5.2 DC Working Distances, Safe Stepping & Bridging Risks
Key Takeaways
Under Handbook 17 you, and anything you are holding, must be no nearer than 1.5 metres (5 feet) to live conductor rail equipment unless a method statement and electrical risk assessment apply and their precautions are in place.
Where company instructions allow work with the conductor rail live and you will be nearer than 300 mm, place a conductor rail shield over the conductor rail if possible.
Never touch or step on conductor rail equipment, shoe gear or guard boarding, and never step between the conductor rail and the adjacent running rail.
Apply a track circuit operating clip to the running rail furthest from the conductor rail first, and place detonators on the running rail furthest from the conductor rail.
Safety boots do not insulate you from 750 V DC, and liquids touching a conductor rail become live.
5.2 DC Working Distances, Safe Stepping & Bridging Risks
Conductor rails sit at ground level, right where you walk and work. Rule Book Handbook 17, DC electrified lines (GERT8000-HB17, Issue 6 in force from 6 June 2026), sets out the personal safety rules, and section 1.4 of the PTS handbook (RT3170) summarises them for PTS holders.
What You Must Treat as Live
HB17 says conductor rail equipment (CRE: the conductor rails and anything connected to them), shoe gear and under-floor electrical equipment on trains are dangerous, and it may be fatal to touch or go near them. Treat them as live at all times unless one of the following applies:
- a planned isolation has been taken and a conductor rail permit has been issued to the COSS;
- a temporary isolation has been taken as shown in the infrastructure manager's instructions;
- a local isolation has been taken as shown in local isolation instructions;
- in an emergency, the ECO has confirmed that the CRE is safe to approach but not to touch, or the ECO has stated it is switched off and local staff have told you it is safe to approach but not to touch.
If you have live line testing equipment or a short-circuiting bar, use them before touching CRE.
Things You Must Never Do
HB17 section 3.1 says you must not:
- touch or step on CRE, shoe gear, associated exposed live train-mounted equipment or guard boarding;
- allow clothing, tools, equipment or anything you are carrying to touch them, unless the item is intended for that purpose;
- step between the conductor rail and the adjacent running rail;
- touch broken or displaced CRE;
- touch the collector shoes on any train, whether or not they are touching the conductor rail;
- step into flood water that may be in contact with the CRE or train equipment;
- direct a jet of water or any other liquid onto them.
Traction return current in the running rails is not normally dangerous, but you must not touch broken running rails or bridge the gap between them. Treat cables running alongside and crossing under the lines as live, and do not interfere with them or their covers.
The 1.5-Metre (5-Foot) Rule
Important
Keep 1.5 Metres from Live CRE HB17 section 4.1: you must make sure that you, and anything you are holding, are no nearer than 1.5 metres (5 feet) from live CRE, shoe gear and associated live train-mounted equipment, unless all of these apply: a method statement and electrical risk assessment approved by an authorised person are in place; all the specified precautions are in place; and you carry out the precautions in the method statement or company instruction.
Two further rules sit inside that exception:
- Where your company instructions allow work with the CRE live and you, or anything you are holding, will be nearer than 300 mm (1 foot), you must, if possible, place a conductor rail shield over the conductor rail before you start.
- If you must manually operate or secure points where the conductor rail is live and not gapped or protected by guard boarding next to the motor or blade, place a conductor rail shield over the conductor rail first.
Note
Why older material says "300 mm" Before Handbook 17 Issue 4 came into force on 4 June 2022, the general principle was not to let a person or anything carried come within 300 mm of live CRE. The Rule Book Briefing Leaflet for that change explains that the distance became 1.5 metres, with work closer than that allowed only under a method statement or electrical risk assessment. The PTS handbook still describes work within 0.3 metres needing approved insulated tools, shrouds or troughing, PPE and a valid, tested safe system of work: that is the 300 mm shield threshold within the 1.5 metre rule, not a general walking distance.
you and anything you hold live conductor rail
o +-----+
/|\ <---------------- 1.5 m (5 ft) ---------->| CR |
/ \ +-----+
closer only under an approved method statement and
electrical risk assessment; within 300 mm fit a
conductor rail shield if possible
Moving Materials and Attending to Vehicles
Moving materials or equipment (HB17 section 4.2): apply the precautions in the method statement or company instructions and take extreme care when holding and moving long items, using brake sticks and shunting poles, and selecting and using the correct type of electrically insulated tools and equipment. Avoid carrying materials over CRE, and never drag objects across or drop them on live CRE.
Attending to vehicles (HB17 section 4.3): if possible, work on the side furthest from live CRE when operating handbrakes, coupling or uncoupling, passing beneath buffers, going underneath or examining vehicles. If that is not possible (other than for handbrakes), first place a conductor rail shield over the conductor rail. You may examine a vehicle without the electricity being switched off as long as you do not touch the conductor rail, overhead trolley wires or equipment connected to them; after severe arcing, confirm the CRE is switched off first.
Stepping and Crossing
The PTS handbook tells you to cross the line without stepping on the rails or sleepers, walking ballast to ballast. On a line with a conductor rail that means:
| Never put your foot | Why |
|---|---|
| On the conductor rail or its ramps | It is live and its head and ramps are smooth and slippery |
| On an insulator or guard boarding | It is part of the CRE; it can break or let you slip onto the rail |
| Between the conductor rail and the adjacent running rail | HB17 forbids it; a slip can put your body across the live rail and the running rail |
| On a running rail or sleeper | The PTS handbook says walk ballast to ballast |
Where you have to cross, do so only where and when the COSS has arranged, step clear over both the conductor rail and the adjacent running rail together, and land on firm ballast.
Warning
Safety Boots Do Not Insulate You Safety boots to EN ISO 20345 protect your toes and soles, but they are not electrical insulating footwear. In wet conditions they give no reliable protection against 750 V DC.
Bridging and Arcing
Bridging happens when something conductive connects the live conductor rail to the running rail or another earthed object: a metal bar, a measuring tape, a chain, a wet rope, or a person. The result is a short circuit and an arc flash: an intense flash of heat and light, molten metal and a pressure wave that can cause severe burns, eye injuries and electrocution.
- Keep metal tools, tapes, chains and long items away from the conductor rail, and never let anything rest across it.
- The PTS handbook warns that liquids become live if they touch a conductor rail; keep clear of flood water.
- Where work near live CRE is authorised, use the insulated tools and equipment the method statement specifies. Insulated hand tools for live working are made to EN 60900, which covers tools for use up to 1,000 V AC and 1,500 V DC; inspect the insulation before use and do not use a tool with damaged insulation.
Track Circuit Operating Clips and Detonators on Conductor Rail Lines
HB17 section 4.1 and the PTS handbook add rules for emergency protection equipment:
- Apply a track circuit operating clip (or T-COD) to the running rail furthest from the conductor rail first, then to the rail nearest to it. Remove it in the reverse order: nearest rail first.
- Where there is a fourth rail, you are not able to use a track circuit operating clip.
- Place detonators on the running rail furthest from the conductor rail.
- If the emergency services need to go on or near the line and you are the person in charge at the site, tell the officer in charge of each emergency service about the conductor rail and which parts have been switched off.
Under Handbook 17 Issue 6, unless a method statement and electrical risk assessment apply, how close may you, or anything you are holding, come to live conductor rail equipment?
No nearer than 100 mm (4 inches)
No nearer than 300 mm (1 foot)
No nearer than 1.5 metres (5 feet)
No nearer than 2.75 metres (9 feet)
Which of these does Handbook 17 forbid when you are near a conductor rail?
Walking on firm ballast in the cess
Stepping between the conductor rail and the adjacent running rail
Carrying light hand tools at your side
Standing in a position of safety 1.25 metres from the nearest running rail
You need to apply a track circuit operating clip on a line with a third rail. How must you do it?
Clip the running rail furthest from the conductor rail first, then the rail nearest to it
Clip the conductor rail first, then the nearest running rail
Clip the rail nearest the conductor rail first, then the furthest rail
Clip the conductor rail to both running rails at the same time