2026 Statistics

Key Facts: NV C-4F Sheet Metal Studs Exam

20 Q

Official Exam Questions

PSI Nevada Contractor CIB updated 3/25/2026

70%

Passing Score

PSI Nevada Contractor CIB updated 3/25/2026

1 hour

Time Allowed

PSI Nevada Contractor CIB updated 3/25/2026

USD 95

PSI Exam Fee (one portion)

PSI Nevada Contractor CIB updated 3/25/2026

Open Book

Book Policy

PSI Nevada Contractor CIB updated 3/25/2026

Nevada C-4F Sheet Metal Studs Contractor Examination is the official NSCB/PSI open book exam: 20 questions, 70% (14 of 20 points), 1 hour, USD 95 (bulletin 270, updated 3/25/2026). Official delivery: English.

Sample NV C-4F Sheet Metal Studs Practice Questions

Try these sample questions to test your NV C-4F Sheet Metal Studs exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Under NAC 624.220, what work does a Nevada C-4F Sheet Metal Studs license authorize?
A.Erection and installation of sheet-metal studs for ceiling framing and nonstructural partitioning
B.Installation of wood studs and structural steel beams
C.Welding of structural wide-flange columns
D.Taping and finishing of gypsum wallboard only
Explanation: NAC 624.220(2)(f) defines C-4F as the erection and installation of sheet-metal studs for framing ceilings and for nonstructural partitioning. The same sentence excludes wood and structural steel framing. Taping and finishing is C-4C; gypsum board hanging is C-4E.
2Which framing material is expressly outside the Nevada C-4F subclassification?
A.25-gauge drywall studs
B.Cold-formed steel ceiling furring channels
C.Wood studs or structural steel used for framing
D.Nonstructural 3-5/8-inch steel studs
Explanation: NAC 624.220(2)(f) authorizes sheet-metal studs for ceilings and nonstructural partitions, “but not the installation of wood or structural steel for framing.” Ordinary 25-gauge studs and furring channels used as nonstructural ceiling framing stay inside C-4F.
3Under IBC 2018 Section 2211.2, the design and installation of cold-formed steel nonstructural members shall comply with which standard?
A.AISI S240
B.AISC 360
C.AISI S100 only, with no framing standard
D.AISI S220
Explanation: IBC 2018 2211.2 sends nonstructural cold-formed steel light-frame members and connections to AISI S220. AISI S240 is the companion structural-framing standard in 2211.1. AISC 360 is hot-rolled structural steel, not interior drywall studs.
4IBC 2018 Section 2211.1 requires which standard for cold-formed steel structural light-frame systems such as load-bearing walls?
A.AISI S220
B.ASTM C645 only
C.AISI S240
D.GA-216
Explanation: IBC 2018 2211.1 assigns floor, roof, and structural-wall cold-formed steel systems to AISI S240. C-4F work stays on the nonstructural side of that split (S220). ASTM C645 is a product specification historically used for nonstructural members; GA-216 is gypsum application.
5IBC 2018 Section 1607.15 requires interior walls and partitions taller than 6 feet, including finishes, to resist a horizontal load of not less than which value?
A.5 psf
B.15 psf
C.20 psf
D.40 psf
Explanation: IBC 2018 1607.15 sets a minimum 5 psf horizontal load on interior walls and partitions that exceed 6 feet in height. That 5 psf value is also the load used with Table 1604.3 deflection limits and with ASTM C754 limiting-height tables. Do not confuse it with the 15 psf floor live-load allowance for movable partitions in 1607.5.
6Per IBC 2018 Table 1604.3, what is the deflection limit for an interior partition with other brittle finishes (not plaster or stucco)?
A.L/120
B.L/180
C.L/240
D.L/480
Explanation: Table 1604.3 lists interior partitions with other brittle finishes at L/240 under the live-load (horizontal) column. Gypsum board is commonly treated as this brittle-finish case, which is why ASTM C754 L/240 columns are the usual interior-partition check. The table footnote ties the limit to the 1607.15 horizontal load.
7Per IBC 2018 Table 1604.3, an interior partition finished with plaster or stucco is limited to which deflection?
A.L/120
B.L/240
C.L/360
D.L/600
Explanation: Table 1604.3 gives interior partitions with plaster or stucco finishes an L/360 limit. Plaster cracks if the studs flex too much, so the code is stricter than the L/240 brittle or L/120 flexible rows. Select a deeper, thicker, or closer-spaced stud from the ASTM C754 L/360 column.
8IBC 2018 Table 1604.3 allows which deflection for an interior partition that has a flexible finish?
A.L/120
B.L/240
C.L/360
D.No deflection limit applies
Explanation: The flexible-finish row for interior partitions is L/120. That is the most generous of the three partition rows and is the other end of the ASTM C754 L/120–L/240–L/360 set. Flexible, folding, and portable partitions are exempt by table footnote; a built-in metal-stud wall is not.
9IBC 2018 Section 718.2.2 requires fireblocking in concealed stud-wall spaces horizontally at intervals not exceeding what distance?
A.4 feet
B.8 feet
C.10 feet
D.25 feet
Explanation: IBC 2018 718.2.2 requires fireblocking in concealed spaces of stud walls and partitions, including furred spaces and parallel or staggered stud rows, horizontally at intervals not exceeding 10 feet. The same section also requires fireblocking vertically at floor and ceiling levels. Double-stud and chase walls are the usual C-4F places this appears.
10Besides the 10-foot horizontal interval, where else does IBC 2018 Section 718.2.2 require fireblocking in concealed stud-wall spaces?
A.Vertically at the ceiling and floor levels
B.Only at mid-height of every stud
C.Only where electrical boxes occur
D.Only in load-bearing walls
Explanation: Section 718.2.2 item 1 requires fireblocking vertically at the ceiling and floor levels; item 2 is the 10-foot horizontal interval. The rule applies to stud walls and partitions, including nonstructural metal-stud and furred spaces, not only load-bearing walls. Mid-height bridging is a stiffness detail, not a substitute for code fireblocking.

About the NV C-4F Sheet Metal Studs Exam

The Nevada C-4F Sheet Metal Studs Contractor Examination is the official Nevada State Contractors Board trade examination administered by PSI Services LLC. The official exam has 20 scored questions. Passing is 70% (14 of 20 points) in 1 hour. The examination is open book. International Building Code, 2018 (allowed in center). PSI lists USD 95 for one examination portion and USD 140 if taken with CMS; otherwise USD 95 per trade exam (Candidate Information Bulletin 270, updated 3/25/2026). NSCB requires a separate CMS examination for most new applicants, plus a USD 300 application fee and a USD 600 biennial license fee. This English-language MCQ bank is a study aid, not an official PSI form. It does not replace required trade experience, board approval, fingerprints, bonding, or the official examination.

Assessment

Open Book computer-based multiple-choice. International Building Code, 2018 (allowed in center)

Time Limit

1 hour

Passing Score

70% (14 of 20 points)

Exam Fee

USD 95 (PSI Services LLC (for the Nevada State Contractors Board))

NV C-4F Sheet Metal Studs Exam Content Outline

20%

Code Requirements

Code Requirements (4 items)

80%

Metal Framing Installation

Metal Framing Installation (16 items)

How to Pass the NV C-4F Sheet Metal Studs Exam

What You Need to Know

  • Passing score: 70% (14 of 20 points)
  • Assessment: Open Book computer-based multiple-choice. International Building Code, 2018 (allowed in center)
  • Time limit: 1 hour
  • Exam fee: USD 95

Keys to Passing

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

NV C-4F Sheet Metal Studs Study Tips from Top Performers

1Distribute study time to the official bulletin 270 content outline (updated 3/25/2026)
2Use only the PSI-listed references; temporary tabs such as Post-it notes are prohibited
3Confirm NSCB experience documentation before scheduling with PSI
4This bank is an English-language MCQ study aid, not an official PSI form

Frequently Asked Questions

How many questions are on the Nevada C-4F Sheet Metal Studs Contractor Examination?

The official PSI examination has 20 scored questions. Passing is 70% (14 of 20 points) within 1 hour (Candidate Information Bulletin 270, updated 3/25/2026).

How much does the NV C-4F exam cost?

PSI lists USD 95 for one examination portion. Two portions cost USD 140 only if the second portion is CMS. NSCB charges a separate USD 300 application fee and USD 600 biennial license fee.

Is the NV C-4F exam open book?

Yes. PSI lists this examination as open book. International Building Code, 2018 (allowed in center)

Do I still need the CMS examination?

CMS is the required Nevada business-and-law examination. Most new applicants must pass CMS and a trade examination for the requested classification. In most cases you will not retake an exam if you have actively served as a qualified employee in the same classification within the last four years.