14.1 Units of Measurement, Uncertainty, and Significant Figures

Key Takeaways

  • The International System of Units (SI) establishes seven fundamental base units—meter (m), kilogram (kg), second (s), kelvin (K), mole (mol), ampere (A), and candela (cd)—from which all chemical quantities such as volume, density, and pressure are derived.

  • When a clear analog scale permits interpolation, estimate one digit beyond its markings. Determine measurement uncertainty from the instrument, method and repeatability.

  • Read the specified part of the meniscus at eye level. Use the bottom for a clear, concave water meniscus in ordinary glassware.

  • Interior zeros are significant and leading zeros are placeholders. Use scientific notation to make trailing zeros in whole numbers unambiguous.

  • In classroom calculations, add or subtract to the least certain decimal place and multiply or divide to the fewest significant figures. For pH from dilute concentration, match the number of decimal places to the concentration’s significant figures.

Last updated: November 2026

14.1 Units of Measurement, Uncertainty, and Significant Figures

Praxis Chemistry Core Focus: Quantitative rigor in the laboratory is a major competency assessed on the Praxis Chemistry (5246) examination. Candidates must demonstrate proficiency in manipulating International System of Units (SI) base and derived units, executing dimensional analysis factor-label conversions, reading analog laboratory apparatus to the appropriate limit of uncertainty, properly accounting for meniscus curvature and parallax error, and applying significant figure conventions across arithmetic and logarithmic calculations (such as pH\text{pH} and pOH\text{pOH}).


1. The International System of Units (SI) and Derived Units

The International System of Units (SI) defines its units by fixing the numerical values of seven defining constants. The BIPM SI Brochure distinguishes base, derived, and non-SI units.

The Seven SI Base Units

Physical QuantitySI Base UnitSymbolPhysical Basis / Constant
Lengthmeterm\text{m}Distance light travels in vacuum in 1/299,792,458 s1 / 299,792,458\text{ s}
Masskilogramkg\text{kg}Defined via the Planck constant (h=6.62607015×10−34 J⋅sh = 6.62607015 \times 10^{-34}\text{ J}\cdot\text{s})
Timeseconds\text{s}Unperturbed ground-state hyperfine transition frequency of 133Cs^{133}\text{Cs}, 9192631770 Hz9192631770\text{ Hz}
Thermodynamic TemperaturekelvinK\text{K}Defined via the Boltzmann constant (k=1.380649×10−23 J/Kk = 1.380649 \times 10^{-23}\text{ J/K})
Amount of Substancemolemol\text{mol}Exactly 6.02214076×10236.02214076 \times 10^{23} elementary entities (Avogadro constant NAN_A)
Electric CurrentampereA\text{A}Elementary charge (e=1.602176634×10−19 Ce = 1.602176634 \times 10^{-19}\text{ C})
Luminous Intensitycandelacd\text{cd}Luminous efficacy of 683 lm/W683\text{ lm/W} at 540×1012 Hz540 \times 10^{12}\text{ Hz}

Note

Pedagogical Nuances on SI Units:

  1. The kilogram (kg\text{kg}) is the only SI base unit that includes a metric prefix (kilokilo-) in its name and symbol. In chemical laboratory calculations, the gram (g=10−3 kg\text{g} = 10^{-3}\text{ kg}) is widely used as a practical working unit, but the kilogram remains the official SI base standard.
  2. The kelvin (K\text{K}) is an absolute temperature scale that begins at absolute zero (0 K=−273.15∘C0\text{ K} = -273.15^\circ\text{C}). Temperatures in kelvins are expressed without a degree symbol (e.g., 298.15 K298.15\text{ K}, not 298.15∘K298.15^\circ\text{K}). The temperature interval 1 K1\text{ K} is identical in magnitude to 1∘C1^\circ\text{C}: T(K)=T(∘C)+273.15T(\text{K}) = T(^\circ\text{C}) + 273.15.

Metric Prefixes

Metric prefixes modify SI units by powers of ten, facilitating concise communication across atomic and macroscopic dimensions:

PrefixSymbolMultiplierScientific NotationExample in Chemistry
Giga-G\text{G}1,000,000,0001,000,000,00010910^91 GHz=109 s−11\text{ GHz} = 10^9\text{ s}^{-1} (spectroscopy)
Mega-M\text{M}1,000,0001,000,00010610^61 MJ=106 J1\text{ MJ} = 10^6\text{ J} (lattice energies)
Kilo-k\text{k}1,0001,00010310^31 kJ=103 J1\text{ kJ} = 10^3\text{ J} (enthalpy of reaction)
Deci-d\text{d}0.10.110−110^{-1}1 dm=0.1 m1\text{ dm} = 0.1\text{ m}; 1 dm3=1 L1\text{ dm}^3 = 1\text{ L}
Centi-c\text{c}0.010.0110−210^{-2}1 cm=0.01 m1\text{ cm} = 0.01\text{ m} (bond lengths)
Milli-m\text{m}0.0010.00110−310^{-3}1 mL=10−3 L1\text{ mL} = 10^{-3}\text{ L} (titration volumes)
Micro-μ\mu0.0000010.00000110−610^{-6}1 μm=10−6 m1\ \mu\text{m} = 10^{-6}\text{ m} (colloidal particles)
Nano-n\text{n}0.0000000010.00000000110−910^{-9}1 nm=10−9 m1\text{ nm} = 10^{-9}\text{ m} (wavelength of light)
Pico-p\text{p}0.0000000000010.00000000000110−1210^{-12}1 pm=10−12 m1\text{ pm} = 10^{-12}\text{ m} (atomic/ionic radii)

Derived Units in Chemistry

Derived units are algebraic combinations of the seven base units:

  1. Volume (VV): The SI derived unit of volume is the cubic meter (m3\text{m}^3). Because 1 m31\text{ m}^3 is too large for standard laboratory glassware, chemists utilize the liter (L\text{L}) and milliliter (mL\text{mL}): 1 L=1 dm3=10−3 m3=1000 mL=1000 cm31\text{ L} = 1\text{ dm}^3 = 10^{-3}\text{ m}^3 = 1000\text{ mL} = 1000\text{ cm}^3 The liter is a non-SI name for the cubic decimeter, and 1 mL=1 cm31\text{ mL} = 1\text{ cm}^3.
  2. Density (ρ\rho): Defined as mass per unit volume (ρ=m/V\rho = m / V). The SI unit is kg/m3\text{kg/m}^3, but laboratory chemists typically express density in g/cm3\text{g/cm}^3 (or g/mL\text{g/mL}) for liquids and solids, and g/L\text{g/L} for gases. Specify temperature and pressure where they matter, especially for gases.
  3. Pressure (PP): Defined as force per unit area (P=F/AP = F / A). The SI derived unit is the Pascal (Pa\text{Pa}), equivalent to 1 N/m2=1 kg⋅m−1⋅s−21\text{ N/m}^2 = 1\text{ kg}\cdot\text{m}^{-1}\cdot\text{s}^{-2}. For ordinary laboratory calculations, 1 torr1\text{ torr} is approximately 1 mmHg1\text{ mmHg}. The standard atmosphere has the exact conversions: 1 atm=101.325 kPa=101325 Pa=760 torr=1.01325 bar1\text{ atm} = 101.325\text{ kPa} = 101325\text{ Pa} = 760\text{ torr} = 1.01325\text{ bar}

Dimensional Analysis (The Factor-Label Method)

Dimensional analysis treats units as algebraic quantities that multiply, divide, and cancel. Problem-solving involves constructing conversion factors whose value equals unity (11):

Given Quantity×(Desired UnitGiven Unit)=Desired Quantity\text{Given Quantity} \times \left(\frac{\text{Desired Unit}}{\text{Given Unit}}\right) = \text{Desired Quantity}

Worked Example: Multi-Step Metric Conversion

Convert the density of mercury, 13.6 g/cm313.6\text{ g/cm}^3, to the official SI unit of kg/m3\text{kg/m}^3:

13.6 g1 cm3×(1 kg1000 g)×(100 cm1 m)3=13.6 g1 cm3×1 kg1000 g×106 cm31 m3=1.36×104 kg/m3\frac{13.6\text{ g}}{1\text{ cm}^3} \times \left(\frac{1\text{ kg}}{1000\text{ g}}\right) \times \left(\frac{100\text{ cm}}{1\text{ m}}\right)^3 = \frac{13.6\text{ g}}{1\text{ cm}^3} \times \frac{1\text{ kg}}{1000\text{ g}} \times \frac{10^6\text{ cm}^3}{1\text{ m}^3} = 1.36 \times 10^4\text{ kg/m}^3


2. Measurement Uncertainty and Reading Analog Instruments

Instrument calibration, resolution, the reading method and environmental conditions can all affect a measurement. For classroom exercises using a clear analog scale, record the marked digits and estimate an additional digit when the scale permits it. With 0.10 mL0.10\text{ mL} spacing in a burette, a meniscus four-fifths of the way down from 24.324.3 to 24.4 mL24.4\text{ mL} is about 24.38 mL24.38\text{ mL}.

Scale exampleReading convention for the exercise
Burette marked every 0.1 mL0.1\text{ mL}Interpolate to 0.01 mL0.01\text{ mL} where the meniscus and scale are clear. The delivered volume is the difference between final and initial readings.
Graduated cylinder marked every 1 mL1\text{ mL}If tenths can be read, report 43.0 mL43.0\text{ mL} for a meniscus on the 43 mL43\text{ mL} line.
Ruler marked every 1 mm1\text{ mm}Estimate a fraction of a millimeter only if the markings and endpoint allow it.
Digital balanceRead the stable display and use the model’s certified performance and verification results to evaluate uncertainty.

The estimated digit indicates how the reading was recorded. Evaluate uncertainty separately from scale resolution, device tolerance, repeatability, conditions and the measurement method. NIST burette calibration and meniscus methods · International Vocabulary of Metrology

Meniscus Formation and Parallax Error

When an aqueous solution is placed inside a glass vessel, water usually wets the walls. The surface is curved, with its center lower than its edges.

  • Concave Meniscus (Water, Aqueous Solutions): Read the bottom of a clear concave meniscus when the glassware uses that convention.
  • Convex Meniscus (Liquid Mercury): A nonwetting liquid can form a convex meniscus. Read the top if the approved method calls for it.
                         PARALLAX ERROR GEOMETRY

       Observer High (Looking Down)
               \ 
                \  (Apparent line: reads TOO HIGH in cylinder,
                 \  reads TOO LOW in top-down burette)
                  ▼
       ───────────╭─────╮─────────── ◄── Scale Line
                  │     │
       Eye Level  │  ●  │ ◄────────── TRUE READING (Bottom of Meniscus)
                  │     │
       ───────────╰─────╯─────────── ◄── Scale Line
                  ▲
                 / 
                /  (Apparent line: reads TOO LOW in cylinder,
               /   reads TOO HIGH in top-down burette)
       Observer Low (Looking Up)

Caution

Parallax Error Mechanism: Parallax error is an apparent shift in the position of an object when viewed from different angles. To eliminate parallax:

  • The observer's eye must be placed in a direct horizontal plane perpendicular to the scale markings.
  • If the observer looks down at a graduated cylinder, the bottom of the meniscus projects against a calibration line above its true position, yielding an artificially high reading.
  • Conversely, looking up projects the meniscus against a lower mark, yielding an artificially low reading.
  • In a burette (where zero is at the top and numbers increase downward), looking down causes an artificially low volume reading, which leads to systematic errors in titration calculations!

3. Significant Figure Rules and Conventions

Significant figures convey the precision of an experimental measurement. Reported digits describe a chosen reporting resolution and should be consistent with the known uncertainty.

Identification Rules

  1. Nonzero Digits: All nonzero integers (11 through 99) are always significant.
    • 348.2 g348.2\text{ g} has 44 significant figures.
  2. Leading Zeros (Placeholders): Zeros that precede all nonzero digits serve merely to locate the decimal point; they are never significant.
    • 0.00045 M0.00045\text{ M} has 22 significant figures (44 and 55). In scientific notation, this is written 4.5×10−4 M4.5 \times 10^{-4}\text{ M}.
  3. Captive (Interior) Zeros: Zeros situated between nonzero digits are always significant.
    • 4005 mL4005\text{ mL} has 44 significant figures.
    • 1.008 g/mol1.008\text{ g/mol} has 44 significant figures.
  4. Trailing Zeros: Trailing zeros after a decimal point can record significant digits. Trailing zeros in a whole number without a decimal marker can be ambiguous.
    • 4500 mL4500\text{ mL} is ambiguous without more context. Write 4.5×103 mL4.5\times10^3\text{ mL} to specify two significant figures.
    • 4500. mL4500.\text{ mL} (with decimal point) has 44 significant figures.
    • 45.00 g45.00\text{ g} has 44 significant figures.
    • 4.50×103 mL4.50 \times 10^3\text{ mL} unambiguously indicates 33 significant figures.
  5. Exact Numbers: Quantities obtained from direct counting of discrete objects (e.g., 1212 test tubes, 33 titration trials) or defined mathematical relationships (e.g., 1 in=2.54 cm1\text{ in} = 2.54\text{ cm}, 1000 mL=1 L1000\text{ mL} = 1\text{ L}, stoichiometric coefficients\text{stoichiometric coefficients}) are exact for these calculations and do not limit rounding.

Significant Figures Decision Matrix

Measured ValueNumber of Sig FigsJustification
0.00350 kg0.00350\text{ kg}33Leading zeros (0.000.00) insignificant; captive none; trailing zero after decimal significant (3,5,03, 5, 0)
502.04 mL502.04\text{ mL}55All digits significant (nonzero digits and captive zeros)
72,000 Pa72,000\text{ Pa}AmbiguousUse scientific notation to specify the intended number of digits
72,000. Pa72,000.\text{ Pa}55Explicit decimal point makes trailing zeros significant
1.080×10−3 M1.080 \times 10^{-3}\text{ M}44All digits in the coefficient of scientific notation are significant (1,0,8,01, 0, 8, 0)
1 dozen=121\text{ dozen} = 12ExactExact counting definition; does not limit mathematical precision

4. Mathematical Operations and Rounding Conventions

These rounding rules are classroom conventions for reporting calculations with measured inputs. A full uncertainty analysis considers how each input affects the result.

Addition and Subtraction: Decimal Place Rule

The result of addition or subtraction is limited by the measurement having the fewest number of decimal places (the greatest absolute uncertainty / least certain place value), not by the total number of significant figures.

Example: Combining Laboratory Masses

Calculate the total mass of three solid samples: 125.1 g+3.428 g+0.052 g125.1\text{ g} + 3.428\text{ g} + 0.052\text{ g}:

125.1g (uncertainty in tenths place, 1 decimal place)3.428g (3 decimal places)+0.052g (3 decimal places)128.580g (unrounded sum)128.6g (rounded to 1 decimal place)\begin{array}{rl} 125.1 & \text{g (uncertainty in tenths place, 1 decimal place)} \\ 3.428 & \text{g (3 decimal places)} \\ +\quad 0.052 & \text{g (3 decimal places)} \\ \hline 128.580 & \text{g (unrounded sum)} \\ \mathbf{128.6} & \mathbf{\text{g (rounded to 1 decimal place)}} \end{array}

Multiplication and Division: Fewest Significant Figures Rule

The result of multiplication or division must be rounded to contain the same number of significant figures as the measurement with the fewest total significant figures.

Example: Density Determination

A mineral specimen has a mass of 18.42 g18.42\text{ g} (44 sig figs) and a displaced volume of 6.2 mL6.2\text{ mL} (22 sig figs):

ρ=18.42 g6.2 mL=2.9709677… g/mL  ⟹  3.0 g/mL(2 sig figs)\rho = \frac{18.42\text{ g}}{6.2\text{ mL}} = 2.9709677\dots\text{ g/mL} \implies \mathbf{3.0\text{ g/mL}} \quad (2\text{ sig figs})

Tip

Guard Digits in Multi-Step Calculations: When performing multi-step laboratory calculations, carry at least two extra guard digits (or retain all internal calculator digits) through intermediate steps. Round only once at the final step to the correct number of significant figures. Premature rounding can change the final answer.

Significant Figures on Logarithmic Scales (pH and pOH)

The thermodynamic pH is −log⁡10-\log_{10} of hydrogen-ion activity. For the dilute-solution approximation used here, insert the numerical molarity relative to 1 mol/L1\text{ mol/L}. For concentration calculations using base-10 logarithms, match the number of decimal places in pH to the significant figures in the concentration. IUPAC pH definition

Worked Example: Concentration to pH

Calculate the pH\text{pH} of a solution where [H3O+]=3.85×10−4 M[\text{H}_3\text{O}^+] = 3.85 \times 10^{-4}\text{ M} (33 significant figures):

pH=−log⁡(3.85×10−4)=−(−3.414539… )=3.415\text{pH} = -\log(3.85 \times 10^{-4}) = -(-3.414539\dots) = 3.\mathbf{415}

The concentration contains three significant figures, so report 3.4153.415 with three decimal places under the stated approximation.

Worked Example: pH to Concentration

Calculate the [H3O+][\text{H}_3\text{O}^+] for a solution with pH=9.20\text{pH} = 9.20 (22 decimal places):

[H3O+]=10−9.20=6.30957×10−10 M  ⟹  6.3×10−10 M(2 sig figs)[\text{H}_3\text{O}^+] = 10^{-9.20} = 6.30957 \times 10^{-10}\text{ M} \implies \mathbf{6.3 \times 10^{-10}\text{ M}} \quad (2\text{ sig figs})

Test Your Knowledge

On a burette marked every 0.1 mL, the meniscus is about four-fifths of the way down from 24.3 mL to 24.4 mL. The scale and meniscus are clear enough to estimate one additional digit. What reading should be recorded?

A

24.4 mL

B

24.38 mL

C

24.375 mL

D

24.400 mL

Test Your Knowledge

A student determines the density of an irregularly shaped mineral sample. The mass of the mineral is measured on an analytical balance as 14.825 g. The initial volume of water in a graduated cylinder is 22.4 mL, and after completely submerging the insoluble mineral without trapping bubbles, the water level rises to 28.1 mL. What is the calculated density of the mineral sample reported to the correct number of significant figures?

A

2.6009 g/mL

B

2.60 g/mL

C

2.6 g/mL

D

3 g/mL

Test Your Knowledge

A solution of hydrochloric acid is measured to have a hydronium ion concentration of [H₃O⁺] = 4.80 × 10⁻⁴ M. Using the dilute-solution approximation, what is the pH of this solution reported to the correct number of significant figures?

A

3.319

B

3.32

C

3.3

D

3.3188

Sections you finish are checked off in the contents.