100+ Free NM CID EE-98 Practice Questions
Prepare for the New Mexico CID EE-98 Residential and Commercial Electrical Contractor Examination exam with instant access — no signup required.
Loading practice questions...
Explore More New Mexico CID Contractor and Inspector Examinations
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
Key Facts: NM CID EE-98 Exam
170 Q
Official Combined Questions
PSI NM Contractor Bulletin 4/3/2026
75%
Passing Score Per Part
PSI NM Contractor Bulletin 4/3/2026
USD 269.06
Combination Exam Fee
PSI NM Contractor Bulletin 4/3/2026
3 parts
Official Exam Structure
PSI NM Contractor Bulletin 4/3/2026
NM CID EE-98 is a three-part PSI combination exam totaling 170 questions (80+40+50), 75% per part, USD 269.06 (bulletin 4/3/2026).
Sample NM CID EE-98 Practice Questions
Try these sample questions to test your NM CID EE-98 exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.
1On a New Mexico commercial and industrial EE-98 Part 1 installation, what is the minimum depth of working space in front of a 208Y/120-volt switchboard where exposed live parts are on one side and no live or grounded parts are on the other side (Condition 1)?
2Per NEC Article 100, which conductors are classified as a feeder?
3What dedicated equipment space is required above a floor-mounted 480-volt switchboard, other than the structural ceiling, in a commercial electrical room?
4Except as permitted by the exceptions in NEC 110.26(A)(3), what is the minimum headroom of working space about service equipment, switchboards, switchgear, panelboards, or motor control centers?
5At a service supplying a commercial occupancy, where must the available fault current and the date the calculation was performed be field marked?
6What is the minimum width of the working space in front of a 36-inch-wide commercial panelboard?
7How must a grounded (neutral) conductor 6 AWG or smaller generally be identified?
8Unless the equipment is listed and marked otherwise, conductor ampacity used at terminations rated 100 amperes or less, or marked for 14 AWG through 1 AWG conductors, shall be selected from which temperature column of Table 310.16?
9What is the minimum vertical clearance above a public street, alley, road, or parking area subject to truck traffic for 120/240-volt overhead service-drop conductors?
10A commercial feeder supplies an 80-ampere continuous load and a 40-ampere noncontinuous load. What is the minimum conductor ampacity required by NEC 215.2(A)(1) before any adjustment or correction factors?
About the NM CID EE-98 Exam
The New Mexico CID EE-98 examination is the official three-part PSI combination exam for the residential and commercial electrical contractor classification. Part 1 covers commercial and industrial electrical work (80 questions, 200 minutes), Part 2 covers residential electrical work (40 questions, 100 minutes), and Part 3 covers specialties including low voltage, signs, cathodic and lightning protection, telephone/computer systems, and sound/communication (50 questions, 135 minutes). Each part requires 75%. The combination fee is USD 269.06 (bulletin updated 4/3/2026). This English-language MCQ bank is a study aid for the combined EE-98 identity; it is not an official PSI form and does not replace required experience, code-book navigation, the Business and Law requirement, or the official three-part examination.
Assessment
Three-part combination examination. Candidates must pass all parts. Retake only the failed part(s).
Time Limit
435 minutes across three parts (200 + 100 + 135)
Passing Score
75% on each part (60/80, 30/40, and 38/50 points)
Exam Fee
USD 269.06 combination; USD 89.69 per part retake (PSI Services LLC (for New Mexico Construction Industries Division))
NM CID EE-98 Exam Content Outline
Part 1 Commercial and Industrial
Commercial/industrial services, feeders, grounding, hazardous locations, motors, and NM electrical code (80 official items)
Part 2 Residential
Residential services, branch circuits, pools, lighting, and NM electrical code (40 official items)
Part 3 Specialties
Low voltage/alarms, signs, cathodic/lightning protection, telephone/computer, and sound/communication (50 official items)
How to Pass the NM CID EE-98 Exam
What You Need to Know
- Passing score: 75% on each part (60/80, 30/40, and 38/50 points)
- Assessment: Three-part combination examination. Candidates must pass all parts. Retake only the failed part(s).
- Time limit: 435 minutes across three parts (200 + 100 + 135)
- Exam fee: USD 269.06 combination; USD 89.69 per part retake
Keys to Passing
- Work through all 100 available questions
- Review every answer and explanation
- Track weak areas and revisit them
- Use our AI tutor for tough concepts
NM CID EE-98 Study Tips from Top Performers
Frequently Asked Questions
How is the EE-98 exam structured?
PSI administers EE-98 as one three-part combination: Part 1 Commercial and Industrial (80 questions, 200 minutes), Part 2 Residential (40 questions, 100 minutes), and Part 3 Specialties (50 questions, 135 minutes). You must pass all parts. Retake only failed parts at USD 89.69 each.
What is the passing score?
75% on each part: 60 of 80, 30 of 40, and 38 of 50 points (bulletin updated 4/3/2026).