Field Planning, Implementation and Design
20%of exam
Establish Pathways and Space
20%of exam
Pull Copper and Fiber Cable
12%of exam
Terminate Copper and Fiber Cable
12%of exam
Perform Splicing
6%of exam
Test Copper and Fiber Cable
7%of exam
Perform Troubleshooting
7%of exam
Perform Retrofits
5%of exam
Apply Integration and Convergence Concepts
7%of exam
Codes and Standards
4%of exam
Quick Facts
- Exam
- BICSI TECH
- Written Exam
- 100 items, mixed formats
- Written Time
- 2 hours
- Pass
- Both exams
- Hands-On First
- 12 tasks
- Task Time
- 20 min each
- Application Fee
- $335 member / $400 nonmember
- Validity
- 3 years
- Retake
- 30 days, 90 after third failure
10GBASE-SR Reach by Fiber Type
OM1 33m OM2 82m OM3 300m OM4 400m
Singlemode vs Multimode
Singlemode
- One spatial mode
- Common at 1310/1550 nm
- Long reach with compatible optics
Multimode
- 50/62.5 µm core
- Multiple modes
- Short-reach optics
Match optics, reach and loss budget
Copper Category Picker
- Up to 1GbE→Cat 5e(100 MHz)
- 5GBASE-T on a rated channel→Cat 6(250 MHz)
- 10GBASE-T on existing Cat 6→Cat 6(37–55 m depends on alien crosstalk)
- 10GbE 100m→Cat 6A(500 MHz)
- 25/40GbE 30m→Cat 8(2000 MHz)
- High EMI→Evaluate shielding or fiber(Follow the design)
Copper Categories
- Cat 5e
- 100 MHz, 2.5GBASE-T if qualified100MHz
- Cat 6
- 250 MHz, 5GBASE-T if qualified250MHz
- Cat 6A
- 500 MHz, 10GbE500MHz
- Cat 8
- 2000 MHz, 25/40GBASE-T, 30m channel2GHz
- UTP
- Unshielded twisted pair
- F/UTP
- Foil over twisted pairs
- S/FTP
- Braid + foil pairs
- AWG 22-24
- Typical conductor gauge
Cat 6 vs Cat 6A
Cat 6
- 250 MHz
- 10G reach depends on alien crosstalk
- UTP common
Cat 6A
- 500 MHz
- 10GbE 100m
- Alien crosstalk
Freq and distance
Fiber Type Picker
- Long optical link→Singlemode with rated optics(Check reach and loss budget)
- 10GBASE-SR up to 33 m→OM1(62.5um)
- 10GBASE-SR up to 82 m→OM2(50um)
- 10GBASE-SR up to 300 m→OM3(laser optimized)
- 10GBASE-SR up to 400 m→OM4(VCSEL)
- 40/100GbE short reach→Match fiber and transceiver(Check the specific optical interface)
Typical Cat 5e/6/6A Horizontal Limits
- Channel
- 100 m max100m
- Permanent Link
- 90 m max90m
- Equipment Cord
- From patch panel to equipment
- Work Area Cord
- From outlet to end device
- Consolidation Point
- Optional connection within the permanent link
- Total Cords
- 10 m total with 90m link
Permanent Link vs Channel
Permanent Link
- 90 m
- Excludes cords
- Tester adapter
Channel
- 100 m
- Includes cords
- Full end-to-end
Tester setup
Fiber Types
- OS1
- Premises singlemode performance category
- OS2
- Lower-attenuation singlemode category
- OM1
- 62.5 µm, 10GBASE-SR 33m62.5um
- OM2
- 50 µm, 10GBASE-SR 82m50um
- OM3
- 50 µm, 10GBASE-SR 300m50um
- OM4
- 50 µm, 10GBASE-SR 400m50um
- OM5
- Wideband MMF for shortwave WDM50um
- Core/Clad
- MM 50/125, 62.5/125 µm
Safety
- PPE
- Select protection for the hazard
- Lockout/Tagout
- Energy isolation
- Fiber Shard
- Sharps container dispose
- Optical Safety
- Verify dark fiber before inspection
- Ladder
- 3-point contact
- Fall Protection
- Match protection to work and location
- SDS
- Safety data sheet for chemical hazards
Project and Documentation
- As-Built
- Final installed drawings
- Test Reports
- Certification records
- Warranty
- Confirm requirements and term with manufacturer
- Blueprint
- Read plan/elevation
- RFP
- Request for proposal
- CEC
- Continuing ed credits
Firestop Ratings
F fire T temp L leak W water
Bonding and Grounding
- TBB
- Backbone conductor between bonding busbars
- Primary Bonding Busbar (PBB)
- Central ICT bonding point, formerly TMGB
- Secondary Bonding Busbar (SBB)
- Local telecom bonding point, formerly TGB
- Rack Bonding Busbar (RBB)
- Local bonding point on rack
- Riser
- Common route for a vertical TBB
- #6 AWG
- Minimum copper TBB size
- Long TBB Runs
- Size by length per TIA-607
Bonding Chain
Building ground → PBB → TBB → SBB
Firestop Systems
- F Rating
- Time resisting flame passage
- T Rating
- Time within temperature-rise limit
- L Rating
- Air leakage at specified test pressure
- W Rating
- Water resistance under specified test
- Through Penetration
- Passes fully through rated assembly
- Membrane Penetration
- One side breach
- Firestop Putty
- Match approved firestop system
- Intumescent
- Expands with heat
Pathways and Spaces
- Conduit
- Calculate fill per raceway rule
- Cable Tray
- Continuous open cable support
- Sleeve
- Wall/floor penetration
- TR
- Telecom room, equipment
- Entrance Facility (EF)
- Entry and transition for outside cabling
- ER
- Equipment room, main
- Bend Radius
- Often 4× diameter. Verify cable specs.
Cable Pulls
- Pull setup
- Check pathway, bend and pull limits
- Pull lubricant
- Use a cable-jacket-compatible product
- Air-assisted fiber
- Feeds fiber into prepared duct
- Pull line
- Install ahead of the cable
T568A Color Order
WGrn Grn WOrg Blu WBlu Org WBrn Brn
T568A vs T568B
T568A
- White/green on pin 1
- Green on pins 1–2
- Orange on pins 3 and 6
T568B
- White/orange on pin 1
- Orange on pins 1–2
- Green on pins 3 and 6
Orange/green swap
T568A/B Color Order
- T568A Pin 1
- White/Green
- T568A Pin 2
- Green
- T568A Pin 3
- White/Orange
- T568A Pin 4
- Blue
- T568A Pin 5
- White/Blue
- T568A Pin 6
- Orange
- T568A Pin 7
- White/Brown
- T568A Pin 8
- Brown
- T568B
- Swap orange/green pairs
Termination Blocks
- 110 Block
- IDC termination. Check the block’s category.
- Krone
- LSA-PLUS insulation-displacement system
- BIX
- Multi-pair IDC cross-connect system
- 66 Block
- Legacy voice IDC block
- RJ45
- 8P8C modular plug
- RJ11
- Common single-line voice jack wiring (6P2C)
- Modular Plug
- Terminates patch cord
- Jack
- Female workstation outlet
Fiber Connectors
- LC
- Small form factor, snap
- SC
- Push-pull, 2.5mm
- ST
- Bayonet, 2.5mm
- MTP
- US Conec brand of MPO connector
- MPO
- Push-on multifiber connector
- UPC
- Ultra physical contact, blue
- APC
- Angled 8 deg, green
- Polish
- Higher return loss, less reflection
Fusion vs Mechanical
Fusion
- Arc joins fiber ends
- Typically low loss
- Protect with sleeve
Mechanical
- Alignment fixture
- Often uses gel
- Useful for field repair
Check splice loss against spec
Splice Picker
- Min loss→Fusion(Verify low loss)
- Field quick→Mechanical(Align in fixture)
- Permanent OSP→Fusion(Long term)
- Emergency restore→Mechanical(No arc)
- High count ribbon→Fusion mass(Match ribbon and splicer)
Splicing Methods
- Fusion
- Arc welds cleaved fiber ends
- Mechanical
- Aligns cleaved ends using gel
- Cleaver
- Score/break clean end
- Splice Tray
- Holds splice in closure
- OSP Closure
- Aerial/buried splice case
- Splice Box
- Houses and protects splices
Fiber Wavelengths
- 850 nm
- Multimode test windowMM
- 1310 nm
- Common singlemode test windowSM
- 1550 nm
- Common singlemode test windowSM
- 1490 nm
- Common GPON downstream wavelength
- 1625 nm
- Example filtered OTDR wavelength
- Loss Budget
- Max allowable attenuation
- Macrobend
- Visible curvature can increase loss
- Microbend
- Small distortions can increase loss
Copper Test Parameters
- NEXT
- Near-end crosstalk
- PSNEXT
- Power sum NEXT
- ACR-F
- Attenuation-to-crosstalk ratio at far end
- Return Loss
- Higher dB means less reflected signal
- Insertion Loss
- Attenuation, dB
- Delay Skew
- Pair timing diff
- Length
- TDR distance check
OTDR vs Certification Scanner
OTDR
- Fiber length
- Fault location
- Backscatter trace
Scanner
- Cat 6 cert
- NEXT/RL
- Pass/fail report
Fiber vs copper
Tester Picker
- Fiber length/fault→OTDR(Backscatter)
- Copper length/fault→TDR(Impedance)
- Cat 6A cert→Certification Scanner(TIA pass/fail)
- End-to-end loss→OLTS(Source + meter)
- Visible near-end fault→VFL(Visible red light)
- Pair tracing→Tone Generator(Probe amp)
Test Equipment
- OTDR
- Optical time domain reflectometer
- TDR
- Copper fault distance
- Certification Scanner
- Validates Cat 6/6A
- OLTS
- Optical loss test set
- OPM
- Optical power meter
- VFL
- Visual fault locator
- Tone Generator
- Copper pair trace
- NVP
- Nominal velocity propagation
Retrofit Work
- Survey
- Identify active services before altering cables
- Cutover
- Pretest, schedule cutover, plan rollback
- Abandoned cable
- Verify status and local code
- Closeout
- Update labels and as-built records
Integrated Systems
- DAS
- Distributes radio coverage through several antennas
- PON
- Passive splitters between OLT and ONTs
- Access control
- Verify required door release and egress
- Wireless
- Check RF coverage with survey
Codes and Standards
- TIA-568
- Structured cabling systems and components
- TIA-569
- Pathways and spaces
- TIA-607
- Bonding/grounding standard
- TIA-570
- Residential cabling
- Optical Fiber Code
- Check locally adopted NEC edition
- Communications Code
- Use adopted NEC and local amendments
- NFPA 70
- National Electrical Code
- TIA-606
- Labeling, records and administration
Common Traps
Channel vs permanent
Channel includes cords ≠ PL is 90m
T568A vs B
A starts white/green ≠ B starts white/orange
OM core size
OM1 62.5um ≠ OM2-OM5 50um
Splice loss
Fusion typically lower ≠ Compare with the specified limit
Wavelength use
850 MM short ≠ 1310/1550 SM
Bonding size
6 AWG copper TBB minimum ≠ Size longer runs per TIA-607
Hands-on first
Hands-on required first ≠ Then written exam
Last Minute
- 1.100m channel / 90m permanent link
- 2.T568A WGrn,Grn,WOrg,Blu,WBlu,Org,WBrn,Brn
- 3.Cat5e 100MHz Cat6 250MHz Cat6A 500MHz
- 4.10GBASE-SR OM1 33m OM2 82m
- 5.10GBASE-SR OM3 300m OM4 400m
- 6.MM tests 850nm and 1300nm
- 7.SM tests 1310nm and 1550nm
- 8.Fusion arc, mechanical alignment fixture
- 9.PBB → TBB → SBB
- 10.Firestop F T L W ratings
- 11.OTDR fiber TDR copper scanner cert
- 12.Hands-on first, 12 tasks, 20min each
Explore More BICSI Certifications
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
More From This Family
Videos and articles for deeper review.