2.3 Cleaning & Disinfecting Contaminated Tools, Pedicure Equipment & the Daily Workstation
Key Takeaways
Colorado Rule 1.7(B) requires cleaning and disinfecting tools before each client and at day's end, and nail stations and other common equipment at least daily.
Colorado requires every pedicure bowl to be cleaned and disinfected according to the manufacturer's label before each client (4 CCR 731-1, Rule 1.7(B)(7)).
Disinfection works only on a cleaned, non-porous item fully immersed or kept wet for the label's full contact time; organic debris shields microbes and weakens the disinfectant.
Biofilm in whirlpool pedicure plumbing can shelter Mycobacterium fortuitum; in a 2000 California outbreak, more than 100 pedicure clients developed leg boils.
Colorado has no pedicure-log rule; between-client, daily and weekly spa routines in textbooks come from manufacturer guidance and other states' rules.
The Three Targets on the PSI Outline
PSI's Domain 1 asks you to know the methods and procedures for cleaning and disinfecting three kinds of things: contaminated tools, machines and equipment, and the daily workstation. Colorado's Rule 1.7 supplies the legal requirements. The textbooks PSI uses supply the step-by-step procedures. Keep the two separate in your head: on the theory test you will be asked for the correct procedure, and in a Colorado salon you will be inspected against the rule.
What Colorado Rule 1.7(B) Requires
Licensees must clean and disinfect:
- equipment, tools, implements and supplies, so that clean and disinfected implements are ready before each client's service;
- common work areas and equipment at least daily, including chairs, treatment tables and nail stations, according to the manufacturer's instructions;
- soiled or contaminated tools, implements and supplies before use on each client and at the end of each day;
- all non-porous items, including multi-use items, before use, and equipment used on multiple clients between each client;
- non-electrical items such as pushers, nippers and plastic or metal spatulas, according to the manufacturer's instructions;
- electrical items, including nail files (electric files), according to the manufacturer's instructions; and
- all pedicure bowls according to the manufacturer's label before each client.
Colorado defines the disinfectant as an EPA-registered bactericidal, viricidal and fungicidal disinfectant approved for use in hospital settings, used at the label's dilution ratio and contact time. A UV light box does not count, and the rules state that sterilization is not required.
Procedure 1: Contaminated Multi-Use Tools
Use this sequence for metal pushers, nippers, clippers, metal or glass files, plastic spatulas and similar non-porous implements:
- Remove debris. Brush away nail dust, product and skin.
- Clean. Wash with soap or detergent and warm water, scrubbing hinges and serrations with a clean brush. Colorado defines cleaning as removing visible debris so the item is ready for disinfection, and notes that cleaning alone "does not make multi-use items safe for use."
- Rinse and dry. Water left on the tool dilutes the disinfectant.
- Disinfect. Fully immerse the tool in the disinfectant, or keep it wet with a spray or wipe the label allows, for the entire contact time. Joints must be open and nothing may stick out above the liquid.
- Remove without recontaminating. Use clean tongs or clean, gloved hands.
- Rinse if the label says to, then dry with a clean towel.
- Store in a clean, covered container labeled "disinfected," "ready to use" or "clean" (Rule 1.7(D)(5)).
Used tools wait in a closed, covered, clearly marked container with solid sides that can itself be disinfected and is disinfected daily. They may never go into clothes, aprons, pockets, bags or holsters (Rule 1.7(D)(6)).
Why Cleaning Must Come First
Organic matter such as skin cells, oils, product residue and blood does two things to a disinfectant. It physically shields microorganisms underneath it, and it can react with and use up the active ingredient. A disinfectant label's efficacy claims assume the item was pre-cleaned, so skipping step 2 is an exam trap and a real-world failure.
Procedure 2: Machines and Equipment
| Equipment | Cleaning and disinfection approach |
|---|---|
| Electric file handpiece and cord | Clean and disinfect surfaces per the manufacturer; never immerse the handpiece |
| Electric file bits | Remove debris, clean, and disinfect per the manufacturer before reuse; sanding bands cannot be disinfected and are single-use |
| UV/LED lamps | Wipe surfaces and the base plate with disinfectant per the manufacturer |
| Paraffin unit | Keep covered; portion wax per client so the unused supply is never contaminated (Rule 1.7(K)(5)) |
| Towel warmer | Clean and disinfect daily and leave open overnight to dry (Rule 1.7(I)(5)) |
| Pedicure spa or bowl | Clean and disinfect per the manufacturer's label before each client (Rule 1.7(B)(7)) |
Disinfected electrical items cannot go into a closed "clean" container if they have a cord. Store them on a clean stand or hook, or on a clean towel covered with a clean paper or cloth towel (Rule 1.7(D)(5)).
Pedicure Equipment: Types and Risks
- Whirlpool (piped) spas circulate water through hidden pipes and jets. The plumbing gives debris and biofilm a place to collect where you cannot scrub.
- Pipeless units use a removable impeller or jet in the bowl with no internal pipes, so every surface can be reached.
- Non-whirlpool basins and portable tubs are the simplest to clean.
- Disposable liners are discarded after each client. Follow the bowl manufacturer's label for what cleaning is still required underneath.
Biofilm is a colony of microorganisms living in a sticky, protective matrix that attaches to wet surfaces such as pipes, jets and screens. Disinfectants struggle to reach organisms inside it. Mycobacterium fortuitum, an environmental bacterium, can live in pedicure-spa biofilm. In 2000, an outbreak linked to whirlpool footbaths at one California salon gave more than 100 clients painful boils on their lower legs. Many had shaved their legs shortly before the pedicure, and the shaving nicks gave the bacteria an entry point. This is why textbooks advise clients not to shave their legs in the day or two before a pedicure.
A Typical Spa Routine
Colorado's rule tells you to follow the manufacturer's label. Textbooks and manufacturers commonly describe this routine, which grew out of other states' rules:
- After each client: drain; remove visible debris; scrub the bowl, jets and screens with soap or detergent; rinse; refill with clean water and the correct dose of hospital disinfectant; circulate (for whirlpool units) for the label's full contact time; drain, rinse and wipe dry.
- End of day: remove the screen, footplate or impeller; scrub behind and inside them; disinfect the parts and the bowl; reassemble; circulate disinfectant; drain and dry, or leave as the manufacturer directs.
- Weekly or as directed: a longer disinfectant or chelating-detergent cycle that removes mineral buildup and film.
Colorado does not require a pedicure cleaning log. A salon can keep one as an internal control, but a Colorado inspector checks the result: clean, disinfected bowls and proper product use.
Procedure 3: The Daily Workstation
Before the first client: clean, then disinfect, the table surface, armrest, drawer pulls, lamp and chair according to the disinfectant's directions. Lay a fresh towel or new paper cover. Stock disinfected implements in labeled clean storage and single-use items in clean, covered containers or their original packaging. Check that hand sanitizer is available for clients (Rule 1.7(C)(1)).
Between clients: remove used towels into a closed soiled-linen container. Put used implements in the closed used-items container and single-use items in the trash. Clean and disinfect every surface that touched skin or body fluid (Rule 1.7(C)(3)). Replace the towel or table cover.
End of day: empty trash containers, which must have solid sides and a liner. Clean and disinfect the station and the used-implement container. Clean all tools and disinfect them for tomorrow. Clean the soiled-linen container daily and disinfect it weekly (Rule 1.7(D)(2)).
Important
An exam question about the "first step" of disinfecting anything almost always wants cleaning. A Colorado inspector asking about your disinfectant wants to see an EPA registration number, a hospital claim and bactericidal, viricidal and fungicidal claims on the label. They will also want proof that you follow its dilution and contact time.
What is the correct first step before placing used metal nippers into a hospital disinfectant?
Cleaning them with soap or detergent and water to remove all visible debris
Placing them in a UV cabinet for ten minutes
Wrapping them in a towel and storing them until the end of the day
Spraying the nippers with 70% alcohol and air drying them
How often does Colorado Rule 1.7(B)(7) require pedicure bowls to be cleaned and disinfected?
Only when a client has visible foot disease
Once a day at closing, using any household cleaner
Before each client's use, according to the manufacturer's label
Once a week, with the date recorded in a pedicure log
Why are whirlpool pedicure spas with internal piping a particular infection-control concern?
Biofilm can form in hidden plumbing and shelter bacteria from disinfectants
They require sterilization, which salons cannot perform
Their plastic bowls absorb disinfectant over time and slowly release it onto clients' skin
Their jets raise water temperature above safe limits
Where should a disinfected electric file with an attached cord be stored under Colorado's rules?
Inside a closed container labeled "clean" with other implements
On a clean stand or hook, or on a clean towel covered with a clean towel
In the technician's apron pocket so it stays within reach
Inside the used-implement container until the next client
Sections you finish are checked off in the contents.