9.1 Sprayers, Spreaders & Nozzle Selection
Key Takeaways
Choose equipment by application pattern, treatment site and the exact label.
Use the nozzle chart to set broadcast overlap or to apply an even band.
At the same nozzle and with the same liquid, flow is approximately proportional to the square root of pressure.
Measure nozzle output and compare it with the rated output at the test pressure.
Select strainers according to equipment and product directions.
Sprayers, Spreaders & Nozzle Selection
Quick answer. Match the pattern and output to the target and directions for use. Check the manufacturer’s height, pressure, droplet and strainer recommendations. Test the equipment before treating.
Choose the equipment
| Equipment | Useful when | What to check |
|---|---|---|
| Hydraulic boom sprayer | Applying a uniform broadcast spray to a large turf area. | Matched tips, correct spacing and height above target, measured ground speed, stable pressure and appropriate tank agitation. |
| Handgun sprayer | Directing spray at labeled turf or ornamental targets. | The pattern at the working distance, a repeatable sweeping motion and a consistent travel rate for an area treatment. Check drift and runoff around each target. |
| Backpack or hand sprayer | Treating a measured small area or a labeled spot with controlled placement. | Stable pressure, nozzle height, consistent walking speed for area treatments and a calibrated pattern. A regulator can help maintain pressure within its operating range. |
| Rotary spreader | Treating open turf with a dry product whose label permits spreading. | Measure effective swath for the actual granules. Check for even left-to-right distribution and set pass spacing from the measured effective width. |
| Drop spreader | Placing dry material in a narrow strip with limited lateral throw. | Check dispensing width. Use aligned passes for uniform coverage and comply with label restrictions near pavement or water. |
Rotary spreaders develop patterns that vary with granule properties, equipment and operating speed. A gate setting on a package is a starting point for the matching spreader. Verify application rate by measuring output over a known area. An edge shield can change the distribution pattern and cannot replace a required setback. A drop spreader limits lateral throw but misplaced material can still wash off impervious surfaces.
Select the nozzle and confirm its pattern
- A tapered flat-fan has lighter output at the edges. Proper overlap between adjacent fans provides more uniform broadcast coverage. Use the nozzle manufacturer’s chart for the tip, spacing, spray angle and working height. No one percentage applies to every design.
- An even flat-fan distributes a band across its width. A tip designed to apply a single even band delivers excess material where adjacent bands cover the same ground. For example, the TeeJet AI Even is an air-induction design for banding without overlap. Air induction by itself does not determine the pattern.
- A hollow-cone tip distributes spray in a ring. It can be used for coverage on ornamental foliage when the label and droplet requirements permit. Check the selected model’s output and droplet classification. Fine droplets can drift and a ring pattern does not guarantee underside coverage.
- Flooding nozzles can provide a wide fan, and solid-stream tips direct liquid to a narrow target. Choose pressure and placement from the specific nozzle and use directions. Coarser droplets may reduce drift, but applicable droplet, wind and setback limits still govern.
Use pressure changes for small corrections
For the same hydraulic tip and liquid, the flow ratio is approximately:
If a tip delivers 0.20 GPM at 20 PSI, doubling its flow mathematically takes 80 PSI since the flow ratio squared is 4. That result does not establish a permissible pressure. For a given tip, higher pressure usually produces smaller droplets. Check its droplet chart and the label before changing pressure. If a large output change is needed, choose an appropriate tip and recalibrate. Reducing travel speed can increase the gallons applied per unit area at the same nozzle flow. Slowing down does not increase the nozzle’s GPM.
Look for wear, clogging and poor distribution
Collect water from each matching tip over the same period and compare it with the manufacturer’s rated output at the measured tip pressure. TeeJet considers its tips excessively worn when output is more than 10% above that of a new matching tip. A low reading can reflect a plugged strainer, a plumbing restriction or a different pressure at the tip. Compare individual performance and verify the pattern. A whole set may be worn even when output is similar across the boom. Shut down and relieve pressure before servicing, wear the required PPE and clean tips with the recommended brush rather than metal wire.
A higher mesh count generally corresponds to finer openings for comparable screens. Choose the strainer specified for the nozzle, equipment and formulation. For example, TeeJet specifies 100 mesh for the XR110015VP and 50 mesh for other larger XR sizes in its polymer tip chart. An unnecessarily fine screen can restrict flow. If a product and the equipment have incompatible requirements, select a compatible setup before proceeding.
Sources
- UF/IFAS spreader calibration and measured swath
- TeeJet technical catalog, nozzle wear, pattern and droplet data
- TeeJet XR polymer extended range flat spray tip chart
- TeeJet AI Even manufacturer's product specifications
- EPA National Pesticide Applicator Certification Core Manual, application equipment chapter
At the same hydraulic spray tip and with the same liquid, what pressure change would theoretically double output in GPM?
Increase pressure to four times the original value.
Increase pressure to twice the original value.
Increase pressure to one and a half times the original value.
Halve the pressure and raise the boom.
Which pattern is designed to provide uniform coverage across a single band without overlap?
Tapered flat-fan broadcast pattern
Hollow-cone pattern
Even flat-fan banding pattern
Solid-stream pattern
A TeeJet tip is rated for 0.40 GPM at the test pressure with water. After confirming the liquid, tip model and pressure, the technician repeatedly measures 0.46 GPM. What should the technician do?
Lower boom pressure until the suspect tip reads 0.40 GPM.
Install a finer screen only at that nozzle to reduce output.
Use copper wire to return the opening to the original size.
Replace the excessive-output tip with a matching new tip and retest.
Sections you finish are checked off in the contents.