9.3 Aircraft Wire Selection (MIL-W-5086 / MIL-W-22759), Sizing & Bundling
Key Takeaways
- Aircraft wiring strictly utilizes stranded conductors (minimum 19 strands) for vibration fatigue resistance; aluminum conductor wire is restricted to large power feeder lines of AWG 8 and larger with specialized anti-oxidation terminations.
- Military specifications govern aircraft wire insulation: legacy MIL-W-5086 uses PVC/nylon, while modern high-performance MIL-W-22759 (SAE AS22759) uses cross-linked fluoropolymers (Tefzel/PTFE) rated for temperatures up to 150°C–260°C with exceptional arc-tracking resistance.
- American Wire Gauge (AWG) numbers are inversely related to conductor diameter; cross-sectional area is measured in Circular Mils ($A = d^2$), where 1 mil = 0.001 inch.
- Allowable voltage drop limits per AC 43.13-1B dictate a maximum of 1.0 V drop for continuous 28 VDC circuits (2.0 V intermittent) and 0.5 V drop for continuous 14 VDC circuits.
- Wire bundling standards mandate clamp deflection of 1/2" to 3/4" between clamps, drip loops before connectors, routing electrical bundles strictly ABOVE fluid lines with a minimum 3/8" clearance, and a maximum of 4 terminal lugs per stud post.
9.3 Aircraft Wire Selection (MIL-W-5086 / MIL-W-22759), Sizing & Bundling
FAA Airframe Subject Matter Focus: Proper wire selection, sizing, routing, clamping, and termination are critical to airworthiness and flight safety. Technicians must master conductor metallurgy (stranded copper plating types vs aluminum limitations), insulation specifications (MIL-W-5086 vs MIL-W-22759 Tefzel), American Wire Gauge (AWG) circular mil calculations, allowable voltage drop limits per AC 43.13-1B, bundle thermal derating, MS21919 cushion clamp spacing, drip loop construction, fluid line clearance rules, calibrated full-cycle ratchet crimping standards, and terminal stud stacking rules.
1. Aircraft Wire Metallurgy & Military Specifications
Aircraft electrical systems operate in extreme operational environments characterized by severe vibration, high-G loads, wide temperature swings ($-55^\circ\text{C}$ to $+200^\circ\text{C}$), low atmospheric pressures, and exposure to aggressive fluids (Skydrol hydraulic fluid, aviation fuels, turbine oils, deicing fluids).
AIRCRAFT STRANDED CONDUCTOR METALLURGY
┌──────────────────────────────────────────────┐
│ Outer Insulation Jacket (Tefzel / PTFE) │
│ ┌────────────────────────────────────────┐ │
│ │ Conductor: Minimum 19 Strands │ │
│ │ of Plated High-Purity Copper │ │
│ │ (Tin, Silver, or Nickel Plated) │ │
│ └────────────────────────────────────────┘ │
└──────────────────────────────────────────────┘
Conductor Metallurgy: Copper vs. Aluminum
- Stranded Copper Conductors: Aircraft wiring strictly prohibits solid single-strand conductors for airframe wiring (except for specialized high-temperature thermocouples and rigid bus bars). All aircraft wire uses flexible stranded conductors (minimum 19 strands for small gauges, up to several hundred strands for large feeder cables) to eliminate vibration fatigue hardening and wire breakage.
- Tin-Coated Copper: Rated for service temperatures up to $150^\circ\text{C}$ ($302^\circ\text{F}$). Economical general airframe use.
- Silver-Coated Copper: Rated for service temperatures up to $200^\circ\text{C}$ ($392^\circ\text{F}$). Excellent high-frequency conductivity (skin effect).
- Nickel-Coated Copper: Rated for service temperatures up to $260^\circ\text{C}$ ($500^\circ\text{F}$). Required in engine nacelles, fire zones, and exhaust areas.
- Aluminum Conductors (Weight Reduction vs. Strict Limitations):
- Aluminum wire possesses approximately 61% of the electrical conductivity of copper but only 30% of its weight, making it attractive for large power feeder cables.
- CRITICAL FAA RULE: Aluminum conductor wire is permitted ONLY in large gauge sizes: AWG 8 and larger.
- Aluminum wire is strictly prohibited in sizes smaller than AWG 8 (e.g., AWG 10, 12, 14, etc.) because small aluminum strands are extremely brittle, highly susceptible to notch failure during stripping, subject to progressive cold-flow / creep under terminal screws, and develop non-conductive aluminum oxide films that cause high-resistance terminal fires.
- Installation Requirements for Aluminum Wire: Must use specialized aluminum-rated terminal lugs (MS25439 / MS25440), coated with an approved petroleum-zinc dust anti-oxidation compound (e.g., Alnox / Penetrox) to exclude air and moisture.
2. Wire Insulation Standards: MIL-W-5086 vs. MIL-W-22759
WIRE INSULATION LAYER COMPARISON
MIL-W-5086 (Legacy Standard) MIL-W-22759 (Modern Tefzel/PTFE)
┌──────────────────────────────┐ ┌──────────────────────────────┐
│ Clear Nylon Outer Jacket │ │ Single or Dual Extrusion │
├──────────────────────────────┤ │ Cross-Linked ETFE (Tefzel) │
│ PVC (Polyvinyl Chloride) │ │ or Fluoropolymer PTFE │
├──────────────────────────────┤ ├──────────────────────────────┤
│ Stranded Copper Conductor │ │ Stranded Plated Copper │
└──────────────────────────────┘ └──────────────────────────────┘
Max Temp: 105°C - 125°C Max Temp: 150°C - 260°C
Hazard: Toxic HCl Smoke / Arc Track High Abrasion / Chemical Resistant
Insulation Specifications Breakdown
| Specification | Commercial / Material Trade Name | Temperature Rating | Key Maintenance & Airworthiness Characteristics |
|---|---|---|---|
| MIL-W-5086 | PVC / Nylon (Polyvinyl Chloride core with extruded outer Nylon jacket) | $105^\circ\text{C}$ to $125^\circ\text{C}$ | • Legacy standard on older aircraft.<br>• Severe Hazards: Under electrical fire conditions, PVC decomposes to release thick black toxic smoke and corrosive Hydrogen Chloride ($HCl$) gas which forms hydrochloric acid in moisture.<br>• Highly susceptible to "wet arc tracking" (carbon arc fires). |
| MIL-W-22759<br>(SAE AS22759) | Tefzel (ETFE) / PTFE (Teflon) / FEP (Fluoropolymers) | $150^\circ\text{C}$ to $260^\circ\text{C}$ | • Modern aerospace benchmark.<br>• Exceptional resistance to Skydrol hydraulic fluid, aviation fuels, solvents, and battery acid.<br>• Non-flammable, self-extinguishing, produces minimal non-toxic smoke.<br>• Superior cut-through resistance, lightweight thin-wall insulation, zero wet-arc tracking propagation. |
| MIL-W-81381 | Kapton (Polyimide film tape) | $200^\circ\text{C}$ | • Extremely lightweight and thin wall.<br>• Airworthiness Warning: Highly susceptible to hydrolysis degradation in humid environments and catastrophic dry/wet electrical arc tracking (a spark carbonizes the tape, creating an explosive conductive plasma fire that destroys entire wire harnesses). Largely superseded by AS22759. |
3. American Wire Gauge (AWG) Sizing & Sizing Calculations
In the American Wire Gauge (AWG) system, conductor sizes are designated by numerical gauge numbers. The AWG scale is inversely proportional to conductor size: a smaller gauge number designates a larger diameter, lower resistance, and higher current capacity.
Circular Mil (CM) Area Calculation
In aviation electrical engineering, the cross-sectional area of a circular conductor is measured in Circular Mils (CM) rather than square inches:
Where $d$ is the solid conductor diameter expressed in mils. For example, a wire conductor with a diameter of $0.064\text{ inches} = 64\text{ mils}$ has a cross-sectional area of:
Resistance and Voltage Drop Determination
Conductor electrical resistance ($R$) and resultant voltage drop ($\Delta V$) are calculated using the conductor length ($L$ in feet), circular mil area ($A$), and resistivity ($\rho$, where $\rho \approx 10.4\text{ to }10.8 \ \Omega\cdot\text{CM/ft}$ for annealed copper at $20^\circ\text{C}$):
Maximum Allowable Voltage Drop (AC 43.13-1B Table 11-1)
To ensure proper equipment operation, the voltage drop between the primary power bus bar and the terminal connections of the connected electrical appliance must never exceed the limits mandated in AC 43.13-1B:
| Nominal Electrical System Voltage | Continuous Operation (Max Allowable $\Delta V$) | Intermittent Operation (Max Allowable $\Delta V$) |
|---|---|---|
| 28 VDC | 1.00 Volt (Bus = 28.0V $\rightarrow$ Load $\ge$ 27.0V) | 2.00 Volts (Bus = 28.0V $\rightarrow$ Load $\ge$ 26.0V) |
| 14 VDC | 0.50 Volt (Bus = 14.0V $\rightarrow$ Load $\ge$ 13.5V) | 1.00 Volt (Bus = 14.0V $\rightarrow$ Load $\ge$ 13.0V) |
| 115 VAC 400 Hz (Phase-to-Neutral) | 4.00 Volts | 8.00 Volts |
| 200 VAC 400 Hz (Phase-to-Phase) | 7.00 Volts | 14.00 Volts |
WIRE SIZING SELECTION PROCEDURE (AC 43.13-1B)
Step 1: Identify System Voltage & Operating Mode (Continuous vs Intermittent)
│
▼
Step 2: Determine Maximum Amperage (I) & One-Way Wire Run Length (L in feet)
│
▼
Step 3: Consult AC 43.13-1B Wire Sizing Chart (Chart 11-2 / 11-3)
Find intersection of Current (Amps) and Wire Length (Feet)
│
▼
Step 4: Compare against Mechanical Strength Minimum (AWG 22 for single wire /
AWG 24 in supported bundles; AWG 20 for unjacketed single runs)
│
▼
Step 5: Apply Bundle & Altitude Thermal Derating Factors -> Select Final AWG
Bundle Thermal Derating & Ambient Temperature Limits
When multiple wires are grouped into a bundle or enclosed conduit, heat generated by $I^2 R$ losses cannot dissipate into free air. AC 43.13-1B mandates bundle derating:
- In a bundle carrying 30 or more loaded wires, each individual wire's continuous current-carrying ampacity must be derated to approximately 40% to 50% of its single-wire free-air rating.
- Altitude Derating: At high flight levels ($>40,000\text{ ft}$), the lower density of ambient air significantly reduces convective cooling, requiring further current derating to prevent conductor temperature exceeding insulation ratings.
4. Wire Bundling, Routing & Clamping per AC 43.13-1B
Proper mechanical installation of aircraft wire bundles prevents chafing, vibration fatigue, strain on connector pins, and fluid contamination.
MS21919 CUSHION CLAMP & DRIP LOOP
Bulkhead or Connector
Wire Bundle MS21919 Clamp ┌──────────────┐
───────────────────┐ ┌─────────────┐ │ │
│ │ [Cushion] │ │ │
└────────┤ (●) Bolt ├─────────┼──> (Box) │
└─────────────┘ │ │ │
│ │ │
Max Deflection between clamps: │ │ │
1/2" to 3/4" ▼ └──────────────┘
[DRIP LOOP]
(Moisture drips off here,
preventing water from
entering connector)
Critical Wire Bundling & Routing Rules
- Clamping Spacing & Bundle Slack/Deflection:
- Wire bundles must be supported by MS21919 cushion clamps spaced at intervals of no more than 24 inches (and closer in high-vibration zones).
- Bundle Deflection: When pushed with moderate finger pressure midway between clamps, the bundle must deflect between $1/2\text{ inch}$ and $3/4\text{ inch}$ (13 to 19 mm).
- Never pull a bundle taut like a guitar string: Lack of slack transmits airframe flexural strain directly into connector pins and terminal studs, pulling crimps apart.
- Excessive slack ($>3/4\text{ in}$) causes the bundle to sag and chafe against sharp structural stringers, frames, and control cables.
- MS21919 Cushion Clamp Selection:
- Neoprene / Nitrile Rubber Cushions: Standard general airframe bays.
- PTFE (Teflon) / Fluorosilicone Cushions (Color-coded yellow or blue stripe): Mandatory in engine nacelles, wheel wells, fuel tank dry bays, and areas exposed to phosphate-ester hydraulic fluids (Skydrol) or high temperatures.
- Clamp Installation: Clamp bolt must be mounted horizontally or above the bundle so that if the retaining nut loosens, the bolt cannot drop into the bundle.
- Separation from Plumbing & Combustible Fluid Lines:
- ABOVE FLUID LINES MANDATE: Electrical wire bundles must ALWAYS be routed ABOVE fluid lines (fuel, hydraulic fluid, engine oil, alcohol, battery drain lines).
- NEVER route wiring BELOW a fluid line: If a plumbing B-nut or fitting leaks, dripping combustible fluid will pool on the wire harness and ignite upon the slightest electrical spark.
- Minimum Physical Clearance: A minimum physical separation of $1/2\text{ inch}$ ($0.5\text{ in}$) must be maintained between wire bundles and fluid lines. If rigidly clamped to common structure, absolute minimum separation is $3/8\text{ inch}$ ($0.375\text{ in}$). If separation is impossible, a continuous mechanical barrier or conduit must isolate the wiring.
- Control Cable Clearance: Maintain a minimum of $1/2\text{ inch}$ clearance from all moving flight control cables and push-pull rods under all dynamic deflection states.
- Drip Loops:
- A drip loop (a localized downward bend in the harness) must be formed immediately prior to wire bundle termination at a bulkhead feed-through, junction box, or multi-pin electrical connector.
- Condensation and fluids running along the harness flow down to the bottom of the loop and harmlessly drip off, preventing moisture from pooling inside connector grommets and corroding electrical pins.
- Minimum Bend Radii (AC 43.13-1B Section 11-96):
- Standard Wire Bundles: Minimum bend radius is $6 \times$ the outer diameter ($6D$) of the bundle.
- Sharply Bent Individual Wires (at break-outs): Minimum bend radius is $3 \times$ outer diameter ($3D$).
- Coaxial Cables (RF / Antenna): Minimum bend radius is $6 \times\text{ to }10 \times$ cable outer diameter ($10D$) to prevent crushing the internal foam dielectric, which alters cable characteristic impedance ($50\ \Omega$) and produces high Standing Wave Ratios (VSWR).
5. Stripping, Crimping, Terminals & Connector Assembly
PROPER TERMINAL STUD ASSEMBLY (MAX 4 LUGS)
[ Locking Nut / Plain Nut ]
│
[ Lock Washer ]
│
[ Flat Washer ]
│
┌───────────────────┴───────────────────┐
│ Terminal Lug 4 (Top) │
├───────────────────────────────────────┤
│ Terminal Lug 3 (Interlocked 180°) │
├───────────────────────────────────────┤
│ Terminal Lug 2 │
├───────────────────────────────────────┤
│ Terminal Lug 1 (Largest - Bottom) │
└───────────────────┬───────────────────┘
│
[ Terminal Stud Post ]
Precision Wire Stripping & Full-Cycle Ratchet Crimping
- Precision Wire Stripping: Stripping must be accomplished using calibrated thermal wire strippers or mechanical strippers with precision-ground die blades sized exactly to the wire gauge. Hand knife stripping is strictly prohibited.
- Conductor Damage Limits: Zero nicked, scraped, severed, or missing strands are permitted on fine-gauge wires (AWG 16 to 24). Cutting even 2 or 3 strands on an AWG 22 wire reduces mechanical tensile strength by 15% to 20% and creates an electrical localized hot spot.
- Crimping vs. Soldering: Modern aviation practices exclusively mandate compression crimping for aircraft wire terminations. Soldering creates a stiff, rigid boundary at the edge of the solder wick (flux embrittlement), which rapidly fractures under normal airframe acoustic and engine vibration.
- Calibrated Full-Cycle Ratchet Crimping Tools (MIL-DTL-22520):
- Aviation terminal crimpers utilize an internal ratchet mechanism that will NOT release the terminal lug until the crimping jaws have reached 100% full compression stroke.
- Technicians must never use cheap automotive non-ratchet crimp pliers.
- Pull-Test Calibration: Crimp integrity is verified through periodic destructive and non-destructive tensile pull tests (e.g., minimum pullout force: AWG 22 = 8 lbs, AWG 20 = 19 lbs, AWG 16 = 50 lbs, AWG 10 = 80 lbs per AC 43.13-1B Table 11-19).
Terminal Lugs & Stud Stacking Limits
- Ring-Tongue Terminals (MS25036 Insulated / MS20659 Uninsulated): Must be used on all aircraft stud connections. Slotted fork (spade) terminals are strictly prohibited in aircraft electrical circuits because if the retaining nut loosens slightly, the spade will slip completely off the stud, causing catastrophic open circuits or dead shorts.
- Maximum Lugs per Stud Post: Under AC 43.13-1B Section 11-161, a maximum of four (4) terminal lugs may be stacked on any single electrical junction stud or bus bar post.
- Stacking Sequence:
- The terminal lug carrying the highest current (largest physical gauge/tongue) is installed at the bottom against the bus bar contact surface.
- Successive lugs are stacked in descending order of size.
- Terminal tangs must be positioned so that they cannot rotate into adjacent posts, nesting flat back-to-back or flared at $180^\circ$ or $90^\circ$ angles.
- Stacking order above the top terminal: Flat Washer $\rightarrow$ Lock Washer $\rightarrow$ Nut. A minimum of 1.5 to 2 full bolt threads must protrude past the locknut.
Under FAA Advisory Circular AC 43.13-1B, what is the strict limitation regarding the installation of aluminum electrical conductor wire in aircraft?
What is the cross-sectional area in Circular Mils of a solid round electrical conductor having an outside diameter of 0.050 inches?
When routing an aircraft electrical wire bundle adjacent to combustible fluid plumbing (fuel or hydraulic lines) per AC 43.13-1B, which installation rule must be strictly followed?
According to AC 43.13-1B Chapter 11, what is the maximum number of terminal lugs that may be connected to any single electrical junction stud or bus bar post?