1.2 The Schematic Design Phase & Multi-Discipline Workflow
Key Takeaways
Schematic Design establishes preliminary spatial relationships, scale and systems under the executed agreement.
Coordinate site, structure, MEP and envelope before fixing massing and floor heights.
Gross area equals net program plus circulation, services and other unassigned area; efficiency is net divided by gross.
An area or coverage check does not establish complete zoning or building-code compliance.
1.2 The Schematic Design Phase & Multi-Discipline Workflow
The Schematic Design (SD) phase represents the transition from abstract programmatic data to tangible architectural form. During SD, the architect evaluates the owner's program, schedule, budget, site conditions, and regulatory constraints to develop preliminary design solutions exploring spatial relationships, scale, building massing, and basic technical systems.
Because decisions made during Schematic Design establish fundamental structural grids, vertical core locations, mechanical plant strategies, and floor-to-floor heights, effective multi-disciplinary coordination at this early phase is essential to avoid catastrophic redesigns during Design Development (DD) and Construction Documents (CD).
Contractual Framework: AIA Document B101-2017
The executed owner–architect agreement establishes the architect's services. AIA B101-2017 Article 3.2 is a common framework for Schematic Design, but it may be modified. Review the actual agreement rather than treating a model contract as a statute.
Key Architect Obligations Under Article 3.2
Schematic Design includes reviewing the program and budget, evaluating site and regulatory constraints, exploring alternatives, and preparing documents and a preliminary cost estimate for the owner's review. B101 calls for submission of the Schematic Design documents and an estimate of the Cost of the Work and a request for owner approval. The executed agreement determines documentation and authorization requirements; do not invent a universal written-approval clause or rely on an unverified subsection number.
Standard Schematic Design Deliverables
Schematic Design deliverables communicate the project's conceptual scale, aesthetic character, and technical feasibility without documenting exact construction fastening or complete specifications.
| Deliverable Item | Typical Content & Level of Detail | Interdisciplinary Contributors |
|---|---|---|
| Preliminary Site Plan | Property lines, zoning setbacks, building footprint, vehicular/pedestrian circulation, parking stalls, preliminary grading contours, utility connections | Architect, Civil Engineer, Landscape Architect |
| Schematic Floor Plans | Single-line or early double-line walls, room titles, dimensioned functional spaces, programmatic adjacencies, primary circulation paths, structural grid layout, vertical core locations | Architect, Structural Engineer, Program Planner |
| Preliminary Elevations | Massing profiles, fenestration percentages, primary exterior materials, relationship to existing and finished site grades, overall building height | Architect, Energy Consultant (fenestration ratio) |
| Building Sections | Floor-to-floor heights, finished ceiling heights, preliminary plenum allowances, relationship of basement to water table, structural depth profiles | Architect, Structural Engineer, Mechanical Engineer |
| Structural Narrative | Proposed framing materials (structural steel, cast-in-place concrete, mass timber), primary bay spacing, lateral force-resisting system (shear walls vs. moment frames) | Structural Engineer |
| MEP Systems Narrative | Proposed heating/cooling plant (central chiller/boiler vs. VRF), air distribution strategy, main electrical service capacity, transformer and generator locations | Mechanical, Electrical, and Plumbing Engineers |
| Outline Specifications | High-level summary of proposed materials, systems, and performance standards organized broadly by MasterFormat divisions (rather than full 3-part CSI specs) | Architect, Engineering Consultants, Specifier |
| Preliminary Cost Estimate | Order-of-magnitude cost model based on gross square footage ($/GSF) or volume metrics, including appropriate schematic design contingencies | Architect or Professional Cost Estimator |
Multi-Disciplinary Coordination Workflow
The architect acts as the primary integrator (the "master coordinator") of all engineering consultants. During Schematic Design, key technical inputs from each discipline establish fundamental spatial and financial boundaries:
1. Civil & Geotechnical Engineering
-
Geotechnical data: Use the geotechnical report to evaluate allowable bearing, total and differential settlement, seasonal groundwater, expansive or collapsible soils, and seismic site classification. Low bearing or high groundwater calls for comparison of engineered foundations, drainage, waterproofing and basement alternatives; a single bearing number does not automatically require piles or prohibit a basement.
-
Civil site utilities: Coordinate utility location, capacity and invert elevations. Fixtures that cannot discharge by gravity to an approved sewer connection may require an ejector system; a basement without such fixtures does not automatically require one merely because its floor is below the municipal sewer.
-
Stormwater Management: Site retention/detention pond footprints, pervious surfacing ratios, and bio-swale requirements determine buildable site boundaries.
2. Structural Engineering
-
Bay Spacing & Grid Alignment: Coordinating column grid spacing (e.g., for steel or for concrete flat slab) with subterranean parking layouts and upper-level partitions.
-
Member Depth Allowances: Rule-of-thumb structural depth sizing determines preliminary floor-to-floor heights. For example, a steel beam spanning with a depth-to-span ratio of requires a structural depth of (), plus fireproofing.
-
Lateral Resisting System: Locating shear walls around vertical elevator/stair cores or positioning perimeter braced frames where they do not obstruct vision glazing or doors.
3. Mechanical (HVAC), Electrical & Plumbing (MEP)
-
Central Plant Space Requirements: Boilers, chillers, and primary air handling units (AHUs) typically require of the building's gross area. Mechanical rooms must be positioned for outdoor air intake and exhaust louvers.
-
Vertical Shafts: Primary supply and return duct chases require approximately per of conditioned floor area and must align vertically through all stories.
-
Electrical Service & Switchgear: Utility transformers (dry-type interior vs. liquid-filled exterior pad-mounted), main switchboard clearances, and emergency generator ventilation/fuel storage routing.
-
Plumbing Chases: Wet-column stacking for public restrooms, kitchenettes, and laboratory drainage, ensuring adequate gravity slope for sanitary piping ( for pipes ; for pipes ).
Spatial Organization: Adjacency Matrices & Bubble Diagrams
Before drafting formal floor plans, architects use abstract diagrammatic tools to verify functional relationships:
-
Adjacency Matrix: A two-dimensional chart indexing every programmed space against all other spaces to designate degrees of required proximity: Direct Access (contiguous doors), Convenient Access (adjacent across a common corridor), Neutral / No Preference, or Separation Required (acoustic, visual, security, or hazardous contamination buffers).
-
Bubble Diagrams: Graphic translations of the adjacency matrix representing programmatic spaces as proportional circular bubbles connected by directional vectors representing circulation flows, sightlines, and acoustic boundaries.
-
Blocking & Stacking Diagrams: In multi-story structures, "stacking" determines the vertical assignment of program components (e.g., public retail on Ground Level, conference centers on Level 2, private offices on Levels 3–8), while "blocking" establishes horizontal departmental boundaries on individual floor plates.
Building Area Efficiencies & Net-to-Gross Calculations
A critical responsibility during Schematic Design is converting the owner's net functional program into a realistic gross building footprint that complies with zoning setbacks and Floor Area Ratio (FAR) caps.
Area Definitions
-
Net Assignable Area (NSF / Net Square Feet): The actual usable floor space assigned to specific functional activities (e.g., private offices, classrooms, patient treatment rooms, retail sales floor). NSF excludes circulation, restrooms, and shafts.
-
Tare Area (Unassignable Area): The supplementary space required to service the net functional areas, including corridors, lobbies, exit stairs, elevators, mechanical/electrical rooms, pipe chases, public restrooms, and structural column/wall thicknesses.
-
Gross Square Footage (GSF): The total constructed building area measured to the exterior face of enclosure walls, encompassing all enclosed floor plates: .
The Efficiency Ratio Formula
The relationship between net and gross area is expressed through the Efficiency Ratio:
Typical Building Type Efficiency Benchmarks
| Building Typology | Typical Efficiency Ratio | Primary Drivers of Tare Area |
|---|---|---|
| Commercial Office Building | 75%–85% | Central elevator core, dual exit stairs, core restrooms, multi-tenant perimeter corridors |
| Multi-Family Residential | 80%–85% | Double-loaded residential corridors, dual exit stair towers, elevator vestibule |
| Higher Education / University | 65%–72% | Wide circulation corridors for class change surges, public breakout lounges, restrooms |
| Laboratories & Research | 55%–65% | Massive chemical fume hood exhaust plenums, utility chases, hazardous storage, ante-rooms |
| Acute Care Hospitals | 50%–60% | Wide 8-foot gurney corridors, interstitial mechanical floors, massive MEP shafts, isolation airlocks |
| Museums & Performing Arts | 50%–60% | Monumental atrium circulation, acoustic sound locks, public lobbies, loading docks |
Worked Scenario: Net-to-Gross Sizing for a Municipal Branch Library
Scenario
A municipal library authority provides a functional program requiring of functional space (reading rooms, stacks, children's pavilion, staff offices, and meeting halls). Historical data indicates that branch libraries achieve a building efficiency ratio of (). The zoning ordinance limits maximum lot coverage to on a parcel, and restricts building height to two stories.
Step-by-Step Resolution
-
Step 1: Calculate Total Required Gross Square Footage (GSF)
- .
- Unassignable Tare Area = (dedicated to lobbies, stairs, elevator, mechanical rooms, restrooms, and wall footprints).
-
Step 2: Determine Footprint for a 2-Story Massing
- Assuming equal floor distribution: .
-
Step 3: Verify Zoning Lot Coverage Compliance
- .
- The proposed footprint () exactly matches the maximum allowable coverage (), satisfying this coverage test. Setbacks, FAR, access, height, area and other applicable requirements still require separate checks.
Under an unmodified B101 schematic-design workflow, what is the appropriate phase-end action?
Submit fully detailed construction documents for a permit.
Obtain a building permit before any owner review.
Obtain three construction bids before developing schematic alternatives.
Submit the Schematic Design documents and an estimate of the Cost of the Work and request owner approval.
A programming document for a specialized hospital surgical suite requires 36,000 Net Square Feet (NSF) of assignable space. If the typical building efficiency ratio for this hospital department is 60%, what is the required Gross Square Footage (GSF)?
60,000 GSF
21,600 GSF
54,000 GSF
72,000 GSF
During Schematic Design, the architect must coordinate finished ceiling heights, structural framing, and mechanical air distribution to establish the building's floor-to-floor height. Which strategy represents the correct multi-disciplinary approach?
Set the floor-to-floor height strictly to 10 feet throughout, and require the structural engineer to cut holes through steel beam webs for all main HVAC supply ducts without engineering calculation.
Defer all plenum depth decisions until the Construction Documents phase when the general contractor selects the mechanical subcontractor.
Calculate the combined dimension of the deepest structural beam or girder, primary HVAC duct cross-sections, sloped plumbing lines, and recessed lighting to establish the necessary plenum depth and floor-to-floor height.
Allow the mechanical engineer to determine the floor-to-floor height independently based entirely on the total cooling tonnage of the central rooftop chillers.
Sections you finish are checked off in the contents.