Cheat sheet

BICSI Technician Cheat Sheet

Field Planning, Implementation and Design

20%of exam

Cable typesBlueprintsSite safetyLabelingCloseout

Establish Pathways and Space

20%of exam

SpacesSupportsConduitBondingFirestopping

Pull Copper and Fiber Cable

12%of exam

Pull setupHorizontal and backbone pullsAir-assisted fiberPull line

Terminate Copper and Fiber Cable

12%of exam

T568A/BInsulation displacementCoaxFiber connectors

Perform Splicing

6%of exam

FusionMechanicalCopper splicesSplice protection

Test Copper and Fiber Cable

7%of exam

Copper certificationTier 1 OLTSTier 2 OTDRTest records

Perform Troubleshooting

7%of exam

TDRVFLOTDR tracesFault isolation

Perform Retrofits

5%of exam

SurveyIdentify active circuitsCutoverAbandoned cable

Apply Integration and Convergence Concepts

7%of exam

Network equipmentWirelessSecurityDASPON

Codes and Standards

4%of exam

Adopted building and fire codesNFPA 70 in U.S. jurisdictionsLocal amendmentsAuthority having jurisdiction

Quick Facts

Exam
BICSI TECH
Written Exam
100 items, mixed formats
Written Time
2 hours
Pass
Both exams
Hands-On First
12 tasks
Task Time
20 min each
Application Fee
$335 member / $400 nonmember
Validity
3 years
Retake
30 days, 90 after third failure

10GBASE-SR Reach by Fiber Type

OM1 33m OM2 82m OM3 300m OM4 400m

OM1 62.5um 33mOM3 laser 300mOM4 400m

Singlemode vs Multimode

Singlemode

  • One spatial mode
  • Common at 1310/1550 nm
  • Long reach with compatible optics

Multimode

  • 50/62.5 µm core
  • Multiple modes
  • Short-reach optics

Match optics, reach and loss budget

Copper Category Picker

  1. Up to 1GbE→Cat 5e(100 MHz)
  2. 5GBASE-T on a rated channel→Cat 6(250 MHz)
  3. 10GBASE-T on existing Cat 6→Cat 6(37–55 m depends on alien crosstalk)
  4. 10GbE 100m→Cat 6A(500 MHz)
  5. 25/40GbE 30m→Cat 8(2000 MHz)
  6. High EMI→Evaluate shielding or fiber(Follow the design)

Copper Categories

Cat 5e
100 MHz, 2.5GBASE-T if qualified100MHz
Cat 6
250 MHz, 5GBASE-T if qualified250MHz
Cat 6A
500 MHz, 10GbE500MHz
Cat 8
2000 MHz, 25/40GBASE-T, 30m channel2GHz
UTP
Unshielded twisted pair
F/UTP
Foil over twisted pairs
S/FTP
Braid + foil pairs
AWG 22-24
Typical conductor gauge

Cat 6 vs Cat 6A

Cat 6

  • 250 MHz
  • 10G reach depends on alien crosstalk
  • UTP common

Cat 6A

  • 500 MHz
  • 10GbE 100m
  • Alien crosstalk

Freq and distance

Fiber Type Picker

  1. Long optical link→Singlemode with rated optics(Check reach and loss budget)
  2. 10GBASE-SR up to 33 m→OM1(62.5um)
  3. 10GBASE-SR up to 82 m→OM2(50um)
  4. 10GBASE-SR up to 300 m→OM3(laser optimized)
  5. 10GBASE-SR up to 400 m→OM4(VCSEL)
  6. 40/100GbE short reach→Match fiber and transceiver(Check the specific optical interface)

Typical Cat 5e/6/6A Horizontal Limits

Channel
100 m max100m
Permanent Link
90 m max90m
Equipment Cord
From patch panel to equipment
Work Area Cord
From outlet to end device
Consolidation Point
Optional connection within the permanent link
Total Cords
10 m total with 90m link

Permanent Link vs Channel

Permanent Link

  • 90 m
  • Excludes cords
  • Tester adapter

Channel

  • 100 m
  • Includes cords
  • Full end-to-end

Tester setup

Fiber Types

OS1
Premises singlemode performance category
OS2
Lower-attenuation singlemode category
OM1
62.5 µm, 10GBASE-SR 33m62.5um
OM2
50 µm, 10GBASE-SR 82m50um
OM3
50 µm, 10GBASE-SR 300m50um
OM4
50 µm, 10GBASE-SR 400m50um
OM5
Wideband MMF for shortwave WDM50um
Core/Clad
MM 50/125, 62.5/125 µm

Safety

PPE
Select protection for the hazard
Lockout/Tagout
Energy isolation
Fiber Shard
Sharps container dispose
Optical Safety
Verify dark fiber before inspection
Ladder
3-point contact
Fall Protection
Match protection to work and location
SDS
Safety data sheet for chemical hazards

Project and Documentation

As-Built
Final installed drawings
Test Reports
Certification records
Warranty
Confirm requirements and term with manufacturer
Blueprint
Read plan/elevation
RFP
Request for proposal
CEC
Continuing ed credits

Firestop Ratings

F fire T temp L leak W water

F hours enduranceL cfm leakageW water resistance

Bonding and Grounding

TBB
Backbone conductor between bonding busbars
Primary Bonding Busbar (PBB)
Central ICT bonding point, formerly TMGB
Secondary Bonding Busbar (SBB)
Local telecom bonding point, formerly TGB
Rack Bonding Busbar (RBB)
Local bonding point on rack
Riser
Common route for a vertical TBB
#6 AWG
Minimum copper TBB size
Long TBB Runs
Size by length per TIA-607

Bonding Chain

Building ground → PBB → TBB → SBB

PBB primaryTBB backboneSBB local busbar

Firestop Systems

F Rating
Time resisting flame passage
T Rating
Time within temperature-rise limit
L Rating
Air leakage at specified test pressure
W Rating
Water resistance under specified test
Through Penetration
Passes fully through rated assembly
Membrane Penetration
One side breach
Firestop Putty
Match approved firestop system
Intumescent
Expands with heat

Pathways and Spaces

Conduit
Calculate fill per raceway rule
Cable Tray
Continuous open cable support
Sleeve
Wall/floor penetration
TR
Telecom room, equipment
Entrance Facility (EF)
Entry and transition for outside cabling
ER
Equipment room, main
Bend Radius
Often 4× diameter. Verify cable specs.

Cable Pulls

Pull setup
Check pathway, bend and pull limits
Pull lubricant
Use a cable-jacket-compatible product
Air-assisted fiber
Feeds fiber into prepared duct
Pull line
Install ahead of the cable

T568A Color Order

WGrn Grn WOrg Blu WBlu Org WBrn Brn

Pin1 WGrnPin3 WOrgPin6 Org

T568A vs T568B

T568A

  • White/green on pin 1
  • Green on pins 1–2
  • Orange on pins 3 and 6

T568B

  • White/orange on pin 1
  • Orange on pins 1–2
  • Green on pins 3 and 6

Orange/green swap

T568A/B Color Order

T568A Pin 1
White/Green
T568A Pin 2
Green
T568A Pin 3
White/Orange
T568A Pin 4
Blue
T568A Pin 5
White/Blue
T568A Pin 6
Orange
T568A Pin 7
White/Brown
T568A Pin 8
Brown
T568B
Swap orange/green pairs

Termination Blocks

110 Block
IDC termination. Check the block’s category.
Krone
LSA-PLUS insulation-displacement system
BIX
Multi-pair IDC cross-connect system
66 Block
Legacy voice IDC block
RJ45
8P8C modular plug
RJ11
Common single-line voice jack wiring (6P2C)
Modular Plug
Terminates patch cord
Jack
Female workstation outlet

Fiber Connectors

LC
Small form factor, snap
SC
Push-pull, 2.5mm
ST
Bayonet, 2.5mm
MTP
US Conec brand of MPO connector
MPO
Push-on multifiber connector
UPC
Ultra physical contact, blue
APC
Angled 8 deg, green
Polish
Higher return loss, less reflection

Fusion vs Mechanical

Fusion

  • Arc joins fiber ends
  • Typically low loss
  • Protect with sleeve

Mechanical

  • Alignment fixture
  • Often uses gel
  • Useful for field repair

Check splice loss against spec

Splice Picker

  1. Min loss→Fusion(Verify low loss)
  2. Field quick→Mechanical(Align in fixture)
  3. Permanent OSP→Fusion(Long term)
  4. Emergency restore→Mechanical(No arc)
  5. High count ribbon→Fusion mass(Match ribbon and splicer)

Splicing Methods

Fusion
Arc welds cleaved fiber ends
Mechanical
Aligns cleaved ends using gel
Cleaver
Score/break clean end
Splice Tray
Holds splice in closure
OSP Closure
Aerial/buried splice case
Splice Box
Houses and protects splices

Fiber Wavelengths

850 nm
Multimode test windowMM
1310 nm
Common singlemode test windowSM
1550 nm
Common singlemode test windowSM
1490 nm
Common GPON downstream wavelength
1625 nm
Example filtered OTDR wavelength
Loss Budget
Max allowable attenuation
Macrobend
Visible curvature can increase loss
Microbend
Small distortions can increase loss

Copper Test Parameters

NEXT
Near-end crosstalk
PSNEXT
Power sum NEXT
ACR-F
Attenuation-to-crosstalk ratio at far end
Return Loss
Higher dB means less reflected signal
Insertion Loss
Attenuation, dB
Delay Skew
Pair timing diff
Length
TDR distance check

OTDR vs Certification Scanner

OTDR

  • Fiber length
  • Fault location
  • Backscatter trace

Scanner

  • Cat 6 cert
  • NEXT/RL
  • Pass/fail report

Fiber vs copper

Tester Picker

  1. Fiber length/fault→OTDR(Backscatter)
  2. Copper length/fault→TDR(Impedance)
  3. Cat 6A cert→Certification Scanner(TIA pass/fail)
  4. End-to-end loss→OLTS(Source + meter)
  5. Visible near-end fault→VFL(Visible red light)
  6. Pair tracing→Tone Generator(Probe amp)

Test Equipment

OTDR
Optical time domain reflectometer
TDR
Copper fault distance
Certification Scanner
Validates Cat 6/6A
OLTS
Optical loss test set
OPM
Optical power meter
VFL
Visual fault locator
Tone Generator
Copper pair trace
NVP
Nominal velocity propagation

Retrofit Work

Survey
Identify active services before altering cables
Cutover
Pretest, schedule cutover, plan rollback
Abandoned cable
Verify status and local code
Closeout
Update labels and as-built records

Integrated Systems

DAS
Distributes radio coverage through several antennas
PON
Passive splitters between OLT and ONTs
Access control
Verify required door release and egress
Wireless
Check RF coverage with survey

Codes and Standards

TIA-568
Structured cabling systems and components
TIA-569
Pathways and spaces
TIA-607
Bonding/grounding standard
TIA-570
Residential cabling
Optical Fiber Code
Check locally adopted NEC edition
Communications Code
Use adopted NEC and local amendments
NFPA 70
National Electrical Code
TIA-606
Labeling, records and administration

Common Traps

Channel vs permanent

Channel includes cords ≠ PL is 90m

T568A vs B

A starts white/green ≠ B starts white/orange

OM core size

OM1 62.5um ≠ OM2-OM5 50um

Splice loss

Fusion typically lower ≠ Compare with the specified limit

Wavelength use

850 MM short ≠ 1310/1550 SM

Bonding size

6 AWG copper TBB minimum ≠ Size longer runs per TIA-607

Hands-on first

Hands-on required first ≠ Then written exam

Last Minute

  1. 1.100m channel / 90m permanent link
  2. 2.T568A WGrn,Grn,WOrg,Blu,WBlu,Org,WBrn,Brn
  3. 3.Cat5e 100MHz Cat6 250MHz Cat6A 500MHz
  4. 4.10GBASE-SR OM1 33m OM2 82m
  5. 5.10GBASE-SR OM3 300m OM4 400m
  6. 6.MM tests 850nm and 1300nm
  7. 7.SM tests 1310nm and 1550nm
  8. 8.Fusion arc, mechanical alignment fixture
  9. 9.PBB → TBB → SBB
  10. 10.Firestop F T L W ratings
  11. 11.OTDR fiber TDR copper scanner cert
  12. 12.Hands-on first, 12 tasks, 20min each
Same family resources

Explore More BICSI Certifications

Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.