All Practice Exams

100+ Free Nutanix NCP-CI-AWS Practice Questions

Pass your Nutanix Certified Professional - Cloud Integration AWS (NCP-CI-AWS) exam on the first try — instant access, no signup required.

✓ No registration✓ No credit card✓ No hidden fees✓ Start practicing immediately
Not publicly published Pass Rate
100+ Questions
100% Free
1 / 100
Question 1
Score: 0/0

Which AWS instance family is required to run Nutanix Cloud Clusters (NC2) on AWS?

A
B
C
D
to track
2026 Statistics

Key Facts: Nutanix NCP-CI-AWS Exam

75

Questions

Nutanix exam page

120 min

Time Limit

Nutanix exam page

3000/6000

Passing Score

Nutanix scaled

US$199

Exam Fee

Pearson VUE

2 years

Cert Validity

Nutanix policy

i3.metal / i4i.metal

Supported AWS SKUs

Nutanix NC2 docs

NCP-CI-AWS is a Nutanix specialty exam delivered through Pearson VUE, typically 75 questions in 120 minutes with a scaled passing score of 3000/6000 and a US$199 fee. The exam validates skills running Nutanix Cloud Clusters (NC2) on AWS bare-metal nodes (i3.metal/i4i.metal). Domain coverage spans planning & deploying NC2 clusters, AWS prerequisites and IAM, hybrid connectivity (Transit Gateway/Direct Connect/VPC peering), AHV vs ESXi tradeoffs, NCU billing and hibernate/resume cycles, LCM upgrades, and DR via Leap, Files Smart DR, and Objects replication.

Sample Nutanix NCP-CI-AWS Practice Questions

Try these sample questions to test your Nutanix NCP-CI-AWS exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1Which AWS instance family is required to run Nutanix Cloud Clusters (NC2) on AWS?
A.t3 general-purpose instances
B.Bare-metal instances such as i3.metal and i4i.metal
C.Graviton-based c7g instances
D.m5 general-purpose instances
Explanation: NC2 on AWS runs on AWS bare-metal instances because the AHV or ESXi hypervisor must execute directly on physical hardware to manage CPU, memory, and NVMe storage. Supported bare-metal types include i3.metal, i3en.metal, and i4i.metal. Standard virtualized instances cannot host Nutanix CVMs.
2From which portal do administrators deploy and manage Nutanix Cloud Clusters on AWS?
A.AWS Management Console only
B.Nutanix Prism Element on the customer's on-prem cluster
C.Nutanix Cloud Portal (My Nutanix) at cloud.nutanix.com
D.AWS Marketplace dashboard
Explanation: NC2 clusters are provisioned, scaled, hibernated, and terminated through the Nutanix Cloud Portal (cloud.nutanix.com / My Nutanix). The portal orchestrates AWS API calls to create the cluster on bare-metal instances. AWS Console is used only for AWS-side prerequisites such as VPCs and IAM roles.
3What is the minimum number of bare-metal nodes required to deploy a production NC2 on AWS cluster?
A.1 node
B.2 nodes
C.3 nodes
D.5 nodes
Explanation: NC2 on AWS requires a minimum of three bare-metal nodes to form a production cluster, which supports Replication Factor 2 (RF2) for data resiliency. A single-node configuration is not supported in production NC2 deployments because RF2 requires at least three nodes to safely tolerate a node failure.
4Which AWS networking construct must exist before deploying an NC2 cluster?
A.A Direct Connect circuit
B.A customer-owned VPC with at least one subnet in the target Availability Zone
C.A Transit Gateway attached to two regions
D.An Elastic Load Balancer
Explanation: NC2 deployment requires an existing customer-managed VPC with subnets in the AZ where bare-metal capacity will be allocated. Cluster nodes are provisioned into that VPC. Direct Connect, Transit Gateway, and ELBs are optional integrations, not prerequisites.
5What does the NC2 Hibernate feature do to a running cluster?
A.Powers off CVMs but keeps bare-metal nodes billed at full rate
B.Saves cluster state and data to AWS S3, then releases the bare-metal nodes to stop bare-metal compute charges
C.Migrates the cluster to a different AWS region
D.Deletes the cluster permanently
Explanation: Hibernate persists cluster metadata and data to Amazon S3, then releases the bare-metal EC2 instances so AWS hourly bare-metal compute charges stop. Storage in S3 still incurs cost, but the expensive compute charge is paused. Resume re-provisions bare metal and rehydrates state from S3.
6Which hypervisor is supported on NC2 on AWS as of the current release?
A.AHV only
B.ESXi only
C.AHV and ESXi
D.Hyper-V
Explanation: NC2 on AWS supports both AHV (Nutanix's native KVM-based hypervisor) and VMware ESXi on bare-metal nodes. Customers choose the hypervisor at cluster creation time in the Nutanix Cloud Portal. Hyper-V is not supported on NC2 on AWS.
7Which AWS IAM construct does the Nutanix Cloud Orchestrator assume to provision NC2 resources in a customer account?
A.An IAM user with long-lived access keys
B.A cross-account IAM role with a defined trust policy and permissions policy
C.An EC2 instance profile attached to each node
D.An AWS root account credential
Explanation: NC2 onboarding creates a cross-account IAM role in the customer's AWS account with a trust policy allowing Nutanix's orchestrator account to assume it. The role's permissions policy grants exactly the EC2, VPC, and S3 actions needed for cluster lifecycle. Long-lived keys and root credentials are not used.
8What is the unit of consumption used to license NC2 software on AWS?
A.Per VM per month
B.Nutanix Cloud Units (NCUs) drawn from a Nutanix Cloud commit
C.Per CVM per hour
D.Per AWS Availability Zone
Explanation: Nutanix software on NC2 is consumed in Nutanix Cloud Units (NCUs), typically purchased as a Nutanix Cloud commit and burned down by running clusters. AWS bare-metal compute and S3 storage are billed separately by AWS at the standard hourly EC2 bare-metal rate.
9Which Nutanix tool is used to upgrade AOS, AHV, and firmware on an NC2 cluster?
A.AWS Systems Manager Patch Manager
B.Life Cycle Manager (LCM) inside Prism
C.Foundation Central
D.CloudFormation StackSets
Explanation: Life Cycle Manager (LCM), accessed inside Prism Element or Prism Central, performs one-click upgrades for AOS, AHV, NCC, and supported firmware on NC2 clusters. AWS Systems Manager and CloudFormation are not used to update Nutanix software.
10What network overlay does AHV on NC2 use to provide UVM (User VM) networking that is independent of the underlying AWS VPC subnet?
A.Native AWS Elastic Network Interfaces only
B.Flow Virtual Networking with overlay subnets
C.AWS Transit Gateway tunnels
D.BGP-routed subnets
Explanation: On NC2 with AHV, Flow Virtual Networking provides overlay networking so UVMs receive IPs from Nutanix-managed subnets independent of the underlying AWS VPC CIDR. This avoids burning AWS subnet IPs per VM and supports VPC isolation, NAT, and routing inside the cluster.

About the Nutanix NCP-CI-AWS Exam

The Nutanix NCP-CI-AWS exam validates the skills needed to deploy and operate Nutanix Cloud Clusters (NC2) on AWS bare-metal infrastructure. Coverage includes deployment via the Nutanix Cloud Portal, AWS prerequisites (VPC, subnets, IAM roles), networking with Flow Virtual Networking and AWS native VPCs, hybrid connectivity (Transit Gateway, Direct Connect, VPC peering), capacity & cost management with NCUs, hibernate/resume operations, LCM upgrades, and disaster recovery scenarios using Leap, Files Smart DR, and Objects replication.

Questions

75 scored questions

Time Limit

120 minutes

Passing Score

3000/6000 (Nutanix scaled)

Exam Fee

US$199 (Nutanix / Pearson VUE)

Nutanix NCP-CI-AWS Exam Content Outline

25%

Plan and Deploy NC2 on AWS

Planning NC2 cluster sizing, supported regions, AWS bare-metal SKUs (i3.metal, i4i.metal), Nutanix Cloud Portal deployment workflow, AWS prerequisites (VPC, subnets, security groups, IAM roles), Cross-Account IAM Role for NC2.

25%

Configure Networking

Flow Virtual Networking on NC2, native AWS VPC integration, hybrid connectivity (Transit Gateway, Direct Connect, VPC peering), AWS Direct Connect for low-latency hybrid, VPC endpoints, route propagation, NSG and security group design.

25%

Operate and Manage NC2

Day-2 operations: hibernate/resume cycles, scale-out/scale-in, LCM (Lifecycle Manager) upgrades, AOS upgrade paths, capacity planning with NCU billing, integration with Prism Central from on-prem, monitoring with CloudWatch + Prism.

25%

Data Mobility and DR

Disaster recovery using Nutanix Leap with NC2 + on-prem cluster failover, Files Smart DR replication, Objects bucket replication, Move tool for VM migration to AHV, AHV vs ESXi licensing on AWS bare metal.

How to Pass the Nutanix NCP-CI-AWS Exam

What You Need to Know

  • Passing score: 3000/6000 (Nutanix scaled)
  • Exam length: 75 questions
  • Time limit: 120 minutes
  • Exam fee: US$199

Keys to Passing

  • Complete 500+ practice questions
  • Score 80%+ consistently before scheduling
  • Focus on highest-weighted sections
  • Use our AI tutor for tough concepts

Nutanix NCP-CI-AWS Study Tips from Top Performers

1Spin up an NC2 trial via the Nutanix Cloud Portal to walk through the actual deployment wizard — IAM role creation and capacity reservation are heavily tested.
2Master the AWS prerequisites: cross-account IAM role, dedicated subnet, security groups, capacity reservation, and EBS-backed prism storage.
3Drill the hibernate/resume workflow — many questions ask which Prism / NC2 console actions are valid in each state.
4Know the difference between Flow Virtual Networking on NC2 and using native AWS VPC subnets directly for UVMs.
5Memorize hybrid connectivity options: Transit Gateway vs VPC peering vs Direct Connect vs VPN, including BGP behavior.
6Practice DR scenarios: Leap protection policies between NC2-AWS and on-prem, Files Smart DR for SMB shares, Objects bucket replication.
7Review LCM workflows in NC2 and AOS upgrade prerequisites — they differ slightly from on-prem clusters.

Frequently Asked Questions

What is the Nutanix NCP-CI-AWS exam?

NCP-CI-AWS is the Nutanix Certified Professional – Cloud Integration AWS exam. It validates skills running Nutanix Cloud Clusters (NC2) on AWS bare-metal infrastructure, including deployment, networking, hybrid connectivity, hibernate/resume cycles, LCM upgrades, and disaster recovery scenarios.

How many questions and how long is the NCP-CI-AWS exam?

The exam typically has 75 questions and is 120 minutes long. Nutanix uses a scaled scoring system from 1000 to 6000, with a passing score of 3000.

What is the passing score for NCP-CI-AWS?

The passing score is 3000 out of 6000 on Nutanix's scaled scoring system. Nutanix does not publish a percentage equivalent.

How much does the NCP-CI-AWS exam cost?

The list price is approximately US$199 (plus applicable taxes), delivered via Pearson VUE.

Are there prerequisites for NCP-CI-AWS?

Nutanix recommends prior experience with Nutanix AOS / Prism Central plus AWS networking fundamentals. NCP-MCI is helpful but not strictly required.

How long is NCP-CI-AWS valid for?

Nutanix professional certifications are valid for 2 years. Renewal requires retaking the exam at the current version or earning a higher-level certification.