100+ Free NV Automatic Fire Sprinklers Practice Questions
Prepare for the Nevada C-41A Automatic Fire Sprinklers Contractor Examination exam with instant access — no signup required.
Loading practice questions...
Explore More Nevada NSCB Contractor Examinations
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
Key Facts: NV Automatic Fire Sprinklers Exam
45 Q
Official Exam Questions
PSI Nevada Contractor CIB updated 3/25/2026
32 of 45 points
Passing Score
PSI Nevada Contractor CIB updated 3/25/2026
1.5 hours
Time Allowed
PSI Nevada Contractor CIB updated 3/25/2026
USD 95
PSI Exam Fee (one portion)
PSI Nevada Contractor CIB updated 3/25/2026
Open Book
Book Policy
PSI Nevada Contractor CIB updated 3/25/2026
Nevada C-41A Automatic Fire Sprinklers Contractor Examination is the official NSCB/PSI open book exam: 45 questions, 32 of 45 points, 1.5 hours, USD 95 (bulletin 270, updated 3/25/2026). Official delivery: English.
Sample NV Automatic Fire Sprinklers Practice Questions
Try these sample questions to test your NV Automatic Fire Sprinklers exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.
1Under NAC 624.572, which water-based assemblies may a Nevada C-41A Automatic Fire Sprinklers contractor fabricate, install, alter, repair, and service?
2In a deluge sprinkler system under NFPA 13 (2007), what is in the piping and how do the sprinklers operate?
3Per NFPA 13 (2007) Table 6.2.5.1, what temperature classification and maximum ceiling temperature apply to sprinklers rated 175°F to 225°F?
4A standard spray sprinkler has a blue frame and is rated 286°F. Which NFPA 13 (2007) temperature classification is that?
5When a gravity tank is the automatic water supply for a sprinkler system, what produces the working pressure at the base of the riser?
6How does NFPA 13 (2007) require a pressure tank used as an automatic sprinkler water supply to be proportioned?
7What kind of valve does NFPA 13 (2007) require for controlling a sprinkler system water supply?
8Where is the inspector's test connection placed on a wet-pipe sprinkler system, and what orifice does it use?
9When is a wet-pipe sprinkler system the preferred automatic arrangement under NFPA 13 (2007)?
10Per NFPA 13 (2007) 6.9, when must a local waterflow alarm be provided on a sprinkler system?
About the NV Automatic Fire Sprinklers Exam
The Nevada C-41A Automatic Fire Sprinklers Contractor Examination is the official Nevada State Contractors Board trade examination administered by PSI Services LLC. The official exam has 45 scored questions. Passing is 32 of 45 points in 1.5 hours. The examination is open book. NFPA 13 (2007), NFPA 14 (2007), NFPA 24 (2010), and NFPA 25 (2008) (allowed in center). PSI lists USD 95 for one examination portion and USD 140 if taken with CMS; otherwise USD 95 per trade exam (Candidate Information Bulletin 270, updated 3/25/2026). NSCB requires a separate CMS examination for most new applicants, plus a USD 300 application fee and a USD 600 biennial license fee. This English-language MCQ bank is a study aid, not an official PSI form. It does not replace required trade experience, board approval, fingerprints, bonding, or the official examination.
Assessment
Open Book computer-based multiple-choice. NFPA 13 (2007), NFPA 14 (2007), NFPA 24 (2010), and NFPA 25 (2008) (allowed in center)
Time Limit
1.5 hours
Passing Score
32 of 45 points
Exam Fee
USD 95 (PSI Services LLC (for the Nevada State Contractors Board))
NV Automatic Fire Sprinklers Exam Content Outline
Sprinkler Systems
Sprinkler Systems (16 items)
Standpipe Systems
Standpipe Systems (16 items)
Inspection, Testing and Maintenance
Inspection, Testing and Maintenance (8 items)
General Regulations
General Regulations (5 items)
How to Pass the NV Automatic Fire Sprinklers Exam
What You Need to Know
- Passing score: 32 of 45 points
- Assessment: Open Book computer-based multiple-choice. NFPA 13 (2007), NFPA 14 (2007), NFPA 24 (2010), and NFPA 25 (2008) (allowed in center)
- Time limit: 1.5 hours
- Exam fee: USD 95
Keys to Passing
- Work through all 100 available questions
- Review every answer and explanation
- Track weak areas and revisit them
- Use our AI tutor for tough concepts
NV Automatic Fire Sprinklers Study Tips from Top Performers
Frequently Asked Questions
How many questions are on the Nevada C-41A Automatic Fire Sprinklers Contractor Examination?
The official PSI examination has 45 scored questions. Passing is 32 of 45 points within 1.5 hours (Candidate Information Bulletin 270, updated 3/25/2026).
How much does the NV C-41A exam cost?
PSI lists USD 95 for one examination portion. Two portions cost USD 140 only if the second portion is CMS. NSCB charges a separate USD 300 application fee and USD 600 biennial license fee.
Is the NV C-41A exam open book?
Yes. PSI lists this examination as open book. NFPA 13 (2007), NFPA 14 (2007), NFPA 24 (2010), and NFPA 25 (2008) (allowed in center)
Do I still need the CMS examination?
CMS is the required Nevada business-and-law examination. Most new applicants must pass CMS and a trade examination for the requested classification. In most cases you will not retake an exam if you have actively served as a qualified employee in the same classification within the last four years.