15.4 Detention, Retention & Proprietary BMPs: Dry/Wet Basins, Wetlands, Inline Storage, Catch Basin Inserts, Vaults, and Manufactured Devices
Key Takeaways
Detention basins drain completely through a calibrated outlet orifice so the floor is DRY between storms (24- to 72-hour drawdown in Dry Extended Detention basins), whereas Retention (Wet Detention) basins maintain a permanent 4- to 8-foot pool year-round that achieves potentially substantial TSS removal, depending on design and operation via plug-flow displacement.
Wet Detention Basins require an inlet sediment forebay (dredged at 50% capacity loss) and a shallow 6- to 12-inch vegetated aquatic safety bench around the shoreline, while Constructed Wetlands combine deep forebays/micropools (supporting mosquito-eating Gambusia fish) with meandering high- and low-marsh emergent plant zones.
Inline Storage detains runoff inside oversized storm pipes behind a vortex valve or weir wall, while Catch Basin Inserts trap trash, coarse grit, and oil right under inlet grates and must be cleaned out whenever they reach 50% capacity.
Underground Vaults and Manufactured/Proprietary Devices (hydrodynamic vortex separators and media filtration cartridge vaults) are OSHA Permit-Required Confined Spaces (29 CFR 1910.146); CESSWI inspectors must inspect them from the surface using a flashlight, mirror, pole camera, and graduated sludge rod unless full confined-space entry protocols are active.
Multipurpose basins and permanent operation
A multipurpose basin serves more than one stated objective, such as temporary construction-sediment control, permanent water-quality treatment, peak-flow detention, and flood storage. Its functions can occupy different elevations and change between construction phases. The label does not mean that the same outlet or storage volume is suitable for every phase. During construction, inspect the temporary sediment-storage zone, surface withdrawal, stabilized inflow, embankment, and spillway against the construction detail. At conversion, verify sediment removal, restoration of the design elevations, installation of the permanent outlet, and completion of vegetation and access provisions before accepting the facility for permanent service.
A useful closeout record identifies each phase and responsible owner. For example, a development’s basin may begin with a temporary skimmer and later use a multistage permanent outlet. Leaving construction sediment in the basin reduces the permanent water-quality and flood-storage volumes even when its slopes look green. Record sediment elevations and compare the as-built survey with the permanent plan; the authorized designer or owner determines whether capacity is acceptable. Photograph the outlet before and after conversion and keep the maintenance access clear.
Long-term inspection checks sediment and litter, eroding inlets, outlet blockage, vegetation survival, embankment settlement, and evidence of overtopping. The O&M agreement assigns responsibility and access, while the approved plan supplies cleanout levels and inspection intervals. Multipurpose use may add public access or recreation, which also requires the owner’s safety provisions. A construction NOT ends that construction permit coverage; it does not extinguish post-construction maintenance duties or establish a basin’s hydraulic adequacy by itself.
Note
Using dimensions in this section: Construction dimensions, material sizes, slopes, cleanout fractions, and drawdown ranges below describe example practice details. Verify the approved design, manufacturer instructions, and applicable permit before using a number as an inspection acceptance criterion. Regulatory thresholds identified explicitly as EPA/OSHA requirements remain distinct.
Surface Detention vs. Retention Basins: Core Hydraulic & Water-Quality Distinctions
On the CESSWI exam, candidates must clearly distinguish between Detention and Retention surface impoundments:
- Detention Basin (Dry Basin): Temporarily stores stormwater runoff during a storm event and releases of the stored water through a calibrated outlet structure so the basin floor is normally DRY between storm events.
- Retention Basin (Wet Detention Basin / Wet Pond): Maintains a permanent pool of water ( deep) year-round and temporarily detains additional live storm runoff storage above the normal pool elevation.
1. Multi-Purpose Detention Basin (12.7.4) and Dry Extended Detention Basin (12.7.5)
Multi-Purpose Detention Basin (12.7.4)
A Multi-Purpose Detention Basin is a dry flood-control detention basin specifically graded and drained (often incorporating subsurface turf underdrains and sandy root-zone soils) so its flat vegetated floor serves a secondary community recreational or civic function during dry weather—such as municipal soccer and baseball fields, open park lawn, walking trails, or an outdoor amphitheater—while detaining 10-year to 100-year flood peaks during major storms. After floodwaters recede, maintenance crews clear any floatable debris and mud film before reopening the recreational facility.
Dry Extended Detention (ED) Basin (12.7.5)
Whereas a conventional flood-control dry detention basin drains rapidly (often within ) solely to shave peak flood discharge () and achieves poor fine-sediment removal ( TSS), a Dry Extended Detention (ED) Basin is engineered for both peak-flow attenuation and water quality treatment:
- Extended Drawdown Time (): A small, calibrated low-flow water-quality orifice (protected against clogging by an external perforated trash rack/hood or an internal reverse-slope pipe) at the invert of the multi-stage outlet riser holds back and slowly releases the Water Quality Volume () over ( typical design target), giving fine silt particles quiescent residence time to settle out ( TSS removal).
- Forebay, Low-Flow Channel & Micropool: Includes an inlet sediment forebay to trap coarse sand, a stabilized low-flow pilot channel or shallow wet outlet micropool (preventing bottom scour and orifice clogging as the last few inches drain), and an earthen embankment dam with an armored emergency spillway.
- Critical Earthen Dam Inspection Rule: CESSWI inspectors must ensure earthen embankment dams, side slopes, and emergency spillways are kept completely free of trees and woody brush (whose decaying roots create internal seepage piping channels that can breach the dam) as well as burrowing animals (groundhogs, muskrats, beavers).
2. Wet Detention Basin / Retention Pond (12.7.6) and Constructed Wetlands (12.7.7)
Wet Detention Basin / Retention Pond (12.7.6)
A Wet Detention Basin (Retention Pond) maintains a permanent pool of water ( deep) throughout the year, overlaid by temporary live extended-detention and flood-control storage zones.
- Superior Water Quality via Plug-Flow Displacement: When a storm occurs, incoming runoff enters the inlet and pushes out (displaces) the quiescent, already-treated water that has been sitting in the permanent pool since the previous storm. Simultaneously, the deep permanent water cushion absorbs incoming kinetic energy so settled bottom muck cannot be scoured and resuspended. Consequently, wet detention basins achieve TSS removal, along with substantial biological removal of dissolved nitrogen and phosphorus (consumed by aquatic plants and phytoplankton) and trace metals.
- Four Mandatory Structural & Safety Features:
- Inlet Sediment Forebay: Sized to hold of the total permanent pool volume and separated from the main pool by a submerged rock berm or gabion weir. Equipped with a permanent vertical depth staff gauge so inspectors know to trigger maintenance dredging when forebay capacity is reduced by (or when the main pool loses of its volume).
- Vegetated Aquatic Bench (Safety Shelf): A shallow deep, wide shelf graded around the inside shoreline perimeter and planted with dense emergent wetland plants. The aquatic bench serves two vital functions: life safety (preventing children or maintenance workers who slip on the bank from plunging into of deep water) and biological polishing / wave-erosion protection.
- Non-Clogging Reverse-Slope or Hooded Outlet Riser: Withdraws water from approximately below the permanent pool surface so floating oil, grease, and trash cannot escape downstream.
- Anti-Seep Collars / Filter Diaphragms & Bottom Drain Valve: Prevents piping along the outlet barrel through the earthen dam and provides a lockable bottom drain valve to dewater the pond for periodic sediment dredging.
Constructed Wetlands (12.7.7)
Constructed Stormwater Wetlands are engineered shallow marsh systems that mimic natural wetland ecosystems, delivering the highest biological, biochemical, and physical pollutant removal of any surface basin (removing fine TSS, dissolved nitrate via anaerobic denitrification, dissolved phosphorus, fecal bacteria, hydrocarbons, and trace metals through dense stem filtration, microbial biofilms/periphyton coating submerged stems, and root-zone uptake).
- Multi-Zone Bathymetry (Depth Profile):
- Deep Inlet Forebay & Outlet Micropool ( deep): Settle coarse grit at the entrance, keep the outlet orifice free of marsh vegetation, and provide year-round deep-water habitat for predaceous mosquito-eating fish (such as Gambusia affinis mosquitofish) and dragonfly nymphs, naturally controlling mosquito larvae.
- Low-Marsh Zones ( deep) & High-Marsh Benches ( deep): Cover of the wetland footprint. Internal earthen berms and islands force water along a long, sinuous, meandering flow path (maximizing length-to-width ratio and residence time) through diverse native emergent aquatic macrophytes (bulrushes, pickerelweed, arrowhead, sedges, rushes). Inspectors check for invasive plant monocultures (such as invasive Phragmites or purple loosestrife) and forebay sediment depth.
3. Inline Storage (12.7.14), Catch Basin Inserts (12.7.15), Underground Vaults (12.7.16), and Manufactured Devices (12.7.18)
Inline Storage (12.7.14)
Inline Storage utilizes oversized storm sewer pipes, reinforced concrete box culverts, or manifolded large-diameter corrugated metal/HDPE pipes beneath roadways and parking lots—throttled at the downstream end by a vortex flow-control valve (hydro-brake), calibrated orifice plate, or weir wall inside a control manhole—to back up and detain stormwater runoff inside the storm pipe conveyance network itself.
Catch Basin Inserts (12.7.15)
Catch Basin Inserts are permanent drop-in stainless-steel, fiberglass, or polymer filter baskets, curb-throat hood trays, or multi-stage geotextile media pouches mounted inside storm drain inlets just below the grate or curb opening. They capture trash, floatable plastics, autumn leaves, coarse sand, and free petroleum hydrocarbons (using replaceable hydrophobic oil-absorbent pillows or booms suspended inside the basket). Because their holding volume is very small, catch basin inserts require frequent routine inspection and vacuum or manual cleanout—typically quarterly or whenever sediment and debris reach of basket capacity—to prevent inlet clogging and roadway flooding.
Underground Vaults (12.7.16)
Underground Vaults are large subterranean precast or cast-in-place reinforced concrete vaults, multi-barrel corrugated metal/HDPE pipe manifolds, or modular structural plastic arches buried beneath high-density urban parking lots, plazas, and buildings where zero surface land is available. They provide either underground flood detention (dry) or multi-chamber wet sedimentation and oil/grit separation.
Note
Using dimensions in this section: Construction dimensions, material sizes, slopes, cleanout fractions, and drawdown ranges below describe example practice details. Verify the approved design, manufacturer instructions, and applicable permit before using a number as an inspection acceptance criterion. Regulatory thresholds identified explicitly as EPA/OSHA requirements remain distinct.
Warning
CRITICAL INSPECTOR SAFETY RULE: OSHA Permit-Required Confined Spaces (29 CFR 1910.146 / 1926 Subpart AA)
Underground detention vaults (12.7.16), inline storage control manholes (12.7.14), underground sand filters (12.7.11), and deep proprietary treatment chambers (12.7.18) are OSHA Permit-Required Confined Spaces due to lethal atmospheric and physical hazards: oxygen deficiency ( from rotting organic muck or rusting steel), toxic hydrogen sulfide ( sewer/swamp gas) or carbon monoxide (), explosive methane or gasoline vapors (), and sudden flash-flood engulfment.
CESSWI Inspection Protocol: Never climb down into an underground vault or manhole during a routine inspection! Conduct all inspections from the ground surface through open access hatches using an intrinsically safe flashlight, mirror, telescoping pole camera, and a graduated sludge-measuring rod (stadia rod or clear core sampler / Sludge Judge). Physical entry is strictly prohibited unless a full OSHA confined-space entry permit, continuous 4-gas atmospheric monitoring ( , , , ), forced mechanical ventilation, full-body harness with retrieval tripod/winch, and trained topside attendant are active.
Note
Using dimensions in this section: Construction dimensions, material sizes, slopes, cleanout fractions, and drawdown ranges below describe example practice details. Verify the approved design, manufacturer instructions, and applicable permit before using a number as an inspection acceptance criterion. Regulatory thresholds identified explicitly as EPA/OSHA requirements remain distinct.
Manufactured / Proprietary Devices (12.7.18)
Manufactured (Proprietary) Treatment Devices are factory-engineered subterranean stormwater treatment units verified under standardized third-party testing protocols—most notably the New Jersey Corporation for Advanced Technology (NJCAT) and the Washington State Department of Ecology TAPE (Technology Assessment Protocol – Ecology) program. They fall into two primary engineering families:
- Hydrodynamic Separators (Swirl Concentrators / Vortex Separators):
- Compact cylindrical precast concrete manhole structures with no moving parts that direct incoming stormwater tangentially (or through an angled internal deflection cone/louver) into a circular separation chamber.
- The resulting cyclonic vortex (swirl) uses centrifugal and gravitational forces to spin coarse sand, road grit, and settleable solids inward and down into an isolated bottom storage sump (shielded from high-flow scouring and resuspension by an internal horizontal skirt/weir), while trapping floating oil, grease, and buoyant trash behind a submerged outlet baffle wall.
- Because hydrodynamic separators reliably remove of coarse sand/grit and floatables at high flow rates inside a single manhole footprint, they are widely installed as pretreatment units immediately upstream of underground infiltration trenches, underground detention vaults, or bioretention cells.
- Proprietary Media Filtration Cartridge Systems:
- Subterranean concrete vaults housing manifolded arrays of replaceable vertical filter cartridges filled with engineered filtration and sorptive media—such as expanded perlite, zeolite, granular activated carbon (GAC), or iron/alumina-amended media.
- As stormwater rises in the vault, it flows radially inward through the media cartridges into an underdrain manifold, achieving fine TSS removal along with chemical capture of dissolved heavy metals, phosphorus, and emulsified hydrocarbons.
- Maintained by pumping out the pretreatment sump with a vacuum truck (Vactor truck) when sediment reaches the manufacturer's depth limit (typically ) and replacing spent media cartridges every .
Decision & Inspection Flowchart: All 18 Post-Construction Stormwater BMPs
For the practice detail described in this section, with its stated example dimensions and maintenance criteria, why does a Wet Detention Basin / Retention Pond (12.7.6) achieve significantly higher removal of fine suspended solids (performance depending on design and operation) and dissolved nutrients than a conventional Dry Detention Basin?
Because a Wet Detention Basin infiltrates 100% of incoming runoff through an unlined gravel trench within 6 hours
Because a Wet Detention Basin uses replaceable activated-carbon cartridges inside an underground concrete vault
Because a Wet Detention Basin drains completely dry within 2 hours of every storm so wind can blow settled silt off the basin floor
Because its 4- to 8-foot permanent pool prevents resuspension of settled bottom sediment, treats runoff between storms via gravity settling and biological uptake, and discharges clean water during the next storm via plug-flow displacement
For the practice detail described in this section, with its stated example dimensions and maintenance criteria, a CESSWI inspector is scheduled to inspect an Underground Detention Vault (12.7.16) and a Manufactured Hydrodynamic Separator (12.7.18) beneath an urban shopping center parking lot to check sediment accumulation depth. What is the mandatory safety and inspection procedure?
Immediately climb down the manhole ladder into the vault with a tape measure while holding your breath to avoid inhaling hydrogen sulfide
Treat the underground vault and separator as OSHA Permit-Required Confined Spaces and perform the inspection from the ground surface through the access hatches using a flashlight, mirror, pole camera, and graduated sludge-measuring rod (Sludge Judge)
Pump gasoline exhaust into the manhole to displace stagnant air before descending without a harness or topside attendant
Skip inspecting underground vaults altogether because subterranean concrete structures never accumulate sediment or floatables
For the practice detail described in this section, with its stated example dimensions and maintenance criteria, how does a Manufactured Hydrodynamic Separator / Swirl Concentrator (12.7.18) remove pollutants from stormwater runoff, and how is it most commonly integrated into a treatment train?
It uses biological denitrification in a 100-foot forested buffer zone to remove dissolved nitrate from shallow groundwater
It spreads concentrated flow over a 0.0% level concrete weir lip into a dense turfgrass filter strip
It directs incoming flow tangentially into a cylindrical chamber to create a cyclonic vortex that helps separate coarse grit and sand into a bottom sump while trapping floating oil and trash behind a baffle wall, making it ideal as pretreatment upstream of infiltration or filtration BMPs
It relies on mosquitofish in a 6-inch-deep emergent wetland marsh to consume dissolved heavy metals