15.4 Chemical Processes: Corrosion, Oxidation & Embrittlement
Key Takeaways
Electrochemical corrosion requires an anode, cathode, electrolyte, and metallic path; galvanic corrosion is severely aggravated when an unfavorable area ratio exists (small anode coupled to a large cathode).
Austenitic stainless steels held between about 425 and 815 °C (as in weld heat-affected zones) sensitize and suffer intergranular attack; L grades such as 304L or stabilized grades such as 321 and 347 prevent it.
Hydrogen embrittlement causes delayed brittle fracture of high-strength steels (roughly above 39 HRC); plated parts are baked promptly after plating to drive out hydrogen.
Corrosion rate from coupon weight loss is with W in mg, A in in² and t in hours; the corrosion allowance equals rate times design life.
15.4 Chemical Processes: Corrosion, Oxidation & Embrittlement
Chemical and electrochemical attack is one of the most common ways machinery deteriorates in service. The blueprint groups these processes under chemical processes: aqueous corrosion, high-temperature oxidation and the embrittlement mechanisms that turn ductile metals brittle. A designer must recognize each mechanism, estimate its rate, and choose materials, coatings or details that prevent it.
Electrochemical Corrosion Mechanics & Prevention
Metallic corrosion is an electrochemical process that oxidizes refined metals back to low-energy mineral compounds.
The Four Essentials of an Electrochemical Corrosion Cell
An electrochemical corrosion cell requires four concurrent components:
- Anode: The metallic site where oxidation occurs, shedding electrons into the metal and dissolving metal ions into the solution ().
- Cathode: The metallic site where reduction occurs, consuming electrons supplied by the anode (e.g., oxygen reduction in neutral water, or hydrogen evolution in acids).
- Electrolyte: An electrically conductive liquid (e.g., moisture, saltwater, soil) that conducts current via ionic transport.
- Metallic Path: Direct electrical connection transferring electrons from the anode to the cathode.
Caution
Removing any one of these four elements stops that electrochemical cell. Coatings eliminate the electrolyte; insulating bushings break the metallic path; cathodic protection turns the entire structure into a cathode.
Galvanic Corrosion & The Critical Area Ratio Effect
When two electrochemically dissimilar metals are in electrical contact within an electrolyte, a galvanic cell develops. The more active (anodic) metal corrodes preferentially, while the more noble (cathodic) metal is protected.
- The Area Ratio Rule: The rate of galvanic penetration at the anode depends directly on the cathode-to-anode surface area ratio:
- Dangerous Configuration: A small anode coupled to a large cathode (e.g., carbon steel rivets fastening large stainless steel plates). The large cathode draws massive total reduction current, forcing extreme localized current density onto the small anode, causing rapid perforation.
- Acceptable Configuration: A large anode coupled to a small cathode (e.g., stainless steel fasteners joining large carbon steel structural beams).
Specific Corrosion Morphologies
- Pitting Corrosion: Autocatalytic localized attack where passive oxide films (e.g., on 304/316 stainless steel) break down in chloride () environments. The pit interior becomes an anode; restricted fluid exchange hydrolyzes metal ions, creating concentrated hydrochloric acid inside the pit.
- Crevice Corrosion: Localized attack in stagnant micro-gaps beneath gaskets, washers, or overlapping joints. Oxygen is depleted within the crevice, establishing a differential aeration cell where the oxygen-starved crevice becomes anodic relative to the oxygenated exterior surface.
- Stress Corrosion Cracking (SCC):
- Requires the simultaneous presence of three conditions: (1) a susceptible alloy, (2) a sustained tensile stress (applied or residual), and (3) a specific aggressive chemical environment.
- Classical pairs: Austenitic stainless steels in hot aqueous chlorides (); Brass in ammonia ("season cracking"); High-strength carbon steels in hydrogen sulfide (, sulfide stress cracking).
Corrosion Mitigation Strategies
- Cathodic Protection (CP):
- Sacrificial Anode (Galvanic CP): Electrically bonding a sacrificial active metal (zinc, aluminum, magnesium) to the protected structure (underground pipeline, ship hull, water heater tank). The sacrificial metal corrodes, continuously supplying protective electrons.
- Impressed Current Cathodic Protection (ICCP): Uses an external DC power supply connected between an inert anode (mixed metal oxide) and the structure, driving electrons into the structure.
- Protective Coatings & Anodizing:
- Barrier Coatings: Epoxy, polyurethane, and powder paints isolate metal from electrolytes.
- Galvanizing: Hot-dip zinc coating on steel provides both a physical barrier and sacrificial cathodic protection at exposed scratches.
- Anodizing: An electrochemical process that thickens the natural aluminum oxide () passive layer, which is then sealed in hot deionized water or nickel acetate.
Intergranular Corrosion, Dezincification & Erosion-Corrosion
- Sensitization of austenitic stainless steels: holding 300-series steels between about and ( to ), as in a weld heat-affected zone, precipitates chromium carbides on grain boundaries. The chromium-depleted zones next to them corrode preferentially ("weld decay"). Remedies: low-carbon L grades ( C, such as 304L), titanium- or niobium-stabilized grades (321, 347), or solution annealing after welding.
- Dezincification selectively removes zinc from brasses with high zinc content in some waters, leaving weak, porous copper; inhibited or low-zinc alloys avoid it.
- Erosion-corrosion occurs where high-velocity or turbulent flow strips protective films (pump impellers, elbows, heat-exchanger tube inlets). Fretting corrosion is wear plus oxidation at clamped joints that slip microscopically (Section 6.1).
High-Temperature Oxidation
Above a few hundred degrees Celsius, metals react directly with oxygen to form scale. The Pilling-Bedworth ratio (oxide volume per metal volume consumed) indicates whether the scale protects: ratios between about 1 and 2 usually give an adherent, protective film (aluminum is about 1.3), ratios below 1 (magnesium, about 0.8) give porous scale, and much larger ratios build compressive stress that cracks and spalls the scale. When a protective scale controls the rate by diffusion, growth follows the parabolic law , so doubling the exposure time increases scale thickness by only about . Chromium (at least about for stainless steels), aluminum and silicon are added to form protective , or scales.
Embrittlement Mechanisms
- Hydrogen embrittlement: atomic hydrogen from acid pickling, electroplating, welding with damp consumables, cathodic overprotection or sour () service diffuses into steel and causes delayed brittle fracture under sustained tensile stress, often hours or days after assembly. High-strength steels (roughly above 39 HRC) are most susceptible. Plated high-strength parts are baked promptly after plating (typically around to for several hours), and hot-dip galvanizing of the highest-strength structural bolts (such as ASTM A490) is prohibited.
- Caustic embrittlement: concentrated sodium hydroxide at boiler seams and crevices causes intergranular cracking of stressed steel.
- Liquid metal embrittlement: certain liquid metals wet and penetrate grain boundaries, for example zinc on high-strength steel during welding of galvanized parts, or mercury on aluminum and brass.
- Temper embrittlement: alloy steels held or slowly cooled between about and allow impurities (P, Sb, Sn, As) to segregate to grain boundaries, raising the ductile-to-brittle transition temperature.
Corrosion Rate and Corrosion Allowance
A weight-loss coupon test converts directly to a penetration rate:
where mpy is mils (thousandths of an inch) per year. The design corrosion allowance is the expected rate times the design life, added to the pressure or structural thickness (as in the ASME vessel and piping examples of Section 11.1).
Worked example: A carbon steel coupon () with exposed area loses in of service-water exposure.
For a 20-year design life, the corrosion allowance is (about ), so a () allowance would be marginal and is a sensible choice.
A structural engineer is inspecting an offshore steel platform deck where marine atmosphere corrosion is severe. A technician proposes using ASTM A36 carbon steel bolts to fasten heavy 316 stainless steel mounting brackets. How does electrochemical corrosion theory evaluate this joint design?
The joint is safe because 316 stainless steel forms a passive chromium oxide film that completely prevents electron transfer to the carbon steel bolts.
The joint is safe because carbon steel and stainless steel share iron as their primary constituent, eliminating galvanic differences.
The joint is hazardous: the small carbon steel bolts become anodes to the large stainless cathode and corrode rapidly.
The joint is hazardous because the stainless steel plates will rapidly dissolve, leaving the carbon steel bolts unsupported.
A steel corrosion coupon () with of exposed area loses during a test. Using , what is the corrosion rate?
About
About
About
About
Zinc-electroplated alloy steel cap screws hardened to 45 HRC crack in service a few hours after they are tightened, with no overload. What is the most likely mechanism, and how is it prevented?
Temper embrittlement caused by the warm plating bath; prevent it by quenching the screws in oil immediately after plating
Hydrogen embrittlement from plating; bake the parts promptly after plating, or use lower-hardness parts or a non-electrolytic coating
Galvanic corrosion between the zinc coating and the steel; prevent it by stripping the zinc and painting the screws with an epoxy primer instead
Fatigue caused by torque wrench vibration during tightening; prevent it by tightening the screws to a much lower preload