According to the NEC, what is the definition of a 'branch circuit'?

A
B
C
D
to track
2026 Statistics

Key Facts: RI Electrician Exam

70%

Passing Score

RI Electricians' Board

~80

Exam Questions

RI Board

4 hrs

Time Limit

RI Board

$50-$75

Exam Fee

RI Board

The RI Journeyman Electrician exam requires 70% to pass across approximately 80 multiple-choice questions in 4 hours. Rhode Island uniquely administers this exam through the state board rather than a third-party provider like PSI. The exam is based on the 2020 NEC, and the fee is $50-$75. A bound copy of the NEC is permitted during the exam.

Sample RI Electrician Practice Questions

Try these sample questions to test your RI Electrician exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1According to the NEC, what is the definition of a 'branch circuit'?
A.The circuit conductors between the service point and the main disconnecting means
B.The circuit conductors between the final overcurrent device protecting the circuit and the outlet(s)
C.Any circuit that supplies power to a motor
D.The conductors between the transformer and the first overcurrent device
Explanation: Per NEC Article 100, a branch circuit is defined as the circuit conductors between the final overcurrent device protecting the circuit and the outlet(s). This definition is fundamental to understanding how the NEC organizes and regulates different parts of an electrical system.
2In Rhode Island, the Electricians' Examination & Licensing Board oversees journeyman electrician licensing. What is the NEC edition currently adopted by Rhode Island?
A.NEC 2017
B.NEC 2020
C.NEC 2023
D.NEC 2026
Explanation: Rhode Island currently uses the 2020 NEC edition. The RI Electricians' Examination & Licensing Board administers the exam directly (state-administered, not PSI). Rhode Island typically adopts NEC editions on a delayed cycle compared to some states.
3Per NEC 210.8(A), GFCI protection is required for all 125-volt through 250-volt receptacles in which of the following dwelling unit locations?
A.Living rooms
B.Bedrooms
C.Kitchens
D.Closets
Explanation: NEC 210.8(A) requires GFCI protection for 125-volt through 250-volt receptacles in dwelling unit kitchens, along with bathrooms, garages, outdoors, crawl spaces, basements, and other specified locations. The 2023 NEC expanded GFCI requirements significantly.
4What is the minimum size equipment grounding conductor required for a 60-ampere circuit per NEC Table 250.122?
A.14 AWG copper
B.12 AWG copper
C.10 AWG copper
D.8 AWG copper
Explanation: Per NEC Table 250.122, a 60-ampere overcurrent device requires a minimum 10 AWG copper equipment grounding conductor. This table is based on the rating of the overcurrent device protecting the circuit, not the conductor ampacity.
5According to NEC 250.66, what is the minimum size grounding electrode conductor for a 2/0 AWG copper service conductor?
A.8 AWG copper
B.6 AWG copper
C.4 AWG copper
D.2 AWG copper
Explanation: Per NEC Table 250.66, for service conductors sized 2/0 AWG copper (or 4/0 AWG aluminum), the minimum grounding electrode conductor is 4 AWG copper or 2 AWG aluminum. This table correlates the size of the largest service-entrance conductor with the required grounding electrode conductor.
6What is the standard voltage drop recommendation for branch circuits per NEC 210.19(A) Informational Note No. 4?
A.2%
B.3%
C.5%
D.8%
Explanation: NEC 210.19(A) Informational Note No. 4 recommends that voltage drop on branch circuits should not exceed 3%, and the total voltage drop for feeders and branch circuits combined should not exceed 5%. While these are recommendations rather than requirements, they represent good practice.
7Per NEC Table 310.16, what is the ampacity of a 6 AWG THWN-2 copper conductor at 75°C column?
A.40 amperes
B.55 amperes
C.65 amperes
D.75 amperes
Explanation: Per NEC Table 310.16, a 6 AWG copper conductor with a 75°C insulation rating (such as THWN-2 used at 75°C) has an ampacity of 65 amperes. THWN-2 is rated for 90°C but is commonly used at the 75°C column when terminated at equipment rated for 75°C.
8According to NEC 314.16(B), what is the volume allowance for each 12 AWG conductor in a box fill calculation?
A.2.00 cubic inches
B.2.25 cubic inches
C.2.50 cubic inches
D.3.00 cubic inches
Explanation: Per NEC Table 314.16(B), each 12 AWG conductor requires a volume allowance of 2.25 cubic inches in a box fill calculation. This includes equipment grounding conductors counted as one conductor, device yokes counted as two conductors, and clamps counted as one conductor.
9Per NEC 430.52, what is the maximum size dual-element time-delay fuse permitted for motor branch-circuit short-circuit and ground-fault protection for a standard AC motor?
A.125% of motor FLC
B.150% of motor FLC
C.175% of motor FLC
D.250% of motor FLC
Explanation: Per NEC Table 430.52, the maximum rating for a dual-element time-delay fuse used for motor branch-circuit short-circuit and ground-fault protection is 175% of the motor's full-load current. If 175% does not correspond to a standard fuse size, the next higher standard size may be used.
10What is the minimum height above grade for service drop conductors over a residential driveway?
A.10 feet
B.12 feet
C.15 feet
D.18 feet
Explanation: Per NEC 230.24(B)(1), service drop conductors must maintain a minimum clearance of 12 feet above residential driveways and commercial areas not subject to truck traffic. This clearance ensures safe passage of vehicles beneath the conductors.

About the RI Electrician Exam

The Rhode Island Journeyman Electrician exam is administered directly by the RI Electricians' Examination & Licensing Board (not through PSI). Based on the 2020 NEC, it covers electrical theory, code compliance, grounding and bonding, wiring methods, load calculations, motors, transformers, and special occupancies.

Questions

80 scored questions

Time Limit

4 hours

Passing Score

70%

Exam Fee

$50-$75 (RI Electricians' Examination & Licensing Board)

RI Electrician Exam Content Outline

20%

NEC General & Theory

Definitions, electrical theory, NEC navigation, working space requirements, and installation fundamentals

20%

Branch Circuits & Overcurrent Protection

Circuit sizing, receptacle spacing, GFCI/AFCI requirements, overcurrent protection, and lighting outlets

15%

Grounding & Bonding

Grounding electrode systems, equipment grounding, bonding requirements, and ground-fault protection

20%

Wiring Methods & Materials

Conductor ampacity, conduit fill, cable assemblies, box fill calculations, and raceway types

25%

Services, Feeders, Motors & Special Occupancies

Service entrance requirements, load calculations, motor circuits, transformers, hazardous locations, and healthcare facilities

How to Pass the RI Electrician Exam

What You Need to Know

  • Passing score: 70%
  • Exam length: 80 questions
  • Time limit: 4 hours
  • Exam fee: $50-$75

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

RI Electrician Study Tips from Top Performers

1Master NEC Article 250 (Grounding and Bonding) — this is the most heavily tested topic
2Practice dwelling unit load calculations using NEC Article 220 until they are second nature
3Study the 2020 NEC specifically — Rhode Island has not yet adopted the 2023 edition
4Focus on conductor ampacity from Table 310.16 and temperature correction factors
5Study motor circuit requirements in Article 430, including overload and short-circuit protection

Frequently Asked Questions

What NEC edition does Rhode Island use for the electrician exam?

Rhode Island uses the 2020 NEC for the journeyman electrician exam. The state has not yet adopted the 2023 edition. The exam allows a bound copy of the 2020 NEC as a reference.

Who administers the Rhode Island electrician exam?

Unlike most states that use PSI or Prometric, Rhode Island administers the exam directly through the RI Electricians' Examination & Licensing Board. Contact the board directly for scheduling and registration information.

How hard is the Rhode Island electrician exam?

The exam is challenging with an estimated 55% first-time pass rate. It covers approximately 80 questions in 4 hours. Strong NEC navigation skills and load calculation practice are essential for success.

How much does the Rhode Island electrician exam cost?

The exam fee is approximately $50-$75 through the RI Electricians' Examination & Licensing Board. Additional costs include the NEC codebook and study materials.