2.2 Relays, Solenoids & Electromagnetic Controls
Key Takeaways
- Automotive relays enable low-current control switches or ECU solid-state drivers drawing 120–200 mA to switch high-current automotive loads (15A to 40A+), reducing dashboard wiring weight, eliminating cabin voltage drop, and isolating sensitive microprocessors.
- DIN 72552 establishes standard relay terminal designations: Terminal 30 is battery positive input (common contact), 87 is Normally Open (NO) output, 87a is Normally Closed (NC) output, 86 is coil positive, and 85 is coil ground/control.
- A typical 12V automotive relay coil has a resistance between 60 Ω and 100 Ω, drawing approximately 120 mA to 200 mA at nominal charging system voltage, with pick-up voltage around 7.0–8.5V and drop-out voltage around 1.5–3.5V.
- Collapsing relay coil magnetic fields generate back-EMF reverse voltage spikes of 300V to 500V; clamping diodes suppress these spikes to ~0.7V but are strictly polarity-sensitive, whereas damping resistors (470–680 Ω) clamp spikes to 20–30V and are non-polarity sensitive.
- Relays are stationary electromagnetic contact switches, whereas solenoids are electromagnetic linear actuators; starter solenoids utilize a dual-coil architecture where a high-current pull-in coil is automatically cut out once the internal contact disc energizes Terminal M.
2.2 Relays, Solenoids & Electromagnetic Controls
Electromechanical relays and solenoids form the primary muscle of automotive power distribution. Modern vehicle electronic architectures feature dozens of microprocessors (Powertrain Control Modules, Body Control Modules, Transmission Control Modules) that operate on low-power 5-Volt digital logic and low-amperage solid-state drivers. Because a microprocessor cannot directly switch a 25-Ampere radiator cooling fan or a 30-Ampere fuel pump without catastrophic silicon destruction, the automotive relay acts as an indispensable high-current interface.
Electromagnetic Switching Principles
An automotive relay is an electrically operated remote switch. It utilizes a small control current flowing through an electromagnetic coil to generate magnetic flux that physically pulls a movable soft iron armature, closing or opening heavy-duty electrical contacts.
Internal Electromechanical Relay Architecture:
[30] Common B+ Power Input
│
│ Spring Return
┌┴─┐ ┌─┐
Armature ──►│ │ │ ◄── Soft Iron Core
└┬─┘ └─┘
│ ▲
│ │ Electromagnetic Winding
┌──────────────┼────┴──────────────────────────┐
│ │ │
[86] Coil (+) │ [85] Coil (-)
Switched 12V ▼ Contact Gap ECU Low-Side Driver
o o
[87a] [87]
NC NO
Why Relays Are Essential in Automotive Engineering
- Elimination of Heavy Cabin Wiring: Without relays, heavy 10 AWG and 12 AWG copper cables would have to route through the firewall into the steering column, dashboard, and center console to supply high-amperage accessories. Relays allow heavy cables to remain short and direct under the hood, while thin 20 AWG or 22 AWG wires route low-current control signals to interior switches.
- Elimination of Circuit Voltage Drop: Long wiring runs introduce substantial series resistance ($R$). Under high current ($I$), Ohm's law ($V_{\text{drop}} = I \cdot R$) dictates severe voltage drops that starve headlights (causing yellow, dim beams) or slow down radiator cooling fans. Placing relays adjacent to loads provides maximum system voltage ($13.8,\text{V}$ to $14.4,\text{V}$) directly to the consumer.
- Protection of Electronic Control Modules: Microprocessor outputs cannot deliver high current. Relays isolate delicate module silicon from high load currents, electric motor inrush surges, and electrical noise.
ISO Relay Standards & DIN 72552 Terminal Designations
Automotive relays conform to standardized ISO Mini (approx. 25.4 mm cube) and ISO Micro footprints. Relay socket terminals are universally identified according to German industry standard DIN 72552:
| DIN Terminal | Name | Functional Circuit Connection | Electrical State |
|---|---|---|---|
| 30 | Common Contact (Wiper) | High-current battery feed from fuse/battery ($+12,\text{V}$ direct or switched) | Power input to load contacts |
| 87 | Normally Open (NO) | High-current feed to electrical load (e.g., fuel pump, horns, lights) | Open when de-energized; closed to 30 when energized |
| 87a | Normally Closed (NC) | Alternative load circuit (present only on 5-pin changeover relays) | Closed to 30 when de-energized; open when energized |
| 86 | Coil Positive | Control circuit switched positive feed ($+12,\text{V}$ ignition or relay bus) | Electromagnetic winding start |
| 85 | Coil Ground | Control circuit ground or ECU low-side driver switched return path | Electromagnetic winding end |
4-Pin vs. 5-Pin Relay Architecture
- 4-Pin Relay (Form A - Normally Open): Contains terminals 30, 87, 85, and 86. When the coil is de-energized, contacts 30 and 87 are separated by an air gap. When current energizes the coil, magnetic flux pulls the armature against spring tension, closing contact 30 to 87 and powering the load.
- 5-Pin Relay (Form C - Changeover / SPDT): Contains terminals 30, 87, 87a, 85, and 86. When de-energized, internal spring tension holds the armature firmly against terminal 87a (Normally Closed circuit). When the coil energizes, the armature pulls away from 87a and closes against terminal 87. Common applications include daytime running light (DRL) cut-off systems, A/C compressor clutch disengagement at wide-open throttle (WOT), and two-speed blower motor circuits.
Terminal Footprints (Bottom View of Relay Prongs):
4-PIN MINI ISO RELAY 5-PIN MINI ISO RELAY
┌──────────┐ ┌──────────┐
│ [86] │ │ [86] │
│ │ │ │ │ │ │ │
│[30] [87] │[30] [87]│
│ │ │ │ │ │ [87a]│ │
│ [85] │ │ ─── │
└──────────┘ │ [85] │
└──────────┘
Relay Coil Specifications & Control Topologies
The electromagnetic coil consists of hundreds of turns of ultra-fine, varnish-insulated copper magnet wire wound around a soft iron pole piece.
- Coil Resistance: On standard 12V automotive relays, healthy coil resistance measures between 60 $\Omega$ and 100 $\Omega$ (typically 75 $\Omega$ to 85 $\Omega$ at room temperature).
- Coil Current Draw: Applying Ohm's law at typical alternator operating voltage ($13.8,\text{V}$):
- Pull-in (Pick-up) Voltage: The minimum voltage required to generate sufficient magnetic flux to overcome mechanical spring tension and close the contacts—typically 7.0V to 8.5V on a 12V system.
- Drop-out (Release) Voltage: The voltage threshold where the decaying magnetic field allows the spring to snap the armature open—typically 1.5V to 3.5V.
High-Side vs. Low-Side Switching
Automotive manufacturers utilize two primary relay control schemes:
- High-Side Switching: Terminal 85 is permanently connected to vehicle chassis ground. The dashboard switch or power module applies switched $+12,\text{V}$ to Terminal 86 to energize the relay.
- Low-Side Switching (Modern OEM Standard): Terminal 86 is supplied with constant $+12,\text{V}$ from an ignition fuse. Terminal 85 routes back to an electronic control module (ECM/BCM), where an internal solid-state N-channel MOSFET or NPN bipolar transistor switches Terminal 85 to ground. Low-side switching minimizes the risk of short-to-ground faults in the harness causing unintended component activation.
Coil Suppression Devices: Clamping Diodes vs. Damping Resistors
When a relay coil is energized, an intense electromagnetic field is stored in its inductive core ($E = \frac{1}{2} L I^2$). When the control switch or module driver suddenly opens, current instantly drops to zero. According to Faraday's and Lenz's laws of electromagnetic induction:
Because the current collapses in microseconds ($dt \to 0$), the collapsing magnetic field induces a massive reverse-polarity voltage spike—known as inductive kick, flyback voltage, or back-EMF—measuring 300 Volts to over 500 Volts!
This 400V+ spike travels directly down the control harness into the ECU, instantly puncturing the microscopic silicon P-N junctions of the module's driver transistors. To prevent this destruction, suppression devices are built into the relay housing across terminals 85 and 86.
Coil Suppression Methods:
A. CLAMPING / QUENCHING DIODE B. DAMPING RESISTOR SUPPRESSION
[86] (+) Switched 12V [86] Switched 12V
│ │
├───┬─────────────┐ ├───┬─────────────┐
│ │ │ │ │ │
│ ▼ Cathode │ │ ┌───┐ │
│ ─── Diode │ Coil │ │ R │ 560 Ω │ Coil
│ ▲ Anode │ 80 Ω │ └───┘ │ 80 Ω
│ │ │ │ │ │
├───┴─────────────┘ ├───┴─────────────┘
│ │
[85] (-) ECU Low-Side Driver [85] ECU Low-Side Driver
*STRICTLY POLARITY SENSITIVE!* *NON-POLARITY SENSITIVE!*
1. Clamping Diode (Flyback / Quenching Diode)
- Internal Connection: A silicon rectifier diode is connected in parallel across the coil. The cathode (banded end) connects to Terminal 86 ($+12,\text{V}$), and the anode connects to Terminal 85 (ground).
- Operation: Under normal operation, the diode is reverse-biased (12V on cathode, 0V on anode) and acts as an open circuit, drawing no current. When the control circuit opens, the collapsing magnetic field reverses the coil's polarity: Terminal 85 spikes positive relative to Terminal 86. This instantaneously forward-biases the diode.
- Spike Clamping: The diode conducts, routing the inductive discharge in a closed loop through the coil winding and clamping the spike to the diode's forward voltage drop: approximately 0.7 Volts.
[!CAUTION] The Polarity Reversal Trap: Diode-suppressed relays are strictly polarity-sensitive. If a diode-suppressed relay is plugged into a socket wired in reverse (Terminal 85 powered with $+12,\text{V}$ and Terminal 86 grounded), the diode is forward-biased across full battery voltage. The moment the control switch closes, the diode acts as a dead short across the power supply, instantly vaporizing the diode, blowing the control circuit fuse, or destroying the ECU's driver stage!
2. Damping Resistor
- Internal Connection: A carbon or metal-film resistor—typically 470 $\Omega$ to 680 $\Omega$, 0.5 Watt—is connected in parallel across terminals 85 and 86.
- Operation: When the coil de-energizes, the inductive flyback energy discharges through the parallel resistor. While it does not clamp the spike to 0.7V like a diode, it safely dampens the surge down to 20V to 30V, which standard automotive ECUs can easily absorb without damage.
- Key Advantage: Resistors have no polarity. A resistor-suppressed relay can be inserted into high-side or low-side switched circuits without any risk of short circuits regardless of which terminal receives positive voltage.
Technical Comparison: Clamping Diode vs. Damping Resistor
| Technical Feature | Clamping Diode | Damping Resistor |
|---|---|---|
| Spike Suppression Level | Clamps spike to ~0.7V | Dampens spike to 20V–30V |
| Polarity Sensitivity | Strictly polarity-sensitive | Non-polarity sensitive |
| Reverse Socket Risk | Dead short circuit; blown fuse / fried ECU | Safe; operates normally in either orientation |
| Contact Release Time | Slightly delayed (extended arc) | Rapid, crisp contact opening |
| OEM Application | Dedicated OEM computer-controlled circuits | Universal replacement relays, aftermarket harnesses |
Solenoids vs. Relays: Electromechanical Comparison
Technicians must clearly distinguish between relays and solenoids:
- Relay: An electromagnetic device that operates stationary electrical contacts to switch external electrical circuits; it performs no external mechanical work.
- Solenoid: An electromechanical actuator that converts electrical energy into linear mechanical motion via a movable soft iron plunger.
Starter Solenoid Dual-Coil Architecture:
[Terminal 50] (From Starter Relay / Ignition 'START')
│
┌───────────────┴───────────────┐
│ │
▼ Pull-In Coil ▼ Hold-In Coil
(Heavy Wire: 0.3 Ω, 35A) (Fine Wire: 0.9 Ω, 10A)
│ │
▼ ▼
[Terminal M] [Solenoid Case / Ground]
(Starter Motor Field Coils) │
│ ════ Ground
▼ Brushes & Armature
════ Ground
*When Contact Disc Bridges [30] to [M]: Pull-In Coil is shorted out on both ends!
Hold-In Coil retains plunger while motor cranks at 200A+.*
The Dual-Coil Starter Solenoid
The automotive starter solenoid performs two essential functions simultaneously:
- Mechanical: The movable plunger pulls a mechanical shift lever (fork), sliding the starter drive pinion gear into physical mesh with the flywheel/flexplate ring gear.
- Electrical: At the end of plunger travel, a heavy copper contact disc bridges Terminal 30 (heavy battery cable) to Terminal M (starter motor armature brushes), delivering 150A to 400A+ of cranking current.
To accomplish this efficiently without burning out the coil, the starter solenoid incorporates two distinct internal windings:
- Pull-In Coil: Wound with thick copper wire having low electrical resistance ($~0.2,\Omega$ to $0.3,\Omega$). Drawing 30 to 40 Amperes, it produces the massive magnetic flux required to accelerate the heavy iron plunger against the return spring and engage the flywheel gear.
- Electrical Return: The pull-in coil does not ground to the case; its negative end connects to Terminal M, grounding through the starter motor's internal brushes and armature.
- Hold-In Coil: Wound with fine copper wire having higher resistance ($~0.8,\Omega$ to $1.0,\Omega$). Drawing only 8 to 12 Amperes, it produces just enough magnetic force to hold the plunger firmly in place.
- Electrical Return: Connects directly from Terminal 50 to the metal solenoid case ground.
The Automatic Cut-Out Sequence: When the plunger reaches full stroke, the copper disc contacts Terminal 30 and Terminal M, applying full $+12,\text{V}$ battery power to the starter motor. Because Terminal M is now energized with $+12,\text{V}$, both ends of the pull-in coil are at equal electrical potential ($+12,\text{V}$ at Terminal 50, $+12,\text{V}$ at Terminal M). This automatically shuts off the pull-in coil, saving 35A of battery energy during cranking while the low-draw hold-in coil maintains contact!
Diagnostic Testing of Automotive Relays
Loaded Contact Voltage Drop Test
Never judge an automotive relay simply because it "clicks." A relay with severely pitted, carbon-coated, or oxidized silver contacts can click loudly when energized yet drop several volts across its contacts under load, starving an electric fuel pump or cooling fan.
Measuring Contact Voltage Drop Under Operating Load:
┌──────────────────────────────────┐
│ OPERATING RELAY │
│ │
B+ Supply ──►│ [30] [87] │──► High-Current Load
└─┬──────────────────────────────┬─┘ (e.g., Fuel Pump)
│ │
└──( + ) DMM VOLTMETER ( - )───┘
TEST SPECIFICATION: DMM reading must be <= 0.2V DC (200 mV) under full load!
Reading > 0.2V indicates pitted, burned, or high-resistance relay contacts.
- Ensure the relay is plugged in, energized, and the consumer load is operating.
- Set the DMM to DC Volts (or millivolts).
- Connect the DMM red lead to Terminal 30 and the black lead to Terminal 87.
- Evaluate the Reading:
- Good Contacts: Voltage drop is $\le 0.20,\text{V}$ (200 mV), typically under $50,\text{mV}$.
- Defective Contacts: A reading exceeding $0.20,\text{V}$ indicates contact pitting, erosion, or carbonization. The relay must be replaced.
Bench Testing Procedures
- Coil Resistance Measurement: Using an ohmmeter, measure resistance between terminals 85 and 86. A healthy 12V coil reads between $60,\Omega$ and $100,\Omega$. A reading of $0,\Omega$ indicates a shorted coil; an infinite reading (OL) indicates an open coil winding.
- Suppression Diode Test: Set DMM to Diode Test mode. Connect red lead to 85 and black lead to 86. A healthy diode reads approximately $0.6,\text{V}$ to $0.7,\text{V}$. Reverse the leads (red to 86, black to 85); the DMM must read Over-Limit (OL). If it reads $0.0,\text{V}$ in both directions, the internal diode is shorted.
How does a quenching diode compare with a damping resistor when used for inductive coil spike suppression in automotive relays?
In an automotive starter solenoid, how does the high-current pull-in coil automatically de-energize once the starter motor begins cranking?
A technician suspects excessive contact resistance in an energized fuel pump relay while the fuel pump is running. Where should the digital multimeter (DMM) leads be connected, and what is the maximum allowable voltage drop reading?