100+ Free NV Fire Detection Specialty Practice Questions
Prepare for the Nevada C-41C Fire Detection Contractor Examination exam with instant access — no signup required.
Loading practice questions...
Explore More Nevada NSCB Contractor Examinations
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
Key Facts: NV Fire Detection Specialty Exam
55 Q
Official Exam Questions
PSI Nevada Contractor CIB updated 3/25/2026
39 of 55 points
Passing Score
PSI Nevada Contractor CIB updated 3/25/2026
2 hours
Time Allowed
PSI Nevada Contractor CIB updated 3/25/2026
USD 95
PSI Exam Fee (one portion)
PSI Nevada Contractor CIB updated 3/25/2026
Open Book
Book Policy
PSI Nevada Contractor CIB updated 3/25/2026
Nevada C-41C Fire Detection Contractor Examination is the official NSCB/PSI open book exam: 55 questions, 39 of 55 points, 2 hours, USD 95 (bulletin 270, updated 3/25/2026). Official delivery: English.
Sample NV Fire Detection Specialty Practice Questions
Try these sample questions to test your NV Fire Detection Specialty exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.
1On a 24-volt DC initiating circuit, a conventional smoke detector draws 45 mA in alarm. What is the detector's equivalent resistance while in alarm?
2Four identical 24-volt horn-strobes are connected in parallel. Each draws 80 mA in alarm. What is the total alarm current the notification-appliance circuit must supply?
3A 24-volt notification appliance draws 180 mA while sounding and flashing. How much power does it consume?
4In the AWG system used on C-41C fire-detection circuits, which copper conductor has the lowest resistance per 1,000 feet?
5A 24.0-volt control-unit output feeds a notification circuit whose total conductor resistance is 2.4 ohms. Alarm current is 1.25 A. What voltage remains at the last appliance?
6On a conventional Class B initiating-device circuit that uses an end-of-line resistor, which condition typically produces a trouble signal rather than an alarm?
7Why are most listed 24-volt notification appliances polarized on a C-41C notification-appliance circuit?
8A C-41C installer measures continuity on a de-energized notification pair and reads nearly 0 ohms between the two conductors, with the end-of-line device disconnected. What does that reading indicate?
9A 24-volt notification circuit uses 400 feet of 16 AWG copper pair. Uncoated 16 AWG copper is 4.02 ohms per 1,000 feet per conductor. Alarm current is 1.50 A. What is the approximate voltage drop in the pair?
10Which NEC 2017 article governs the installation of wiring and equipment for fire-alarm systems, including circuits controlled and powered by the fire-alarm system?
About the NV Fire Detection Specialty Exam
The Nevada C-41C Fire Detection Contractor Examination is the official Nevada State Contractors Board trade examination administered by PSI Services LLC. The official exam has 55 scored questions. Passing is 39 of 55 points in 2 hours. The examination is open book. National Electrical Code, 2017 and NFPA 72, 2013 (allowed in center). PSI lists USD 95 for one examination portion and USD 140 if taken with CMS; otherwise USD 95 per trade exam (Candidate Information Bulletin 270, updated 3/25/2026). NSCB requires a separate CMS examination for most new applicants, plus a USD 300 application fee and a USD 600 biennial license fee. This English-language MCQ bank is a study aid, not an official PSI form. It does not replace required trade experience, board approval, fingerprints, bonding, or the official examination.
Assessment
Open Book computer-based multiple-choice. National Electrical Code, 2017 and NFPA 72, 2013 (allowed in center)
Time Limit
2 hours
Passing Score
39 of 55 points
Exam Fee
USD 95 (PSI Services LLC (for the Nevada State Contractors Board))
NV Fire Detection Specialty Exam Content Outline
General Electrical Knowledge
General Electrical Knowledge (5 items)
Wiring
Wiring (8 items)
Grounding
Grounding (3 items)
Power Supply
Power Supply (5 items)
Detectors
Detectors (15 items)
Alarms Notification
Alarms Notification (14 items)
General Regulations
General Regulations (5 items)
How to Pass the NV Fire Detection Specialty Exam
What You Need to Know
- Passing score: 39 of 55 points
- Assessment: Open Book computer-based multiple-choice. National Electrical Code, 2017 and NFPA 72, 2013 (allowed in center)
- Time limit: 2 hours
- Exam fee: USD 95
Keys to Passing
- Work through all 100 available questions
- Review every answer and explanation
- Track weak areas and revisit them
- Use our AI tutor for tough concepts
NV Fire Detection Specialty Study Tips from Top Performers
Frequently Asked Questions
How many questions are on the Nevada C-41C Fire Detection Contractor Examination?
The official PSI examination has 55 scored questions. Passing is 39 of 55 points within 2 hours (Candidate Information Bulletin 270, updated 3/25/2026).
How much does the NV C-41C exam cost?
PSI lists USD 95 for one examination portion. Two portions cost USD 140 only if the second portion is CMS. NSCB charges a separate USD 300 application fee and USD 600 biennial license fee.
Is the NV C-41C exam open book?
Yes. PSI lists this examination as open book. National Electrical Code, 2017 and NFPA 72, 2013 (allowed in center)
Do I still need the CMS examination?
CMS is the required Nevada business-and-law examination. Most new applicants must pass CMS and a trade examination for the requested classification. In most cases you will not retake an exam if you have actively served as a qualified employee in the same classification within the last four years.