All Practice Exams

100+ Free NV C-42 Video Service Networks Practice Questions

Prepare for the Nevada C-42 Constructing, Altering or Improving Video Service Networks Contractor Examination exam with instant access — no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
100+ Questions
100% Free

Loading practice questions...

2026 Statistics

Key Facts: NV C-42 Video Service Networks Exam

35 Q

Official Exam Questions

PSI Nevada Contractor CIB updated 3/25/2026

25 of 35 points

Passing Score

PSI Nevada Contractor CIB updated 3/25/2026

1 hour

Time Allowed

PSI Nevada Contractor CIB updated 3/25/2026

USD 95

PSI Exam Fee (one portion)

PSI Nevada Contractor CIB updated 3/25/2026

Open Book

Book Policy

PSI Nevada Contractor CIB updated 3/25/2026

Nevada C-42 Constructing, Altering or Improving Video Service Networks Contractor Examination is the official NSCB/PSI open book exam: 35 questions, 25 of 35 points, 1 hour, USD 95 (bulletin 270, updated 3/25/2026). Official delivery: English.

Sample NV C-42 Video Service Networks Practice Questions

Try these sample questions to test your NV C-42 Video Service Networks exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Under NAC 624.574, what work may a Nevada C-42 contractor perform?
A.Construct, alter, or improve video service networks
B.Install only interior telephone station wiring
C.Build any electrical service of 600 volts or less
D.Install fire-alarm initiating and notification circuits
Explanation: NAC 624.574 grants the C-42 classification for constructing, altering, or improving video service networks. The PSI C-42 outline and the allowed NEC 2017 reference are written around that video-network scope, not general electrical or fire-alarm work.
2Which 2017 NEC article covers community antenna television and radio distribution systems that use coaxial cable?
A.Article 725
B.Article 800
C.Article 810
D.Article 820
Explanation: NEC 2017 Article 820 is Community Antenna Television and Radio Distribution Systems. It governs listed coaxial CATV cable types, grounding of the outer shield, separation from power, and the 50 ft unlisted-entrance rule. Article 810 covers antennas and lead-ins, not the CATV distribution plant.
3Which 2017 NEC article covers communications circuits such as telephone and similar premises communications wiring?
A.Article 640
B.Article 770
C.Article 800
D.Article 820
Explanation: NEC 2017 Article 800 covers communications circuits, including protectors, grounding, listing, and installation of communications wires and cables. Video-network jobs often share pathways and bonding with Article 800 circuits, so the article still appears on a C-42 open-book exam.
4Which 2017 NEC article covers network-powered broadband communications systems that deliver voice, video, or data through a network interface unit powered from the network?
A.Article 725
B.Article 800
C.Article 830
D.Article 840
Explanation: NEC 2017 Article 830 covers network-powered broadband communications systems. The network, not the premises, supplies power to the network interface unit (NIU). Cable types are the BL (low-power) and BM (medium-power) families.
5A fiber drop ends at an optical network terminal that is powered from a premises outlet rather than from the outside plant. Which 2017 NEC article applies?
A.Article 690
B.Article 800 only
C.Article 830
D.Article 840
Explanation: NEC 2017 Article 840 covers premises-powered broadband communications systems. The optical network terminal (ONT) receives signal on optical fiber and takes its operating power from the premises. Article 840 then points to Articles 770, 800, and 820 for the fiber, communications, and coaxial pieces of the installation.
6Which 2017 NEC article covers optical fiber cables and optical fiber raceways used on a video service network?
A.Article 725
B.Article 760
C.Article 770
D.Article 820
Explanation: NEC 2017 Article 770 covers optical fiber cables and raceways, including Types OFNP, OFNR, OFNG, OFN (nonconductive) and OFCP, OFCR, OFCG, OFC (conductive). Hybrid fiber-coax video plants use Article 770 for the fiber and Article 820 for the coaxial plant.
7Under NEC 2017 90.3, how do Chapter 8 communications articles relate to Chapters 1 through 7?
A.Chapter 8 always amends Chapters 1 through 7 the same way Chapter 3 does
B.Chapter 8 is independent of Chapters 1 through 7 except where a Chapter 8 rule specifically references another Code rule
C.Chapters 1 through 7 never apply to any communications installation
D.Chapter 8 applies only to utilities and is outside the NEC for contractors
Explanation: NEC 2017 90.3 states that Chapter 8 covers communications systems and is independent of Chapters 1 through 7 except where a Chapter 8 requirement specifically references a rule from those chapters. That is why 820.24 can send you to 300.4(D) and 300.11, but a Chapter 3 fill table does not automatically rewrite Article 820.
8NEC 2017 820.15 permits coaxial cable to deliver power to equipment directly associated with the radio-frequency distribution system only if the voltage is not over:
A.30 volts
B.50 volts
C.60 volts
D.120 volts
Explanation: NEC 2017 820.15 allows coaxial cable to power RF-distribution equipment such as amplifiers and line extenders if the voltage is not over 60 volts and the current comes from a transformer or other energy-limiting device. Typical CATV network power is 60 VAC on the hardline.
9What must be done with the accessible portion of abandoned coaxial cable under NEC 2017 820.25?
A.It may remain if it is still in good condition
B.It shall be removed unless it is identified for future use with a tag
C.It shall be cut flush and left in the wall cavity
D.It shall be painted red and left in place as a spare
Explanation: NEC 2017 820.25 requires the accessible portion of abandoned coaxial cables to be removed. Cable that is tagged as identified for future use is not abandoned. Concealed cable inside a finished wall or inside a raceway is not treated as accessible.
10When coaxial cable penetrates a fire-resistance-rated wall, floor, or ceiling, NEC 2017 820.26 requires the opening to be:
A.Left open for cable movement
B.Packed only with fiberglass batt insulation
C.Firestopped using an approved method so the fire-resistance rating is maintained
D.Covered with duct tape on both sides
Explanation: NEC 2017 820.26 (and the parallel 800.26 / 770.26 / 300.21 rules) require installations not to substantially increase the spread of fire or products of combustion. Openings around penetrations of fire-resistance-rated assemblies must be firestopped by approved methods listed for the cable and the assembly.

About the NV C-42 Video Service Networks Exam

The Nevada C-42 Constructing, Altering or Improving Video Service Networks Contractor Examination is the official Nevada State Contractors Board trade examination administered by PSI Services LLC. The official exam has 35 scored questions. Passing is 25 of 35 points in 1 hour. The examination is open book. National Electrical Code, 2017 (allowed in center). PSI lists USD 95 for one examination portion and USD 140 if taken with CMS; otherwise USD 95 per trade exam (Candidate Information Bulletin 270, updated 3/25/2026). NSCB requires a separate CMS examination for most new applicants, plus a USD 300 application fee and a USD 600 biennial license fee. This English-language MCQ bank is a study aid, not an official PSI form. It does not replace required trade experience, board approval, fingerprints, bonding, or the official examination.

Assessment

Open Book computer-based multiple-choice. National Electrical Code, 2017 (allowed in center)

Time Limit

1 hour

Passing Score

25 of 35 points

Exam Fee

USD 95 (PSI Services LLC (for the Nevada State Contractors Board))

NV C-42 Video Service Networks Exam Content Outline

29%

NEC

NEC (10 items)

6%

NESC

NESC (2 items)

66%

Cable-General

Cable-General (23 items)

How to Pass the NV C-42 Video Service Networks Exam

What You Need to Know

  • Passing score: 25 of 35 points
  • Assessment: Open Book computer-based multiple-choice. National Electrical Code, 2017 (allowed in center)
  • Time limit: 1 hour
  • Exam fee: USD 95

Keys to Passing

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

NV C-42 Video Service Networks Study Tips from Top Performers

1Distribute study time to the official bulletin 270 content outline (updated 3/25/2026)
2Use only the PSI-listed references; temporary tabs such as Post-it notes are prohibited
3Confirm NSCB experience documentation before scheduling with PSI
4This bank is an English-language MCQ study aid, not an official PSI form

Frequently Asked Questions

How many questions are on the Nevada C-42 Constructing, Altering or Improving Video Service Networks Contractor Examination?

The official PSI examination has 35 scored questions. Passing is 25 of 35 points within 1 hour (Candidate Information Bulletin 270, updated 3/25/2026).

How much does the NV C-42 exam cost?

PSI lists USD 95 for one examination portion. Two portions cost USD 140 only if the second portion is CMS. NSCB charges a separate USD 300 application fee and USD 600 biennial license fee.

Is the NV C-42 exam open book?

Yes. PSI lists this examination as open book. National Electrical Code, 2017 (allowed in center)

Do I still need the CMS examination?

CMS is the required Nevada business-and-law examination. Most new applicants must pass CMS and a trade examination for the requested classification. In most cases you will not retake an exam if you have actively served as a qualified employee in the same classification within the last four years.