14.1 Units of Measurement, Uncertainty, and Significant Figures
Key Takeaways
The International System of Units (SI) establishes seven fundamental base units—meter (m), kilogram (kg), second (s), kelvin (K), mole (mol), ampere (A), and candela (cd)—from which all chemical quantities such as volume, density, and pressure are derived.
When a clear analog scale permits interpolation, estimate one digit beyond its markings. Determine measurement uncertainty from the instrument, method and repeatability.
Read the specified part of the meniscus at eye level. Use the bottom for a clear, concave water meniscus in ordinary glassware.
Interior zeros are significant and leading zeros are placeholders. Use scientific notation to make trailing zeros in whole numbers unambiguous.
In classroom calculations, add or subtract to the least certain decimal place and multiply or divide to the fewest significant figures. For pH from dilute concentration, match the number of decimal places to the concentration’s significant figures.
14.1 Units of Measurement, Uncertainty, and Significant Figures
Praxis Chemistry Core Focus: Quantitative rigor in the laboratory is a major competency assessed on the Praxis Chemistry (5246) examination. Candidates must demonstrate proficiency in manipulating International System of Units (SI) base and derived units, executing dimensional analysis factor-label conversions, reading analog laboratory apparatus to the appropriate limit of uncertainty, properly accounting for meniscus curvature and parallax error, and applying significant figure conventions across arithmetic and logarithmic calculations (such as and ).
1. The International System of Units (SI) and Derived Units
The International System of Units (SI) defines its units by fixing the numerical values of seven defining constants. The BIPM SI Brochure distinguishes base, derived, and non-SI units.
The Seven SI Base Units
| Physical Quantity | SI Base Unit | Symbol | Physical Basis / Constant |
|---|---|---|---|
| Length | meter | Distance light travels in vacuum in | |
| Mass | kilogram | Defined via the Planck constant () | |
| Time | second | Unperturbed ground-state hyperfine transition frequency of , | |
| Thermodynamic Temperature | kelvin | Defined via the Boltzmann constant () | |
| Amount of Substance | mole | Exactly elementary entities (Avogadro constant ) | |
| Electric Current | ampere | Elementary charge () | |
| Luminous Intensity | candela | Luminous efficacy of at |
Note
Pedagogical Nuances on SI Units:
- The kilogram () is the only SI base unit that includes a metric prefix (-) in its name and symbol. In chemical laboratory calculations, the gram () is widely used as a practical working unit, but the kilogram remains the official SI base standard.
- The kelvin () is an absolute temperature scale that begins at absolute zero (). Temperatures in kelvins are expressed without a degree symbol (e.g., , not ). The temperature interval is identical in magnitude to : .
Metric Prefixes
Metric prefixes modify SI units by powers of ten, facilitating concise communication across atomic and macroscopic dimensions:
| Prefix | Symbol | Multiplier | Scientific Notation | Example in Chemistry |
|---|---|---|---|---|
| Giga- | (spectroscopy) | |||
| Mega- | (lattice energies) | |||
| Kilo- | (enthalpy of reaction) | |||
| Deci- | ; | |||
| Centi- | (bond lengths) | |||
| Milli- | (titration volumes) | |||
| Micro- | (colloidal particles) | |||
| Nano- | (wavelength of light) | |||
| Pico- | (atomic/ionic radii) |
Derived Units in Chemistry
Derived units are algebraic combinations of the seven base units:
- Volume (): The SI derived unit of volume is the cubic meter (). Because is too large for standard laboratory glassware, chemists utilize the liter () and milliliter (): The liter is a non-SI name for the cubic decimeter, and .
- Density (): Defined as mass per unit volume (). The SI unit is , but laboratory chemists typically express density in (or ) for liquids and solids, and for gases. Specify temperature and pressure where they matter, especially for gases.
- Pressure (): Defined as force per unit area (). The SI derived unit is the Pascal (), equivalent to . For ordinary laboratory calculations, is approximately . The standard atmosphere has the exact conversions:
Dimensional Analysis (The Factor-Label Method)
Dimensional analysis treats units as algebraic quantities that multiply, divide, and cancel. Problem-solving involves constructing conversion factors whose value equals unity ():
Worked Example: Multi-Step Metric Conversion
Convert the density of mercury, , to the official SI unit of :
2. Measurement Uncertainty and Reading Analog Instruments
Instrument calibration, resolution, the reading method and environmental conditions can all affect a measurement. For classroom exercises using a clear analog scale, record the marked digits and estimate an additional digit when the scale permits it. With spacing in a burette, a meniscus four-fifths of the way down from to is about .
| Scale example | Reading convention for the exercise |
|---|---|
| Burette marked every | Interpolate to where the meniscus and scale are clear. The delivered volume is the difference between final and initial readings. |
| Graduated cylinder marked every | If tenths can be read, report for a meniscus on the line. |
| Ruler marked every | Estimate a fraction of a millimeter only if the markings and endpoint allow it. |
| Digital balance | Read the stable display and use the model’s certified performance and verification results to evaluate uncertainty. |
The estimated digit indicates how the reading was recorded. Evaluate uncertainty separately from scale resolution, device tolerance, repeatability, conditions and the measurement method. NIST burette calibration and meniscus methods · International Vocabulary of Metrology
Meniscus Formation and Parallax Error
When an aqueous solution is placed inside a glass vessel, water usually wets the walls. The surface is curved, with its center lower than its edges.
- Concave Meniscus (Water, Aqueous Solutions): Read the bottom of a clear concave meniscus when the glassware uses that convention.
- Convex Meniscus (Liquid Mercury): A nonwetting liquid can form a convex meniscus. Read the top if the approved method calls for it.
PARALLAX ERROR GEOMETRY
Observer High (Looking Down)
\
\ (Apparent line: reads TOO HIGH in cylinder,
\ reads TOO LOW in top-down burette)
▼
───────────╭─────╮─────────── ◄── Scale Line
│ │
Eye Level │ ● │ ◄────────── TRUE READING (Bottom of Meniscus)
│ │
───────────╰─────╯─────────── ◄── Scale Line
▲
/
/ (Apparent line: reads TOO LOW in cylinder,
/ reads TOO HIGH in top-down burette)
Observer Low (Looking Up)
Caution
Parallax Error Mechanism: Parallax error is an apparent shift in the position of an object when viewed from different angles. To eliminate parallax:
- The observer's eye must be placed in a direct horizontal plane perpendicular to the scale markings.
- If the observer looks down at a graduated cylinder, the bottom of the meniscus projects against a calibration line above its true position, yielding an artificially high reading.
- Conversely, looking up projects the meniscus against a lower mark, yielding an artificially low reading.
- In a burette (where zero is at the top and numbers increase downward), looking down causes an artificially low volume reading, which leads to systematic errors in titration calculations!
3. Significant Figure Rules and Conventions
Significant figures convey the precision of an experimental measurement. Reported digits describe a chosen reporting resolution and should be consistent with the known uncertainty.
Identification Rules
- Nonzero Digits: All nonzero integers ( through ) are always significant.
- has significant figures.
- Leading Zeros (Placeholders): Zeros that precede all nonzero digits serve merely to locate the decimal point; they are never significant.
- has significant figures ( and ). In scientific notation, this is written .
- Captive (Interior) Zeros: Zeros situated between nonzero digits are always significant.
- has significant figures.
- has significant figures.
- Trailing Zeros: Trailing zeros after a decimal point can record significant digits. Trailing zeros in a whole number without a decimal marker can be ambiguous.
- is ambiguous without more context. Write to specify two significant figures.
- (with decimal point) has significant figures.
- has significant figures.
- unambiguously indicates significant figures.
- Exact Numbers: Quantities obtained from direct counting of discrete objects (e.g., test tubes, titration trials) or defined mathematical relationships (e.g., , , ) are exact for these calculations and do not limit rounding.
Significant Figures Decision Matrix
| Measured Value | Number of Sig Figs | Justification |
|---|---|---|
| Leading zeros () insignificant; captive none; trailing zero after decimal significant () | ||
| All digits significant (nonzero digits and captive zeros) | ||
| Ambiguous | Use scientific notation to specify the intended number of digits | |
| Explicit decimal point makes trailing zeros significant | ||
| All digits in the coefficient of scientific notation are significant () | ||
| Exact | Exact counting definition; does not limit mathematical precision |
4. Mathematical Operations and Rounding Conventions
These rounding rules are classroom conventions for reporting calculations with measured inputs. A full uncertainty analysis considers how each input affects the result.
Addition and Subtraction: Decimal Place Rule
The result of addition or subtraction is limited by the measurement having the fewest number of decimal places (the greatest absolute uncertainty / least certain place value), not by the total number of significant figures.
Example: Combining Laboratory Masses
Calculate the total mass of three solid samples: :
Multiplication and Division: Fewest Significant Figures Rule
The result of multiplication or division must be rounded to contain the same number of significant figures as the measurement with the fewest total significant figures.
Example: Density Determination
A mineral specimen has a mass of ( sig figs) and a displaced volume of ( sig figs):
Tip
Guard Digits in Multi-Step Calculations: When performing multi-step laboratory calculations, carry at least two extra guard digits (or retain all internal calculator digits) through intermediate steps. Round only once at the final step to the correct number of significant figures. Premature rounding can change the final answer.
Significant Figures on Logarithmic Scales (pH and pOH)
The thermodynamic pH is of hydrogen-ion activity. For the dilute-solution approximation used here, insert the numerical molarity relative to . For concentration calculations using base-10 logarithms, match the number of decimal places in pH to the significant figures in the concentration. IUPAC pH definition
Worked Example: Concentration to pH
Calculate the of a solution where ( significant figures):
The concentration contains three significant figures, so report with three decimal places under the stated approximation.
Worked Example: pH to Concentration
Calculate the for a solution with ( decimal places):
On a burette marked every 0.1 mL, the meniscus is about four-fifths of the way down from 24.3 mL to 24.4 mL. The scale and meniscus are clear enough to estimate one additional digit. What reading should be recorded?
24.4 mL
24.38 mL
24.375 mL
24.400 mL
A student determines the density of an irregularly shaped mineral sample. The mass of the mineral is measured on an analytical balance as 14.825 g. The initial volume of water in a graduated cylinder is 22.4 mL, and after completely submerging the insoluble mineral without trapping bubbles, the water level rises to 28.1 mL. What is the calculated density of the mineral sample reported to the correct number of significant figures?
2.6009 g/mL
2.60 g/mL
2.6 g/mL
3 g/mL
A solution of hydrochloric acid is measured to have a hydronium ion concentration of [H₃O⁺] = 4.80 × 10⁻⁴ M. Using the dilute-solution approximation, what is the pH of this solution reported to the correct number of significant figures?
3.319
3.32
3.3
3.3188
Sections you finish are checked off in the contents.