14.3 Chemical Safety, Hazard Communication (GHS/SDS), and Storage
Key Takeaways
Keep eyewash and shower routes unobstructed and know the school’s chemical-exposure procedure. OSHA workplace requirements and equipment design guidance have different roles.
Combustible metal fires are Class D. The extinguisher must be rated for the specific metal and used only by trained, authorized responders.
Use SDS Section 2 for hazards, Section 4 for first aid, Section 6 for spills, Sections 7 and 10 for storage and compatibility, and Section 8 for exposure controls.
Store chemicals by compatibility before sorting them alphabetically. Concentrated nitric acid is an oxidizing acid and must be kept away from incompatible materials.
Plan waste collection before starting an activity. Check the school’s procedure for the specific chemical mixture and never use pH alone to determine drain eligibility.
14.3 Chemical Safety, Hazard Communication (GHS/SDS), and Storage
Before a school laboratory activity, identify the chemicals and quantities, choose the smallest suitable scale, review the product Safety Data Sheets (SDSs), and check that the planned controls and emergency equipment are available. Follow the NIOSH school chemistry guidance and the school's procedures. Occupational Safety and Health Administration (OSHA) rules govern covered workplaces. Applicable state and local rules and school policies may also apply.
1. Laboratory Safety Infrastructure and Personal Protective Equipment (PPE)
Ensuring student and instructor safety requires active engineering controls, administrative protocols, and personal protective equipment.
Personal Protective Equipment (PPE)
- Wear chemical-splash goggles for splash hazards. Ordinary prescription glasses are not a substitute. A face shield can supplement goggles for a greater splash risk.
- Choose the lab coat or apron for the task. Wear closed-toe shoes and keep hair and loose clothing away from chemicals and flames.
- Select gloves using the product SDS and a glove manufacturer's chemical-resistance data. Material, thickness, chemical concentration and contact time affect protection. A disposable nitrile glove is not suitable for every solvent.
Emergency Equipment and First Response
| Equipment | What a teacher checks before students start |
|---|---|
| Eyewash | It is accessible immediately, with a clear path and hands-free flow. In an ordinary corrosive liquid eye splash, begin flushing promptly while help is summoned, and follow the chemical-specific first-aid instructions. |
| Safety shower | Keep the route clear and show students how to activate it. The school's response plan and SDS specify the response to body contamination. |
| Fire alarm and exit | Everyone knows how to alert the school and leave safely. Fire extinguishers are for trained and authorized personnel. |
| Chemical fume hood | Verify the airflow indicator and marked operating sash height. Use the hood appropriate to the task and keep the exhaust path clear. |
Where employees could be exposed to injurious corrosive materials, federal workplace rule 29 CFR 1910.151(c) requires suitable facilities for immediate emergency flushing. OSHA points to ANSI/ISEA Z358.1 for equipment design guidance. A typical planning benchmark is an unobstructed route that can be traveled in 10 seconds or less, with placement suited to the hazard. An eyewash conforming to the standard supplies at least 0.4 gallons per minute of tepid flushing fluid for at least 15 minutes; a safety shower has a different design flow, 20 gallons per minute. The equipment rating is separate from the appropriate flushing duration for a particular exposure. OSHA eyewash guidance · ANSI/ISEA equipment guide
Fire Extinguishers and Classification
Know the fuel or energy source before selecting a fire extinguisher. Follow the school emergency action plan, alert others, and evacuate students. Staff may attempt to extinguish a small, developing fire only if authorized and trained and they have a clear escape route.
| Class | Fuel | Example of a suitable rated agent |
|---|---|---|
| A | Ordinary combustibles, such as wood or paper | A-rated water or multipurpose ABC dry chemical |
| B | Flammable liquids or gases | B-rated agent appropriate for the fuel |
| C | Energized electrical equipment | C-rated nonconductive agent |
| D | Combustible metals | Class D agent rated for the specific metal |
| K | Cooking oils and fats | K-rated agent |
For a sodium metal fire, a sodium-rated Class D extinguisher is appropriate. The agent can differ for lithium or other metals. Water can react with burning sodium and release heat and flammable hydrogen. Ordinary water, foam or a carbon dioxide extinguisher is not a substitute for a sodium-rated agent. OSHA fire classes · Example of metal-specific extinguisher ratings
Chemical Fume Hoods
A chemical fume hood controls airborne exposure by drawing air inward and containing contaminants. Keep your head outside the opening. Follow the marked working sash height and airflow range for the installed hood, keep equipment and containers clear of the baffles, and use the designated cabinets for chemical storage. A hood alarm means to stop work safely and follow the school's response procedure. OSHA hood guidance
2. Hazard Communication: GHS and SDS
The Globally Harmonized System of Classification and Labelling of Chemicals (GHS) is an international framework. The U.S. OSHA Hazard Communication Standard adopts its hazard classification and communication principles in covered workplaces. Use the current U.S. label and SDS for the exact product and concentration.
The 16-Section Safety Data Sheet (SDS)
Under 29 CFR 1910.1200 Appendix D, the SDS format includes 16 numbered headings. OSHA requires content for Sections 1–11 and 16. Sections 12–15 cover ecological, disposal, transport and regulatory information, and OSHA does not enforce their content.
16-SECTION SAFETY DATA SHEET (SDS)
┌─── Section 1: Chemical Identification
├──► Section 2: Hazard(s) Identification (GHS pictograms, signal word, hazard statements)
├─── Section 3: Composition / Information on Ingredients (CAS numbers)
├──► Section 4: First-Aid Measures (route-specific response)
├─── Section 5: Fire-Fighting Measures (suitable extinguishing media)
├─── Section 6: Accidental Release Measures (spill containment protocols)
├──► Section 7: Handling and Storage (incompatibilities, ventilation requirements)
├──► Section 8: Exposure Controls / Personal Protection (OSHA PEL, ACGIH TLV, PPE)
├─── Section 9: Physical and Chemical Properties (boiling pt, flash pt, vapor pressure)
└──► Section 10: Stability and Reactivity (incompatible materials, decomposition products)
Sections 11–16: Toxicology, Ecology, Disposal, Transport, Regulation, Other Info
- Signal Words: Where a signal word is assigned, it indicates severity within the hazard classification:
- "DANGER": Indicates more severe hazard categories.
- "WARNING": Indicates less severe hazard categories.
GHS Hazard Pictograms
The official label pictograms are black symbols on white fields with red diamond borders. The recognition cues below summarize their shapes. A product may carry more than one pictogram. Check the accompanying hazard statements and OSHA’s label rules.
| Recognition cue | Pictogram name | Hazards it can indicate |
|---|---|---|
| Flame | Flame | Flammables, pyrophorics, self-heating materials and certain other fire hazards |
| Flame over circle | Flame Over Circle | Oxidizing gases, liquids or solids |
| Liquid attacking metal and hand | Corrosion | Skin corrosion, serious eye damage or corrosivity to metals |
| Bursting object | Exploding Bomb | Explosives and certain self-reactive substances and organic peroxides |
| Skull and bones | Skull and Crossbones | Acute toxicity (fatal or toxic from a specified exposure route) |
| Person with chest star | Health Hazard | Carcinogenicity, mutagenicity, reproductive toxicity, respiratory sensitization, target-organ toxicity or aspiration hazard |
| Exclamation mark | Exclamation Mark | Irritant (skin/eye), skin sensitizer, acute toxicity (harmful), narcotic effects |
| Cylinder | Gas Cylinder | Gases under pressure (compressed, liquefied, dissolved; e.g., tanks) |
| Fish and tree | Environment | Aquatic toxicity (acute and long-term environmental hazards; non-mandatory by OSHA) |
The NFPA 704 Hazard Identification Diamond
The National Fire Protection Association (NFPA) 704 standard uses a color-coded four-quadrant diamond to convey hazards to emergency responders on a scale from (minimal hazard) to (extreme hazard):
NFPA 704 HAZARD DIAMOND
RED
(Flammability)
0 to 4
┌───┐
│ 3 │
┌───┬───┼───┼───┬───┐
BLUE │ 2 │ │ │ │ 0 │ YELLOW
(Health) └───┴───┼───┼───┴───┘ (Instability)
0 to 4 │ W̶ │ 0 to 4
└───┘
WHITE
(Special)
OX, W̶, SA
- Blue: Acute health hazard.
- Red: Flammability.
- Yellow: Instability.
- White: Special hazards. A barred W indicates unusual reactivity with water, OX denotes an oxidizer, and SA identifies designated simple asphyxiant gases.
Use the diamond for emergency hazard identification. Its scale runs from 0 (least severe) to 4 (most severe). The category numbers in the workplace hazard classification serve a different purpose and should not be copied into the diamond. OSHA’s NFPA comparison
3. Chemical Storage Compatibility
Group chemicals by compatibility first, then use an alphabetical order within a compatible group if useful. Check SDS Sections 7 and 10 for the exact product. Use the school's chemical inventory, approved cabinets and compatible secondary containment to prevent leaked products from mixing.
| Group | Example of a stockroom decision |
|---|---|
| Acids and bases | Segregate them to prevent unintended reaction and heat release. |
| Oxidizing acids | Place concentrated nitric acid in its designated separate compartment or storage location, away from incompatible materials including organic acids. |
| Flammable liquids | Use an approved flammable-liquid storage cabinet when called for by school policy and applicable code. Keep flammables away from oxidizers and ignition sources. |
| Water-reactive materials | Keep away from water and incompatible materials. Preserve the supplier's storage conditions for the specific product. |
| Peroxide-forming chemicals | Follow the school's inventory and disposal schedule for the specific reagent. An old or suspect container belongs with trained hazardous-materials personnel. |
If the school finds an old container with unknown contents or suspected instability, secure the area and refer it to designated staff. Avoid opening it to identify the contents. NIOSH school storage guidance
4. Reagent Preparation, Spill Response, and Waste
Safe Preparation and Handling
- Verify the product identity and concentration before dispensing. Prepare only the amount needed and keep unused material out of the original stock bottle.
- For authorized aqueous dilution of a concentrated acid such as sulfuric acid, add acid to water under the approved procedure. Dilution releases heat, and adding water to a small part of concentrated acid can cause hot corrosive splashes. Use the specified protective equipment, ventilation, and temperature controls.
- Mark prepared reagents and secondary containers according to the school's labeling system. Include the product identity, concentration and hazards so another teacher can identify them. For dates, initials and transport containers, use school procedure and the SDS.
Spill Response
Alert the teacher or designated staff and follow the school's incident plan. Consult SDS Section 6 for spill procedures and Section 4 for any exposure. Small identified spills may be handled by trained staff under an applicable procedure. Isolate the area and follow the emergency plan for an unknown material, a significant exposure or a release beyond that procedure.
An acid can react with bicarbonate to form carbon dioxide and water. This reaction explains fizzing where that agent is used. The end of visible bubbling is not a test that a spill is safe. The proper response and cleanup agent depend on the product and circumstances. Never vacuum a mercury spill. Keep students away and follow the school’s mercury response plan. EPA school environmental guidance, May 2026
Waste Segregation and Disposal
| Waste decision | What to do in a school lab |
|---|---|
| Determine the waste type | Identify the contents and hazards at generation. Ask the designated school waste manager how the mixture is classified. |
| Accumulate compatible wastes | Use the designated compatible container. Keep it closed except as needed for authorized handling, label it for its contents and hazards, and separate incompatible materials. Follow the applicable accumulation and pickup procedures. |
| Manage solvents and metal-bearing solutions | Collect them in the streams specified by the school's waste program. Different disposal routes can require separate solvent or metal streams. |
| Decide whether any drain discharge is allowed | Follow the school and wastewater authority's approval for the exact waste. Dilution or an acceptable pH alone does not make a waste eligible for discharge. |
| Dispose of glass | Put clean broken glass in the designated puncture-resistant container. Treat chemically contaminated glass according to the waste program. |
For example, if two classes share a lab and one produces a dilute silver-bearing solution, check the school waste plan and designate the collection container before class. A clear appearance or near-neutral pH gives no assurance that a metal-bearing solution is suitable for the sink. Federal waste determinations and satellite accumulation requirements are in 40 CFR 262.11 and 40 CFR 262.15 where applicable. Generator category, state regulations and local rules affect implementation.
Students have evacuated after a small fire involving metallic sodium. If the school emergency plan permits a trained responder to attempt extinguishment, which extinguisher is suitable for this fuel?
Pressurized water from a Class A fire extinguisher
A Class D dry-powder extinguisher specifically rated for sodium
Carbon dioxide (CO₂) from a Class B/C extinguisher
Aqueous film-forming foam (AFFF)
A chemistry teacher is reorganizing the chemical stockroom. Which of the following storage arrangements violates fundamental chemical safety and compatibility guidelines?
Keeping a water-reactive reagent in its intact supplier container under the storage conditions specified by its Safety Data Sheet.
Keeping concentrated hydrochloric acid segregated from concentrated aqueous ammonia.
Keeping flammable solvents in an approved flammable-liquid storage cabinet, away from oxidizers.
Storing concentrated nitric acid alongside glacial acetic acid to keep all acids in alphabetical order.
Which section of a Safety Data Sheet under the U.S. OSHA Hazard Communication Standard lists applicable exposure limits, engineering controls, and personal protective equipment?
Section 8: Exposure Controls/Personal Protection
Section 2: Hazard(s) Identification
Section 4: First-Aid Measures
Section 10: Stability and Reactivity
Sections you finish are checked off in the contents.