driven, smoke explodes
Backdraft warning
Puffing smoke, stained windows
Backdraft relief
Vertical vent above fire
Smoke explosion
Ignites outside fire room
Gas cooling
Short bursts into layer

NFPA 1970 vs NFPA 1850

NFPA 1970

  • Product design standard
  • Turnouts, SCBA, PASS
  • Aimed at manufacturers

NFPA 1850

  • Care and maintenance
  • Advanced inspection yearly
  • Ten-year retirement

Built versus maintained

Turnout Ensemble

Outer shell
Flame and abrasion resistance
Moisture barrier
Blocks water, steam, chemicals
Thermal liner
Most of the insulation
Particulate hood
Blocks fireground carcinogens
Compression burn
Squeezed layers lose insulation
Helmet
Impact and heat protection
Boots and gloves
Puncture and cut protection
Advanced inspection
At least every year
Retirement
Ten years from manufacture
Rehab
Rest, fluids, medical monitoring

SCBA Facts

Open-circuit SCBA
Exhaled air vents out
Positive pressure
Facepiece stays pressurized
EOSTI
Low-air alarm activates
33% setting
NFPA 1981 alarm point
NFPA 1970 EOSTI
Graduated by cylinder rating
Rule of air management
Exit before alarm sounds
PASS pre-alert
About 20 seconds motionless
PASS full alarm
About 30 seconds motionless
Facial hair
Breaks the facepiece seal
Seal check
Every donning, every shift
UAC
Universal air connection

Extinguisher PASS

Pull, Aim, Squeeze, Sweep

Pull the pinAim at baseSqueeze the handleSweep side to side

Solid Bore vs Fog

Solid bore

  • 50 psi handline
  • Greater reach and penetration
  • Less steam produced

Combination fog

  • 100 psi standard
  • Adjustable stream pattern
  • Better gas cooling

Reach versus flexibility

Ventilation Picker

  1. No charged line readyDo not vent(Wait for attack)
  2. Contents fire, sound windowsHorizontal vent(Doors and windows)
  3. Attic or cockloft fireVertical vent(Directly over fire)
  4. Backdraft signs presentVertical vent(Relieve from above)
  5. Roof spongy or unsafeHorizontal only(No roof crews)
  6. Large open floor planPPV(Exhaust opening first)
  7. Light smoke after knockdownHydraulic ventilation(Fog out window)
  8. Smoke filling stairwellVent stairwell top(Protects egress)

Hose + Handlines

1.75-inch line
Residential attack, 150-180 gpm
2.5-inch line
Commercial, about 250 gpm
1.5-inch line
Older, lighter attack line
3-inch and larger
Supply line duty
Booster line
Small outside fires only
Attack hose test
Minimum 300 psi annually
Supply hose test
Minimum 200 psi annually
Friction loss
Rises with flow squared
Storz coupling
Sexless quarter-turn connection
Higbee indicator
Aligns coupling threads

Conventional Forcing

Gap, Set, Force

Gap the doorSet the toolForce the lock

Horizontal vs Vertical Vent

Horizontal

  • Doors and windows
  • Faster and safer
  • Typical contents fires

Vertical

  • Cut roof opening
  • Directly over fire
  • Attic and cockloft

Existing versus new opening

Attack Line Picker

  1. Single-family residence1.75-inch line(150-180 gpm)
  2. Commercial or heavy fire2.5-inch line(About 250 gpm)
  3. Long interior stretch2.5-inch line(Less friction loss)
  4. Standpipe operation2.5-inch line(Smooth bore preferred)
  5. Defensive exterior attackMaster stream(80 psi solid bore)
  6. Protecting an exposureSecond line(Blocks radiant heat)
  7. Vehicle fire1.75-inch line(Approach at angle)
  8. Small trash fireBooster line(Exterior Class A)

Nozzles + Fire Streams

Solid bore handline
50 psi nozzle pressure
Solid bore master
80 psi nozzle pressure
Combination fog
100 psi standard
Low-pressure fog
75 or 50 psi
Straight stream
Fog nozzle, narrowed pattern
Direct attack
Water onto burning fuel
Indirect attack
Steam conversion, unoccupied space
Combination attack
O, Z or T
Nozzle pressure
Fixed design value

Hydrant Colors

Blue, Green, Orange, Red descending

Blue: 1,500+ gpmGreen: 1,000-1,499Orange: 500-999Red: under 500

Salvage vs Overhaul

Salvage

  • Protects property
  • Covers and chutes
  • Starts during fire

Overhaul

  • Exposes hidden fire
  • Opens walls and ceilings
  • After knockdown

Protect versus expose

Ladder Picker

  1. Second-floor window24-foot extension(Butt about 6 feet)
  2. Third floor or roof35-foot extension
  3. Working on pitched roofRoof ladder(Hooks over ridge)
  4. Climbing to flat roofExtension ladder(Tip 3-5 rungs above)
  5. Rescue from windowExtension ladder(Tip below the sill)
  6. Venting a windowExtension ladder(Tip at window top)
  7. Attic or scuttle hatchFolding ladder(Narrow spaces)

Water Supply + Hydrants

Class AA
Light blue, 1,500+ gpm
Class A
Green, 1,000-1,499 gpm
Class B
Orange, 500-999 gpm
Class C
Red, under 500 gpm
Hydrant barrel
Chrome yellow
Rating pressure
20 psi residual
Static source
Pond, river, cistern
Drafting
Hard suction from static
Forward lay
Hydrant toward the fire
Reverse lay
Fire back to hydrant
Color scheme status
Recommended, not mandatory

Forcible Entry Picker

  1. Door may be unlockedTry before you pry
  2. Inward-swinging wood doorFork end(Gap, set, force)
  3. Outward-swinging metal doorAdz end(Gap above lock)
  4. Storefront with cylinderK-tool(Through-the-lock)
  5. Heavy commercial doorHydraulic spreader(Rabbit tool)
  6. Padlock on haspBolt cutters(Or duckbill lock breaker)
  7. Speed over damageRotary saw(Most destructive)

Ground Ladders

Climbing angle
About 75 degrees
Butt spacing
One quarter working length
Working length
Butt to top support
Roof access tip
Three to five rungs above
Window rescue tip
Even with or below sill
Ventilation window tip
Even with window top
Fly section
Faces away from building
Leg lock
Secures you for work
Roof ladder
Hooks over the ridge
24-foot extension
Typical second-floor window
35-foot extension
Third floor or roof
Folding ladder
Attic and scuttle access

Extinguisher Picker

  1. Wood, paper, clothWater or ABC(Class A)
  2. Gasoline or solventDry chemical or foam(Class B)
  3. Energized electrical panelCarbon dioxide(Class C)
  4. Magnesium or sodiumDry powder agent(Never water)
  5. Kitchen fryer fireWet chemical(Class K)
  6. Mixed occupancy riskABC dry chemical(Broadest coverage)

Forcible Entry

The irons
Halligan plus flathead axe
Fork end
Inward-swinging doors
Adz end
Outward-swinging doors
Pick end
Punches locks and glass
Try before you pry
Check unlocked doors first
Gap, set, force
Conventional prying sequence
K-tool
Through-the-lock cylinder pull
Rabbit tool
Hydraulic door spreader
Bam-bam tool
Screws into lock cylinder
Through-the-lock
Least damage method

Ventilation

Tactical ventilation
Planned heat, smoke removal
Horizontal
Existing doors and windows
Vertical
Roof opening over fire
PPV
Blower pressurizes the building
Negative pressure
Fan pulls smoke out
Hydraulic
Fog stream out window
Flow path
Inlet to outlet travel
Exhaust opening
Make it before pressurizing
Coordination rule
Charged line in place
Sounding the roof
Tests roof before walking

Portable Extinguishers

Class A
Wood, paper, cloth
Class B
Flammable liquids and gases
Class C
Energized electrical equipment
Class D
Combustible metals
Class K
Cooking oils and fats
Dry chemical
Common ABC agent
Carbon dioxide
Class BC, no residue
Water can
Class A only

Knots + Ropes

Life safety rope
Supports people; block creel
Utility rope
Tools and cordons only
Clove hitch
Attaches rope to object
Bowline
Fixed loop that holds
Figure eight on bight
Loop anywhere in rope
Becket bend
Joins unequal diameter ropes
Half hitch
Backs up other knots
Water knot
Joins webbing ends
Working end
Part being tied

Salvage + Overhaul

Salvage
Protects property from damage
Overhaul
Finds hidden fire extension
Salvage cover
Diverts and catches water
Water chute
Routes water outside
Overhaul SCBA
Keep it on; carcinogens
Preserve evidence
Do not disturb origin
Thermal imager
Finds hidden hot spots

VEIS Search

Vent, Enter, Isolate, Search

Isolate: close the doorCuts the flow pathOne room at a time

Search + Rescue

Primary search
Fast sweep during suppression
Secondary search
Thorough recheck after control
Oriented search
Officer anchors at door
Team search
Crew stays together
VEIS
Targeted single-room search
Sweep high too
Beds, cribs, tubs, closets
Behind doors
Common victim location
Stay low
Keep wall or hoseline
Blanket drag
Low-profile victim removal
Two-person seat carry
Conscious, non-ambulatory victim
Extremity carry
One arms, one legs

Mayday LUNAR

Location, Unit, Name, Assignment, Resources

Call it earlyThen activate PASSStay on the radio

Type IV vs Type V

Type IV

  • Heavy timber members
  • No concealed spaces
  • Massive fuel load

Type V

  • Wood frame
  • Lightweight trusses, I-joists
  • Can fail in minutes

Mass versus lightweight

Survival + RIT

Two-in, two-out
OSHA 1910.134(g)(4)
Rescue exception
Known savable victim inside
Incipient exception
Rule starts beyond incipient
One outside member
May also be IC
RIT or RIC
Dedicated firefighter rescue crew
RIT kit
Spare air with UAC
Mayday
Call it early
LUNAR
Mayday report format
PASS activation
After the Mayday transmission

Building Construction

Type I
Fire-resistive; protected steel, concrete
Type II
Noncombustible, unprotected steel
Type III
Ordinary: masonry walls, wood joists
Type IV
Heavy timber, large members
Type V
Wood frame; structure is fuel
Type I hazard
Spalling concrete, long burns
Type II hazard
Steel elongates, roof sags
Type III hazard
Concealed void space spread
Type V hazard
Lightweight trusses fail fast

Common Traps

Flashover vs backdraft

Flashover is heat driven Backdraft is oxygen driven

Rollover vs flashover

Rollover: ceiling gases ignite Flashover: whole room ignites

Standard vs certificate

NFPA writes the standard State entity issues certificate

Chapter 4 vs Chapter 6

NFPA 1001 used Chapter 4 NFPA 1010 uses Chapter 6

Alarm vs exit trigger

Low-air alarm is late Air management exits sooner

Class C confusion

Class C means energized De-energized becomes A or B

Vent timing

Uncoordinated venting grows fire Coordinated venting supports attack

Build vs maintain standards

NFPA 1970 builds gear NFPA 1850 maintains gear

Unity vs unified command

Unity: one supervisor each Unified: agencies share command

Truss vs rafter roof

Lightweight truss fails fast Conventional rafters last longer

Salvage vs overhaul

Salvage protects property Overhaul exposes hidden fire

Last Minute

  1. 1.Firefighter I = NFPA 1010 Chapter 6
  2. 2.NFPA writes it; state entity certifies
  3. 3.Flashover heat driven; backdraft oxygen driven
  4. 4.Radiation crosses the street
  5. 5.Ladder angle about 75 degrees
  6. 6.Butt out one quarter working length
  7. 7.Low-air alarm at 33%
  8. 8.Green hydrant = 1,000-1,499 gpm
  9. 9.Solid bore 50 psi; fog 100
  10. 10.Two-in/two-out before interior attack
  11. 11.Vertical vent goes over fire
  12. 12.Type V fails fastest
  13. 13.Primary is fast; secondary thorough
  14. 14.LUNAR = Location Unit Name Assignment Resources
  15. 15.Attack hose tested at 300 psi
  16. 16.Fork end inward; adz outward
  17. 17.Span of control 3-7
  18. 18.Isolate the room during VEIS
Same family resources

Explore More Firefighter Certifications