All Practice Exams

Free Practice Questions for CDCP

Exam-style questions and explanations by OpenExamPrep.

✓ No registration✓ No credit card
135+ Questions
100% Free
Exam Review

Key Facts: CDCP Exam

40

Exam Questions

EXIN Preparation Guide

60 min

Exam Duration

EXIN Preparation Guide

68%

Passing Score (27/40)

EXIN Preparation Guide

3 years

Certification Validity

EPI Recertification Program

85% / 15%

Facilities vs Operations Weighting

EXIN Preparation Guide

60+

Countries Where EPI Delivers Training

EPI

The CDCP exam has 40 multiple-choice questions in 60 minutes with a 68% passing score (27 of 40). Coverage spans Facilities of the Data Centre (~85%) and Operations of the Data Centre (~15%), including Uptime Tier classification, TIA-942 Rated facilities, EN 50600 / ISO 22237, UPS and generator topologies, ASHRAE TC 9.9 thermal envelopes, hot/cold aisle and containment, free cooling, NFPA fire suppression, layered physical security, structured cabling, DCIM/BMS/EPMS, PUE/WUE/CUE metrics, and BCDR fundamentals.

Sample CDCP Practice Questions

Try these sample questions to review concepts for the CDCP exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 135+ question experience with AI tutoring.

1What is the MINIMUM Uptime Tier requiring planned isolation of every required capacity component and distribution-path element without IT interruption?
A.Tier I
B.Tier II
C.Tier III
D.Tier IV
Explanation: Tier III adds concurrent maintainability to redundant capacity. It permits planned isolation without IT interruption. Tier IV also meets this requirement and adds fault tolerance, but is not the minimum. Current Tier definitions assign no predicted annual availability percentage.
2What is the formula for Power Usage Effectiveness (PUE)?
A.IT equipment energy / total facility energy
B.Total facility energy / IT equipment energy
C.Cooling energy / IT equipment energy
D.(Total facility energy - IT energy) / IT equipment energy
Explanation: PUE is total facility energy divided by IT equipment energy over the same period and boundary. It measures infrastructure overhead, not useful IT output. A complete conventional boundary gives PUE at least 1.
3Which redundancy configuration uses two completely independent systems each capable of carrying the full IT load by itself?
A.N
B.N+1
C.2N
D.N+2
Explanation: 2N denotes two independent systems, each capable of the full design load. Independence must include the relevant sources, controls and distribution. Uptime evaluates full Tier outcomes; a 2N label alone does not establish Tier IV certification.
4According to ANSI/TIA-942, which Rated Facility level corresponds most closely to a 'Fault Tolerant' data centre with concurrent maintainability and fault tolerance?
A.Rated-1
B.Rated-2
C.Rated-3
D.Rated-4
Explanation: TIA-942 uses Rated-1 Basic, Rated-2 Redundant Capacity Components, Rated-3 Concurrently Maintainable and Rated-4 Fault Tolerant. The concepts resemble Uptime Tiers but certification criteria and programs are separate; one award does not establish the other.
5Which European series addresses data-centre facilities with availability, security and energy-efficiency criteria?
A.EN 50173
B.EN 50600
C.EN 50310
D.EN 50346
Explanation: EN 50600 addresses data-centre facilities and infrastructure, including availability, security, energy-efficiency enablement and related KPIs. ISO/IEC 22237 is the associated international facilities framework. These criteria do not amount to a G/A/E/P rating formula.
6Which listed agent is heptafluoropropane, historically sold for fire suppression as FM-200?
A.HFC-227ea
B.FK-5-1-12
C.IG-541
D.CO2
Explanation: FM-200 is HFC-227ea, a halocarbon clean agent, not a blend. It suppresses mainly through heat absorption and leaves no residue. High GWP, local HFC rules and supply affect selection; occupied-space use requires approved concentration/exposure limits and evacuation safeguards.
7What is the primary functional difference between a CRAC and a CRAH unit?
A.A CRAC uses water; a CRAH uses refrigerant.
B.A CRAC uses refrigerant (DX coil); a CRAH uses chilled water.
C.Both use refrigerant; CRAH is larger.
D.CRAH is for raised floor only; CRAC is for slab only.
Explanation: In conventional terminology, a CRAC uses a direct-expansion refrigeration circuit; a CRAH uses a chilled-water coil supplied by a central plant and has no local refrigeration compressor. Whole-system efficiency depends on the actual equipment and operating conditions.
8Among ASHRAE classes A1-A4, which has the widest allowable dry-bulb range, 5-45 C, at reference conditions?
A.Class A1
B.Class A2
C.Class A3
D.Class A4
Explanation: A4 permits 5-45 C at the reference conditions. A1-A4 share a recommended 18-27 C inlet range, but allowable humidity, dew-point, altitude and rate-of-change limits also apply. Allowable functionality is not a recommendation for continuous operation at an extreme.
9Which UPS topology normally supplies the load through an AC-to-DC rectifier and a DC-to-AC inverter?
A.Offline (standby) UPS
B.Line-interactive UPS
C.Double-conversion (online) UPS
D.Ferroresonant UPS
Explanation: Online double-conversion UPS normally supplies the load through its inverter. Battery takeover can cause no output interruption in this mode. This does not imply galvanic isolation or immunity to every transient; bypass and efficiency depend on the product and operating mode.
10What is the primary purpose of an Automatic Transfer Switch (ATS) in a data centre?
A.Converts battery DC into output AC
B.Selects an acceptable utility or generator source
C.Clamps short overvoltage transients
D.Regulates the output voltage continuously
Explanation: An ATS detects source conditions and transfers the load to an acceptable alternate source. Total restoration time includes source startup/stabilization and configured delays. Open transition breaks before make; closed transition briefly parallels acceptable sources.

About the CDCP Exam

The EXIN Certified Data Centre Professional (CDCP) validates foundational knowledge of data centre facility infrastructure: standards (TIA-942, EN 50600, Uptime Tiers), site selection and building, raised floor, power distribution and UPS topologies, cooling systems and ASHRAE guidelines, fire protection, physical security, structured cabling, monitoring, and operations and maintenance.

Exam sponsor: EXIN (accreditation) / EPI (courseware). The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

40 questions

Time Limit

60 minutes

Passing Score

68% (27 of 40)

Exam / Certification Fees

US$895 EPI Academy Training On Demand (exam included); US$795 / US$675 AFCOM classroom benchmark

Exam sponsor website

Reported exam pass rate: Not published. EXIN and EPI do not release official CDCP pass-rate statistics Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

Not published

Standards & Mission Critical Site

Uptime Institute Tiers I-IV, ANSI/TIA-942 Rated-1 to Rated-4 facilities, EN 50600 series and ISO/IEC 22237, EPI DCOS, mission critical site definitions, and availability targets

Not published

Building, Raised Floor & Auxiliary Systems

Site selection criteria, structural loading, raised access flooring, suspended ceilings, lighting and EPS, EMF shielding, water supply, BMS, EPMS, DCIM, and water leak detection

Not published

Power Infrastructure

Power distribution from utility to rack, UPS topologies (offline, line-interactive, double-conversion), generators, ATS/STS, redundancy (N, N+1, 2N, 2(N+1)), grounding/SRG, harmonics, SPDs, and EPO

Not published

Cooling Infrastructure

ASHRAE TC 9.9 envelopes, CRAC vs CRAH, hot/cold aisle, containment, free cooling (air-side and water-side economizer), evaporative/adiabatic cooling, in-row, RDHx, immersion, and direct-to-chip

Not published

Fire Protection & Physical Security

NFPA 75/76, smoke detection, VESDA, gaseous suppression (FM-200, Novec 1230, IG-541), water mist, layered physical security, mantraps, biometrics, CCTV, and EN 50131 IDS

Not published

Cabling, Operations & Efficiency

TIA-942 topology (MDA/HDA/ZDA/EDA), Cat 6A, OM3/OM4/OM5, single-mode, MTP/MPO, SOP/MOP/EOP, AOR, commissioning levels, preventive vs predictive maintenance, PUE/WUE/CUE, ISO 30134, BCDR with RTO/RPO

Preparing for the CDCP Exam

What You Need to Know

  • Passing score: 68% (27 of 40)
  • Exam length: 40 questions
  • Time limit: 60 minutes
  • Exam / certification fees: US$895 EPI Academy Training On Demand (exam included); US$795 / US$675 AFCOM classroom benchmark Official sources

Using Our Practice Resources

  • Work through all 135 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

CDCP: Suggested Study Strategy

1Memorize the four Uptime Tiers with their availability targets (99.671%, 99.741%, 99.982%, 99.995%) and what makes Tier III concurrently maintainable
2Know the difference between ANSI/TIA-942 Rated-1 to Rated-4 and how they map to (but are not identical to) Uptime Tiers
3Master redundancy schemes: N, N+1, 2N, and 2(N+1) — and which Tier each enables
4Learn UPS topologies cold: offline vs line-interactive vs double-conversion, plus when STS vs ATS is appropriate
5Memorize ASHRAE TC 9.9 recommended envelope (18-27 °C) and the allowable envelopes for classes A1-A4
6Know the major clean agents (FM-200/HFC-227ea, Novec 1230/FK-5-1-12, IG-541/Inergen, IG-55) and their environmental profiles
7Practice the PUE formula and CUE/WUE definitions — calculation questions appear on every exam
8Understand SOP vs MOP vs EOP, AOR, and the commissioning levels (Cx 1-5) including pull-the-plug IST

Frequently Asked Questions

What is the CDCP exam format?

The CDCP exam consists of 40 closed-book multiple-choice questions to be completed in 60 minutes. The passing score is 27 out of 40 (68%). Questions cover the full data centre facility infrastructure plus operational considerations, weighted approximately 85% facilities and 15% operations.

Who accredits the CDCP and who delivers the training?

CDCP is globally accredited by EXIN, an independent exam and certification institute. The official courseware and instructor-led training are delivered by EPI (Enterprise Products Integration), with delivery through EPI partner training centres in over 60 countries.

Is the CDCP exam included in the training fee?

The CDCP exam voucher is often bundled with EPI's two-day instructor-led, virtual, or on-demand training. Standalone exam availability and package pricing vary by region and delivery provider, so confirm the current route with EXIN or the local EPI partner before booking.

What are the prerequisites for CDCP?

CDCP training is mandatory for certification, but the course itself has no specific prerequisite. EPI recommends 1-2 years of experience in a data centre or facilities environment, and newcomers are welcome. CDCP is the first credential in the EPI Design and Build training track and feeds into CDCS (Specialist) and CDCE (Expert).

How long is the CDCP certification valid?

The CDCP certificate is valid for 3 years. Recertification can be achieved through the EPI Recertification Programme, which includes options like attending updated training, completing CPE-style activities, or progressing to higher-level credentials such as CDCS or CDCE.