15.4 Cloud & Service Provider Governance
Key Takeaways
Allocate cloud duties by service model and specific offering, then verify both provider and customer controls. Each party can have independent legal and contractual duties.
Distinguish CSA STAR Level 1 self-assessment from Level 2 independent assurance, and inspect what a certificate or attestation covers.
Current FedRAMP rules offer Rev5 and 20x certification routes during transition. The JAB provisional ATO is historical. Federal agencies still evaluate and authorize their own use.
Assess whether HIPAA requires a BAA and whether the GDPR requires Article 28 processing terms and a separate Chapter V transfer mechanism.
Test portability, data restoration and actual ability to run the service. Escrow can support continuity when deposits and release rights are usable.
Cloud and Service Provider Governance
Compare cloud offerings by their service boundaries, customer obligations, evidence and exit paths. A provider's assurance covers a defined offering and time period. Plan for the controls the customer must operate and how it will verify the provider's controls. Document which entity makes each decision and who must be informed when evidence or service ownership changes.
Shared responsibility and evidence
| Model | Typical provider responsibility | Customer responsibility to verify |
|---|---|---|
| IaaS | Physical infrastructure, host software and the underlying network. | Guest OS and applications, guest patching, tenant network policy, data and access. |
| PaaS | Physical and underlying platform layers, including the managed runtime or database engine under the contract. | Customer code, identities, exposed security settings, data handling and accepted configurations. |
| SaaS | Operation and updating of the provider application stack and infrastructure. | Tenant identity and access, administration exposed to the customer, client endpoints, sharing, data use and monitoring. |
Check the actual offering and contract for shared areas. One managed database service may expose configuration and encryption choices that another service handles for the customer. Assign an owner and source of evidence for each obligation. For example, confirm which party produces audit logs, who exports them, how long each can retain them and how test results reach the customer. A customer retains responsibility for its own choices and obligations. Providers can independently have statutory, contractual and operational obligations, including as a HIPAA business associate or GDPR processor. Microsoft Azure shared responsibility · HHS cloud computing guidance
Evaluate which assurance serves the decision
| Evidence | Use and limitations |
|---|---|
| CSA STAR Level 1 | A provider can publish a self-assessment using the Consensus Assessments Initiative Questionnaire (CAIQ). An optional automated review under the current program is distinct from an independent audit. Check completeness and seek supporting evidence where the risk warrants it. |
| CSA STAR Level 2 | Independent assurance options include STAR Certification (ISO/IEC 27001 plus the Cloud Controls Matrix) and STAR Attestation (SOC 2 plus the matrix). Check the offering, dates, scope, exclusions and the responsibilities assigned to the customer. |
| SOC 2 | A Type 1 report addresses the description and design of controls as of a specified date. Type 2 also addresses operating effectiveness over its stated period. Inspect coverage, test exceptions and complementary user-entity controls. SOC 3 is a separate general-use report with less detailed information. |
| ISO cloud guidance | ISO/IEC 27017:2026 gives cloud security control guidance based on ISO/IEC 27002. ISO/IEC 27018:2025 provides guidance for public cloud providers acting as PII processors. Check exactly what an offered certificate or report covers before deciding whether it addresses a gap. |
In a procurement comparison, a STAR Level 2 certificate and a SOC 2 Type 2 report may provide more independent evidence than a self-assessment, but the stronger package can still omit the region or service used. Assess whether reports cover stated requirements and consider specific follow-up evidence, controls and supplier commitments. CSA STAR program · AICPA SOC 2 reporting elements · AICPA SOC 3 · ISO/IEC 27017:2026 · ISO/IEC 27018:2025
FedRAMP and the agency decision
The Federal Risk and Authorization Management Program (FedRAMP) provides reusable cloud security assessment and authorization information for federal agencies. Scope depends on the federal use case. A commercial entity using a service for its own purposes does not automatically become subject to FedRAMP because it operates in a regulated sector.
- Authorization history and transition. The Joint Authorization Board (JAB) provisional ATO was a legacy path. OMB Memorandum M-24-15 replaced the prior policy structure. Under the 2026 transition, the FedRAMP program offers Rev5 and 20x certification routes. Rev5 draws on NIST SP 800-53 Rev. 5 controls. 20x uses the applicable program rules and Key Security Indicators, with automated validation requirements where specified. Rev5 Agency Certification requires the sponsoring agency's ATO documentation, and specific transition pathways allow certain Rev5 Program Certification applicants without a sponsor. Check the program's eligibility and milestone dates for the actual offering.
- Impact versus certification. Under FIPS 199, low, moderate and high describe potential impact if confidentiality, integrity or availability is lost. Class and type in the current FedRAMP Marketplace describe the applicable certification evidence and rules. They do not set the agency information system's security category. In November 2026 both legacy designations and newer certifications can matter during transition. The current program schedule sets general mandatory adoption of the 2026 rules for January 1, 2027, with specific dates by rule.
- Reuse and ongoing oversight. Verify the Marketplace status, certified service boundary, evidence and ongoing requirements for the intended service. An agency uses the program's evidence to inform its own authorization of the agency system or use. Its authorizing official remains responsible for the agency's risk decision. Where the agency integrates a certified storage offering, determine whether the planned features and integrations are covered and which identity, logging and data controls remain the agency's responsibility. Track applicable ongoing evidence, changes and open issues. Do not infer authorization for a new workflow from a vendor's company-wide claim.
OMB M-24-15 · FedRAMP transition dates · FedRAMP certification paths · FedRAMP classes · FedRAMP 20x Class C rules · FIPS 199
Business associate arrangements and data transfers
HIPAA. A cloud provider that creates, receives, maintains or transmits electronic PHI on behalf of a covered entity or business associate is generally a business associate or subcontractor business associate. Persistent storage can qualify even if the cloud provider lacks access to the encryption key. Contractual assurances through a Business Associate Agreement (BAA) describe permitted use and disclosure, safeguards, incident and breach reporting, and applicable obligations for subcontractors. The parties also have responsibilities under applicable HIPAA rules. Evaluate what services and regions are covered by the agreement, audit evidence, and how the provider helps the customer meet its obligations. An offer of a BAA is insufficient to establish security of a customer configuration. HHS cloud computing guidance
GDPR. When a covered controller engages a processor, Article 28 requires a contract or other binding legal act with specified terms covering matters such as instructions, security, subprocessors and assistance with the controller's duties. Separately, evaluate Chapter V whenever the arrangement involves an applicable international transfer. Identify actual recipient, location, onward transfers and whether an adequacy decision applies. The European Commission's 2023 EU–U.S. Data Privacy Framework adequacy decision applies to covered transfers to participating U.S. organizations. Verify current participation and scope rather than using the vendor's nationality or an old Privacy Shield listing.
Where adequacy does not apply, assess appropriate safeguards, such as applicable Standard Contractual Clauses (SCCs). Evaluate the specific transfer and destination conditions, and adopt effective supplementary measures where needed. Encryption with keys held away from a provider can protect data in a storage-only scenario when the provider never needs plaintext. Customer-managed keys alone do not address access to plaintext during processing. Where necessary safeguards cannot be made effective, change or suspend the proposed transfer. Have counsel validate the transfer route and technical teams verify the data flow and access controls. GDPR Articles 28 and 44–49 · European Commission EU–U.S. data transfers · EDPB recommendations on supplementary measures
Exit and continuity
Choose whether to avoid, accept or mitigate a specific provider dependency. A proprietary data service may support the business well and still require a reliable exit plan. Identify dependent APIs, data formats, identity and logging integrations, network capacity, build artifacts and third-party licenses. Use abstraction or portable formats where justified, and validate recovery and integrations by rehearsal. A container alone does not make the surrounding cloud dependencies portable.
Set contractual export rights, time, formats, assistance, fees and access after termination. Test that data, metadata and key records can be restored in a suitable replacement environment. Track how data is returned or deleted and how exceptions or legally required retention are handled. Estimate export and restoration time against continuity needs.
Worked decision. A bank depends on a proprietary service whose source and build process can be operated by a replacement vendor. Negotiate a third-party escrow arrangement if that option addresses the continuity risk. Define what must be deposited, updates, test builds, release conditions and enforceable rights to use the released assets. Rehearse deployment using the deposit, a verified data export, and customer-owned credentials. Check dependencies and licenses with counsel. Release alone does not make a service operable. If the service cannot be stood up independently, prioritize continuity through alternative hosting, data migration or substitutable processes. UK Cabinet Office supplier continuity and escrow guidance
A federal agency is comparing two hosted services for an in-scope use. One supplies a CSA STAR Level 1 CAIQ for that service. The other supplies a STAR Level 2 certification and a current FedRAMP certification for the proposed offering. How should the CISO advise the agency?
Treat the CAIQ as independent assurance and authorize whichever offering is less expensive.
Verify the scope of the independent STAR evidence and reuse the in-scope FedRAMP package, while assessing agency responsibilities and completing the agency authorization.
Treat the FedRAMP listing as federal risk acceptance for every agency and use case without further evaluation.
Ask the provider to obtain a new JAB provisional authorization so that the agency can avoid reviewing service boundaries.
A firm relies on a proprietary cloud application and wants the ability to keep it running through a supplier failure. A continuity exercise confirms a replacement team can operate the system if it obtains usable build materials, data and rights. Which option addresses the identified dependency?
Require more liability insurance while leaving the software and data continuity gap unchanged.
Request a copy of the current source tree without build dependencies, contractual rights or a rehearsal.
Use a verified escrow deposit with necessary build and deployment materials, defined release and license terms, and a tested data export and restoration plan.
Rely on a termination clause while leaving the export formats and access period to be discussed after failure.
An EU controller considers a U.S. cloud processor that is not covered by the EU–U.S. Data Privacy Framework for the proposed transfer. The application must process the data in plaintext in the provider environment. Which step should the CISO take with privacy counsel before approving the transfer?
Treat an Article 28 processor contract as sufficient on its own for the international transfer.
Rely on provider-held encryption keys because at-rest encryption eliminates access during processing.
Proceed with standard clauses without checking the applicable transfer circumstances.
Confirm Article 28 terms and a valid Chapter V route, assess the actual transfer and access risks, and redesign or suspend it if an appropriate mechanism and effective safeguards cannot be established.
Sections you finish are checked off in the contents.