Key Facts: AZ ROC R-16 Fire Protection Exam

50 Questions

Official Question Count

PSI R-16 content outline

120 Minutes

Time Limit

PSI R-16 content outline

70%

Passing Score

PSI R-16 content outline

Sprinkler Systems, 21 items

Largest Subject Area

PSI R-16 content outline

$66

Trade Exam Fee

roc.az.gov/licensing-fees

$61

Statutes and Rules Exam Fee

roc.az.gov/licensing-fees

The Arizona ROC R-16 Fire Protection Systems (Residential) Examination is 50 scored multiple-choice questions in 120 minutes, open book, at a 70% passing score with a $66 PSI exam fee. This free bank is an English-language multiple-choice study aid weighted to the official PSI subject areas; it is not the official exam and does not reproduce PSI items.

Sample AZ ROC R-16 Fire Protection Practice Questions

Try these sample questions to test your AZ ROC R-16 Fire Protection exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1What is the primary purpose of an NFPA 13D residential fire sprinkler system?
A.To completely extinguish any fire regardless of size before fire department arrival
B.To prevent flashover in the room of origin and provide improved chance for occupant egress
C.To protect the structural frame of the building for a minimum of 4 hours
D.To replace the requirement for smoke alarms in all residential bedrooms
Explanation: NFPA 13D (Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes) is specifically designed as a life safety system. Its primary purpose is to prevent flashover in the room of origin and allow occupants sufficient time to evacuate the dwelling safely.
2Per NFPA 13D, what is the minimum design discharge density required over the coverage area for a residential sprinkler?
A.0.02 gpm/sq ft
B.0.05 gpm/sq ft
C.0.10 gpm/sq ft
D.0.15 gpm/sq ft
Explanation: NFPA 13D specifies a minimum design density of 0.05 gpm/sq ft over the design area, or the listed discharge density of the specific residential sprinkler head, whichever is greater.
3What is the minimum operating flow rate required for a single operating residential sprinkler head in an NFPA 13D design area, unless listed for a different rate?
A.8 gpm
B.13 gpm
C.18 gpm
D.26 gpm
Explanation: NFPA 13D mandates that the minimum operating flow rate for a single sprinkler head in the design area is 18 gpm, or the manufacturer's listed flow rate for that specific head and coverage area, whichever is greater.
4When two residential sprinklers operate simultaneously in an NFPA 13D design compartment, what is the minimum required flow rate per sprinkler head?
A.9 gpm
B.13 gpm
C.18 gpm
D.22 gpm
Explanation: Under NFPA 13D, when multiple sprinklers (up to the maximum 2-head design area) operate simultaneously, each sprinkler must discharge at least 13 gpm, or its listed flow rate for multiple sprinkler operation, whichever is greater.
5What is the minimum required water supply duration for an NFPA 13D system installed in a one- or two-family detached dwelling?
A.7 minutes
B.10 minutes
C.15 minutes
D.30 minutes
Explanation: NFPA 13D requires a minimum water supply duration of 10 minutes for standard one- and two-family detached dwellings.
6According to NFPA 13D, what is the minimum water supply duration required for a sprinkler system protecting a manufactured home?
A.5 minutes
B.7 minutes
C.10 minutes
D.20 minutes
Explanation: NFPA 13D allows a reduced water supply duration of 7 minutes for manufactured homes, recognizing their specific construction size and loading characteristics.
7Under NFPA 13D, sprinklers may be omitted from small residential clothes closets provided the closet area does not exceed what maximum size and meets wall surface criteria?
A.12 sq ft
B.24 sq ft
C.36 sq ft
D.55 sq ft
Explanation: NFPA 13D permits omitting sprinklers from clothes closets, linen closets, and pantries where the area does not exceed 24 sq ft, the shortest dimension does not exceed 3 ft, and the walls and ceiling are surfaced with noncombustible or limited-combustible materials.
8What is the maximum floor area of a residential bathroom that permits omitting fire sprinkler protection under NFPA 13D?
A.24 sq ft
B.40 sq ft
C.55 sq ft
D.70 sq ft
Explanation: NFPA 13D allows sprinklers to be omitted from bathrooms that have an area not exceeding 55 sq ft, provided the walls and plumbing fixtures do not present an unusual fire hazard.
9What color is the liquid bulb element in an ordinary temperature-rated (135°F to 170°F) sprinkler head?
A.Orange or Red
B.Yellow or Green
C.Blue
D.Purple
Explanation: Glass bulb sprinkler heads rated for Ordinary temperature classification (135°F to 170°F) contain liquid color-coded Orange (for 135°F/140°F) or Red (for 155°F/160°F/170°F).
10What is the operating temperature range for an intermediate temperature-rated sprinkler head with a yellow bulb?
A.135°F to 170°F
B.175°F to 225°F
C.250°F to 300°F
D.325°F to 375°F
Explanation: Intermediate temperature-rated sprinklers operate between 175°F and 225°F. A yellow glass bulb specifically denotes a 175°F rating, while green denotes 200°F/220°F.

About the AZ ROC R-16 Fire Protection Exam

The Arizona ROC R-16 Fire Protection Systems (Residential) Examination is the open-book, computer-delivered PSI trade exam for the Arizona Registrar of Contractors R-16 classification, whose scope is the installation and repair of fire prevention and fire protection systems including mechanical apparatus, devices, piping, low voltage signaling systems and related equipment; all other electrical work must be subcontracted to a properly licensed contractor. The official outline runs 50 scored questions in 120 minutes at a 70% passing score, weighted heavily toward sprinkler systems, water supply and distribution, and heat and smoke detectors. It is a distinct, shorter exam from the 75-question commercial C-16/CR-16 examination.

Assessment

One 50-question open-book multiple-choice trade examination, 120 minutes, 70% to pass, across six subject areas: Sprinkler Systems 21, Water Supply and Distribution 10, Heat and Smoke Detectors 8, Backflow Prevention 5, Firepumps and Standpipes 3, and Testing and Inspection 3.

Time Limit

120 minutes

Passing Score

70%

Exam Fee

$66 (Arizona ROC / PSI Services LLC)

AZ ROC R-16 Fire Protection Exam Content Outline

42%

Sprinkler Systems

Residential sprinkler selection and placement, coverage areas and spacing, deflector distances, obstruction rules, temperature ratings and response, omitted spaces, and hydraulic design per NFPA 13/13D.

20%

Water Supply and Distribution

Static/residual pressure and flow tests, meters and service sizing, hydraulic calculations and friction loss, stored-water tanks and booster pumps, and combined domestic/fire supplies.

16%

Heat and Smoke Detectors

NFPA 72 household smoke and heat detector spacing and location, interconnection and power supply, carbon monoxide alarms, and low-voltage signaling wiring within the R-16 scope.

10%

Backflow Prevention

Cross-connection control on fire lines, DCVA and RPZ selection and pressure loss, forward-flow testing, and Arizona annual certified-tester requirements.

6%

Firepumps and Standpipes

Fire pump types, drivers, controllers and churn conditions, pressure relief, and NFPA 14 standpipe classes, hose connections and pressures.

6%

Testing and Inspection

Hydrostatic acceptance testing, main drain tests, waterflow and tamper switches, NFPA 25 inspection frequencies, and spare-sprinkler requirements.

How to Pass the AZ ROC R-16 Fire Protection Exam

What You Need to Know

  • Passing score: 70%
  • Assessment: One 50-question open-book multiple-choice trade examination, 120 minutes, 70% to pass, across six subject areas: Sprinkler Systems 21, Water Supply and Distribution 10, Heat and Smoke Detectors 8, Backflow Prevention 5, Firepumps and Standpipes 3, and Testing and Inspection 3.
  • Time limit: 120 minutes
  • Exam fee: $66

Keys to Passing

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

AZ ROC R-16 Fire Protection Study Tips from Top Performers

1Sprinkler Systems alone is 21 of 50 items - master residential sprinkler spacing, deflector distances, obstruction rules and omitted spaces first.
2Heat and Smoke Detectors is 8 of 50 items and is scored against NFPA 72 (2016). Do not skip it; it is the second-largest single-topic block after sprinklers and water supply.
3Work hydraulic basics until they are automatic: Q = K x sqrt(P), 0.433 psi per foot of elevation, and Hazen-Williams C values (150 plastic and copper, 120 wet steel).
4PSI lists NFPA 13 (2016) rather than 13D in the R-16 reference list, and the 2018 IRC Section P2904 is also allowed - check both when a residential sprinkler number is in dispute.
5Backflow Prevention is 5 items; know DCVA versus RPZ selection, their pressure losses, and Arizona's annual certified-tester requirement.

Frequently Asked Questions

How many questions are on the Arizona ROC R-16 exam?

The PSI R-16 Fire Protection Systems (Residential) content outline lists 50 scored multiple-choice questions with 120 minutes of testing time.

How is R-16 different from C-16 or CR-16?

R-16 is the residential classification and is a 50-question, 120-minute exam. The commercial C-16/CR-16 exam is 75 questions in 180 minutes and adds clean agent, foam, dry and wet chemical, carbon dioxide, portable extinguisher and commercial kitchen areas that R-16 does not cover.

What is the passing score for the R-16 exam?

70%, which is 35 correct out of the 50 scored questions. The Arizona Statutes and Rules Exam is a separate requirement.

Which references may I bring to the R-16 exam?

PSI's R-16 reference list includes NFPA 10, 11, 12, 12A, 13 (2016), 14, 17, 17A, 24, 25, 72 (2016), 96 and 2001, plus the 2018 IPC, 2018 IRC and 2015 Uniform Plumbing Code, bound and tabbed with permanent tabs only.

Does R-16 cover fire alarm work?

Partly. Heat and Smoke Detectors is 8 of the 50 items, and the R-16 scope includes low voltage signaling systems; other electrical devices, apparatus and wiring must be subcontracted to a properly licensed contractor.