4.2 Microbiology, Immunity & Sterilization Methods
Key Takeaways
The Gram stain separates bacteria by their different cell-envelope staining characteristics. A stain can orient the work-up, and clinical specimens still require test-specific interpretation.
Active immunity follows the patient's own immune response. Passive immunity transfers preformed antibodies and supplies temporary protection.
Critical devices require sterilization. Semicritical devices require at least high-level disinfection. Clean equipment before the selected process.
Match the sterilization cycle, disinfectant contact conditions and monitoring to the device, load, process and manufacturer instructions.
Collect and label appropriate specimens aseptically. In suspected adult sepsis, collect blood cultures promptly, ideally before antibiotics, without a harmful delay in treatment.
Microorganisms and host defenses
Gram-positive bacteria retain the primary Gram stain and appear purple. Gram-negative bacteria have a thinner peptidoglycan layer and an outer membrane and take up the contrasting stain. Knowing the grouping helps interpret a preliminary laboratory report. Mycobacteria have lipid-rich cell envelopes associated with acid-fast staining. In suspected tuberculosis, use the current diagnostic pathway, including molecular testing where indicated. Bacterial endospores resist many low-level disinfection processes, an important reason why a reusable critical item needs a validated sterilization cycle.
Innate immunity includes physical barriers such as skin and early responses such as phagocytosis. Adaptive immunity includes antigen-specific B and T lymphocytes and provides immunological memory. After effective vaccination, the recipient generates an active immune response. Passive immunity uses preformed antibodies, including antibodies transferred across the placenta or given as an immunoglobulin product. Passive protection begins promptly and wanes as the transferred antibodies are cleared.
| Hypersensitivity | Mechanism | Example |
|---|---|---|
| Type I | IgE-associated mast cell activation | Immediate allergic reaction after an allergen exposure in a sensitized patient |
| Type II | Antibody directed against a cell surface or tissue antigen | Acute hemolysis from an ABO-incompatible red cell transfusion |
| Type III | Immune complex deposition and inflammation | Serum sickness |
| Type IV | Delayed, T-cell-mediated inflammation | Induration on a tuberculin skin test, or allergic contact dermatitis to nickel |
Match the specimen to the clinical question
Bacteria are cells, whereas viruses need living host cells to replicate. Fungi are eukaryotes and include yeasts and moulds. A test designed to find one group cannot stand in for a test for another group. For example, a respiratory virus assay detects its specified targets and does not exclude bacterial pneumonia. In a patient receiving antibiotics, a negative bacterial culture needs interpretation in light of when and where the sample was obtained.
The laboratory may report an organism from a colonized site even when it is causing no tissue infection. A contaminated specimen can also yield an organism the patient never had at the sampled site. Communicate the specimen source, signs of illness and previous antimicrobials. An infection-control decision may use transmission risk and the clinical syndrome while diagnostic testing is still pending.
Choose reprocessing from intended use
| Device use | Minimum process after cleaning | Example |
|---|---|---|
| Critical, entering sterile tissue or the vascular system | Sterilization | Reusable surgical instrument |
| Semicritical, contacting mucosa or nonintact skin | High-level disinfection, or sterilization when indicated and compatible | Reusable flexible bronchoscope |
| Noncritical, contacting intact skin | Clean and disinfect according to risk, product label and policy | Reusable blood pressure cuff |
Cleaning removes soil and organic matter that can interfere with later processing. For flexible endoscopes, follow the device instructions for leak testing and complete cleaning. The validated process must contact internal channels as well as exterior surfaces. Follow the disinfectant's labeled concentration, temperature and contact time, then the device instructions for rinsing, drying and storage. A time remembered for one glutaraldehyde product cannot be transferred to a different product or machine.
Steam is preferred for compatible heat- and moisture-stable instruments. As examples for wrapped supplies, the CDC recognizes exposure for 30 minutes at 121°C in a gravity-displacement sterilizer or for 4 minutes at 132°C in a prevacuum sterilizer. These are exposure times for the specified cycles. Select the validated cycle for the actual device, sterilizer, wrapping and load. A compatible low-temperature process may be needed for heat- or moisture-sensitive critical devices. Ethylene oxide processing requires adequate aeration under the validated instructions.
Use mechanical records for time, temperature and pressure, chemical indicators for exposure at their location, and biological indicators to challenge the process with resistant spores. Steam biological indicators use Geobacillus stearothermophilus. A colour change on external tape distinguishes a processed package from one that has not gone through a cycle. Release decisions also depend on the applicable load monitoring and department procedure. Follow the sterile services procedure when a cycle indicator fails.
Collect a specimen the lab can interpret
- Blood cultures in adults. Use adequate volume and aseptic technique. Two sets from separate peripheral sites are commonly obtained in the initial investigation. In suspected sepsis, collect as soon as possible, ideally before antimicrobial administration. Escalate and avoid a harmful treatment delay if collection is difficult.
- Urine for culture. For a patient who can void independently, collect a clean-catch midstream sample in a sterile container. Send promptly and use the lab's specified preservation or transport conditions if delayed. Label the specimen source because results depend on collection method and clinical context.
- Sputum for suspected pulmonary TB. Coach the patient to bring up material from a deep cough, collect in the designated setting with appropriate respiratory precautions, and use the NTEP pathway for specimen number, transport and testing. Saliva alone is a poor substitute for a lower respiratory specimen.
Worked case. A ward sends a reusable flexible bronchoscope and metal instruments from sterile tissue to the same reprocessing unit. The bronchoscope uses its validated scope-specific process, with high-level disinfection as the minimum for routine mucosal contact. The compatible metal instruments require sterilization. Both start with thorough cleaning.
A cleaned reusable flexible bronchoscope will be used for routine mucosal contact. A compatible liquid high-level disinfectant is available. Which action is appropriate?
Use 20 minutes for every glutaraldehyde product and store the scope while wet.
Wipe the exterior with alcohol and skip the channels.
Follow the validated device and disinfectant instructions for channel contact, concentration, temperature, exposure, rinsing and drying.
Use the same steam cycle as metal forceps irrespective of the scope's heat limits.
Which organism's spores are used in a biological indicator designed to monitor steam sterilization?
Geobacillus stearothermophilus
Bacillus atrophaeus
Staphylococcus aureus
Escherichia coli
Firm induration is measured 48 hours after placement of a tuberculin skin test. Which hypersensitivity mechanism produces this delayed induration?
Type I mast cell activation
Type II cell-directed antibody response
Type III immune complex deposition
Type IV T-cell-mediated inflammation
An adult with suspected urosepsis has blood cultures and empiric antimicrobial treatment ordered. Cultures can be collected promptly. What is the best plan?
Wait for the urine culture report before taking blood cultures or starting treatment.
Obtain aseptic blood culture sets promptly, ideally before the first antibiotic dose, and send a properly collected urine specimen without delaying treatment.
Draw both sets through an existing line simply to save time and routinely postpone antibiotics.
Start treatment, then wait until the next fever spike to collect any specimens.
Sections you finish are checked off in the contents.