100+ Free Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building Examination Practice Questions
Prepare for the Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building Examination exam with instant access — no signup required.
Loading practice questions...
Explore More Arizona Registrar of Contractors Trade Examinations
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
Key Facts: Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building Examination Exam
AZ ROC B-1/B-2/KB-1/KB-2
Exam Code / Label
Arizona Registrar of Contractors / PSI
100 Questions
Official Question Count
PSI Candidate Information Bulletin
240 Minutes (4 Hours)
Time Limit
PSI Candidate Information Bulletin
70% (70 / 100)
Passing Score
PSI Candidate Information Bulletin
$66
Exam Fee
PSI Candidate Information Bulletin
Open-Book Computer Test
Exam Format
PSI Testing Services
NASCLA Accredited Commercial Building Exam
Alternative Waiver
Arizona Registrar of Contractors
Prepare for the 2026 Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building trade examination with 100 realistic practice questions matching the official PSI blueprint. The official open-book exam comprises 100 scored questions, a 240-minute (4-hour) time limit, and a 70% passing score ($66 exam fee administered by PSI). This practice question bank is an English-language MCQ study adaptation covering sitework, concrete, masonry, structural steel, wood framing, roofing, doors/windows, finishes, OSHA safety, and IBC/IRC building codes.
Sample Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building Examination Practice Questions
Try these sample questions to test your Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building Examination exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.
1Under OSHA 29 CFR 1926 Subpart P, what is the maximum unconfined compressive strength threshold for cohesive soil to be classified as Type A soil?
2A soil sample tested using the Modified Proctor Test (ASTM D1557) achieves a maximum dry density of 124.0 pcf at an optimum moisture content of 11.5%. During field quality control testing, a nuclear density gauge measures a wet density of 134.4 pcf at a moisture content of 12.0%. What is the relative compaction percentage, and does it satisfy a specification requiring 95% Modified Proctor density?
3A contractor must excavate a trench measuring 400 feet long, 6 feet wide, and 8 feet deep. If the undisturbed soil in bank cubic yards (BCY) has a swell factor of 25% when excavated into loose cubic yards (LCY), how many loose cubic yards of material must be hauled away by dump trucks?
4According to IBC Section 1804.4, what is the minimum required slope away from a building foundation wall for unpaved ground surface, and over what minimum distance must it be maintained?
5Per IBC Table 1806.2 (Presumptive Load-Bearing Values), what is the official default presumptive allowable foundation pressure for sandy gravel and/or gravel soils in the absence of a site-specific geotechnical report?
6When installing a subterranean French drain system around a foundation perimeter to intercept high groundwater, what is the primary function of wrapping the aggregate pocket with a non-woven geotextile filter fabric?
7In segmental retaining wall (SRW) design, what is the standard recommended minimum geogrid reinforcement embedment length expressed as a ratio of total wall height (H) for typical soil and surcharge conditions?
8To prevent severe hydrostatic pressure accumulation behind a cast-in-place concrete retaining wall, which drainage detail must be incorporated near the base of the wall?
9A structural steel column delivers an ultimate dead plus live design load of 180,000 pounds (180 kips) to a square concrete spread footing resting on soil with an allowable bearing capacity of 3,000 psf. What is the minimum required side length of the square spread footing?
10A continuous concrete grade beam footing measures 300 feet long, 24 inches wide, and 12 inches deep. Allowing a 10% waste factor for ground irregularities, how many cubic yards of ready-mix concrete should be ordered?
About the Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building Examination Exam
The Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building Examination is the combined trade assessment administered by PSI Services LLC for candidates seeking licensure under four primary contractor classifications in Arizona: B-1 General Commercial Contractor, B-2 General Small Commercial Contractor, KB-1 Dual Building Contractor, and KB-2 Dual Residential and Commercial Contractor. The examination consists of 100 computer-delivered, open-book multiple-choice questions with a 240-minute (4-hour) time limit and a required passing threshold of 70% (70 correct answers). Test items evaluate technical proficiency across sitework, excavation, structural concrete, reinforced masonry, structural steel and cold-formed metals, rough and finish carpentry, thermal and moisture protection, doors and windows, interior finishes, OSHA construction safety regulations (29 CFR 1926), and International Building Code (IBC) / International Residential Code (IRC) compliance. Candidates may also submit passing scores from the NASCLA Accredited Examination for Commercial General Building Contractors in lieu of taking this trade examination. Note: Local practice questions serve as an English-language MCQ study adaptation and do not replace official code references, board approval, or hands-on trade experience.
Questions
100 scored questions
Time Limit
240 minutes
Passing Score
70%
Exam Fee
$66 (Arizona Registrar of Contractors / PSI Services LLC)
Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building Examination Exam Content Outline
Sitework
Soil classification (USCS & OSHA Type A/B/C), excavation cut/fill volume calculations, soil compaction testing (Proctor tests), site grading, slope drainage, subterranean drainage, retaining wall backfill, and load-bearing capacity of soils per IBC Chapter 18.
Concrete
Concrete mix design, water-cementitious ratio, slump testing (ASTM C143), air content, volumetric calculations, curing methods (ACI 308), formwork design (ACI 347), rebar sizing/spacing/cover (ACI 318), control joint spacing, and post-tensioned slab installation.
Masonry
Concrete Masonry Units (CMU) nominal vs actual sizing, mortar types per ASTM C270 (Type M, S, N, O), grouting lifts/slump (ASTM C476), vertical/horizontal reinforcement, bond beams, control joints, brick veneer flashing, weep holes, and cold weather masonry rules.
Metals
Structural steel shapes (W, C, L, HSS), AISC bolted/welded connection specifications, AWS D1.1 structural welding, open-web steel joists (SJI K/LH/DLH series), joist bridging and stability, metal deck installation (SDI), cold-formed light-gauge steel framing (AISI), and OSHA steel erection safety (Subpart R).
Carpentry
Lumber grading, structural engineered wood (LVL, Glulam, I-joists), floor/wall/roof rough framing layout, header sizing, load-bearing wood stud walls, prefabricated roof truss installation/bracing (ANSI/TPI 1), structural panel sheathing (plywood/OSB), APA span ratings, and fastener schedules per IBC Chapter 23 / IRC Chapter 6.
Thermal and Moisture Protection
Thermal insulation types and R-value/U-factor calculations (IECC), vapor retarders, air barriers, steep and low-slope roofing systems (BUR, modified bitumen, TPO/EPDM single-ply, asphalt shingles, tile per NRCA), flashing details (SMACNA), stucco 3-coat plaster systems, and foundation waterproofing/dampproofing per IBC Chapter 18.
Doors and Windows
Fire-rated door assemblies (NFPA 80), emergency egress doors, panic hardware, clear opening dimensions, safety glazing hazardous locations (tempered/laminated per IBC Chapter 24), window pan flashing, NFRC thermal performance ratings, and storefront/curtain wall framing.
Finishes
Gypsum board installation and finishing (GA-216, Levels 0-5), Type X fire-rated drywall, acoustical suspended ceiling systems (ASTM C635/C636, seismic wires), ceramic tile installation (TCNA/ANSI A108), floor moisture testing (ASTM F1869/F2170), and interior finish flame spread/smoke development index (ASTM E84).
Safety
OSHA 29 CFR 1926 standards: Fall protection systems and trigger heights (Subpart M), excavation/trenching soil sloping and trench box requirements (Subpart P), scaffolding assembly and loading (Subpart L), extension/step ladder safety (Subpart X), Hazard Communication SDS (GHS), respirable crystalline silica standards (1926.1153), GFCI temporary power protection (Subpart K), and crane clearance/rigging safety (Subpart CC).
General Building Code
IBC Chapter 3 occupancy classifications (Assembly, Business, Educational, Factory, Hazardous, Institutional, Mercantile, Residential, Storage), Chapter 6 construction types (Types I-V), Chapter 5 height and area limitations and sprinkler increases, Chapter 10 means of egress calculations (occupant load, egress width, exit counts, exit separation distance), and ADA accessibility requirements (ICC A117.1).
How to Pass the Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building Examination Exam
What You Need to Know
- Passing score: 70%
- Exam length: 100 questions
- Time limit: 240 minutes
- Exam fee: $66
Keys to Passing
- Work through all 100 available questions
- Review every answer and explanation
- Track weak areas and revisit them
- Use our AI tutor for tough concepts
Arizona ROC B-1/B-2/KB-1/KB-2 Residential and Commercial Building Examination Study Tips from Top Performers
Frequently Asked Questions
Which contractor licenses in Arizona are covered by this single trade exam?
This single combined exam covers four Arizona Registrar of Contractors (AZ ROC) building license classifications: B-1 General Commercial Contractor, B-2 General Small Commercial Contractor, KB-1 Dual Building Contractor, and KB-2 Dual Residential and Commercial Contractor.
What is the format, time limit, and passing score of the AZ ROC B-1/B-2/KB-1/KB-2 exam?
The exam is a computer-delivered, open-book test administered by PSI Services LLC. It consists of 100 multiple-choice questions. Candidates are given 240 minutes (4 hours) to complete the exam, and a score of 70% or higher (70 correct out of 100) is required to pass.
Is the NASCLA Commercial General Building Exam accepted in lieu of this trade exam?
Yes. Arizona ROC accepts a passing score on the NASCLA Accredited Examination for Commercial General Building Contractors in lieu of taking the AZ ROC B-1/B-2/KB-1/KB-2 trade examination.
Can I bring code books into the PSI testing center?
Yes. The exam is open-book. Candidates may bring approved bound reference books (such as the IBC, IRC, OSHA 1926, ACI standards, and trade reference manuals) into the PSI testing center, provided they are permanently bound and marked according to PSI guidelines (tabs must be permanent index tabs, no loose notes).
Do candidates still need to pass the Arizona Statutes and Rules exam?
Yes. In addition to passing this trade examination (or holding an approved NASCLA waiver), candidates must pass the Arizona Management and Business Exam (Solar / Business Law SMM exam) and fulfill all ROC licensure experience and background check criteria.