100+ Free ASSE 5110 Practice Questions
Pass your ASSE 5110 Backflow Prevention Assembly Tester exam on the first try — instant access, no signup required.
What is the minimum number of shutoff valves required on a testable backflow prevention assembly?
Explore More ASSE Plumbing Certifications
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
Key Facts: ASSE 5110 Exam
100
Written Exam Questions
ASSE Series 5000
70%
Passing Score
ASSE Series 5000
40 hrs
Minimum Course Length
ASSE-approved schools
5 yrs
Required Experience
ASSE 5110 standard
3 years
Recertification Cycle
ASSE recertification policy
$600-$1,150
Typical Course + Exam
IAPMO / BPI providers
ASSE 5110 requires a minimum 40-hour ASSE-approved course, a 100-question written exam at 70% or higher, and a hands-on practical demonstration of the field test procedure for RP, DC, PVB, and SVB assemblies. Prerequisites typically include five years of documented plumbing, pipefitting, mechanical, or fire protection experience. The certification is valid for three years before recertification is required. Effective study focuses on the USC FCCCHR field test procedures, internal operation of each assembly, differential pressure gauge use, and the ASSE Series 5000 standard.
Sample ASSE 5110 Practice Questions
Try these sample questions to test your ASSE 5110 exam readiness. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.
1Backflow caused by a pressure downstream of the backflow preventer that exceeds the supply pressure is called:
2Which assembly provides the highest level of mechanical backflow protection and is approved for health hazards under backpressure?
3An RP assembly contains how many independently acting check valves?
4Which device standard covers the reduced pressure principle backflow prevention assembly?
5Which device standard covers the double check valve assembly?
6Which device standard covers the pressure vacuum breaker assembly?
7Which device standard covers the spill-resistant vacuum breaker?
8What is the minimum number of shutoff valves required on a testable backflow prevention assembly?
9An RP assembly has how many test cocks?
10Which of the following is approved for backsiphonage only and cannot be installed under continuous pressure?
About the ASSE 5110 Exam
ASSE 5110 is the national certification for Backflow Prevention Assembly Testers who field-test reduced pressure (RP), double check (DC), pressure vacuum breaker (PVB), and spill-resistant vacuum breaker (SVB) assemblies. The written exam covers hydraulic principles, assembly operation, differential pressure gauge use, USC FCCCHR field test procedures, installation requirements, ASSE 1013/1015/1020/1056 devices, and federal references such as the SDWA, EPA 816-R-03-002, and AWWA M14. The practical exam requires the candidate to demonstrate the correct test procedure on a live or training assembly without notes.
Assessment
Written exam plus hands-on practical test of RP, DC, PVB, and SVB assemblies
Time Limit
Provider-set written time, plus a hands-on practical on the last day of class
Passing Score
70% on the written exam plus a successful hands-on practical
Exam Fee
$600-$1,150 typical course + exam (varies by provider) (ASSE International / IAPMO)
ASSE 5110 Exam Content Outline
Hydraulics and Backflow Theory
Backpressure, backsiphonage, atmospheric pressure, velocity head, and how pressure differentials cause backflow in a distribution system.
Backflow Assembly Components and Operation
Internal parts and operation of RP (ASSE 1013), DC (ASSE 1015), PVB (ASSE 1020), SVB (ASSE 1056), RPDA (ASSE 1047), and DCDA (ASSE 1048) assemblies.
Field Test Procedures
Step-by-step USC FCCCHR and ASSE field test procedures for RP, DC, PVB, and SVB assemblies including reading and interpreting differential pressure and air inlet opening points.
Test Equipment and Calibration
Three- and five-valve differential pressure gauges, gauge hose hookup, bleeding procedures, calibration intervals, and field accuracy verification.
Installation Requirements and Inspection
Orientation, minimum clearance, drainage of the relief valve, freeze protection, thermal expansion control, and pre-test visual inspection.
Codes, Standards, and Manuals
ASSE/IAPMO/ANSI Series 5000 standard, ASSE 1013/1015/1020/1056 device standards, USC Manual of Cross-Connection Control 10th Edition, AWWA M14, EPA 816-R-03-002, and the SDWA framework.
Cross-Connection Recognition
Common health and non-health hazards a tester encounters in the field and the correct assembly for each scenario.
How to Pass the ASSE 5110 Exam
What You Need to Know
- Passing score: 70% on the written exam plus a successful hands-on practical
- Assessment: Written exam plus hands-on practical test of RP, DC, PVB, and SVB assemblies
- Time limit: Provider-set written time, plus a hands-on practical on the last day of class
- Exam fee: $600-$1,150 typical course + exam (varies by provider)
Keys to Passing
- Complete 500+ practice questions
- Score 80%+ consistently before scheduling
- Focus on highest-weighted sections
- Use our AI tutor for tough concepts
ASSE 5110 Study Tips from Top Performers
Frequently Asked Questions
What does an ASSE 5110 Backflow Prevention Assembly Tester do?
A 5110 Tester performs the annual field test required by the water purveyor and the AHJ on reduced pressure (RP), double check (DC), pressure vacuum breaker (PVB), and spill-resistant vacuum breaker (SVB) assemblies. The tester confirms that each check valve holds tight, that the differential pressure relief valve on an RP opens at the correct value, and that air inlets on a PVB or SVB open at or above the required pressure, then reports the result to the purveyor.
How many questions are on the ASSE 5110 exam and what is the passing score?
The ASSE 5110 written examination is 100 questions and requires a score of 70% or higher to pass. Candidates must also pass a hands-on practical exam that includes the field test procedure for RP (ASSE 1013), DC (ASSE 1015), PVB (ASSE 1020), and SVB (ASSE 1056) assemblies without notes or assistance.
What are the prerequisites for ASSE 5110 certification?
The ASSE 5110 standard requires a minimum of five years documented practical experience in plumbing, pipefitting, mechanical, fire protection, or a related field. Candidates must also complete a minimum 40-hour ASSE-approved course before sitting for the written and practical exams. Some providers accept equivalent education or military experience in lieu of part of the five-year requirement; check with your ASSE-approved school.
How long is the ASSE 5110 Tester certification valid?
ASSE 5110 certification is valid for three years. To maintain the credential, testers must complete an ASSE-approved recertification course and pass a recertification exam before the expiration date. Letting the certification lapse typically requires retaking a full initial course.
What is the difference between an RP and a DC assembly?
A reduced pressure principle (RP) assembly meeting ASSE 1013 contains two independently acting check valves and a differential pressure relief valve between them, so the zone between the checks discharges to atmosphere if either check fouls. A double check valve assembly (DC) meeting ASSE 1015 also has two checks but no relief valve. RPs protect against health hazards including backpressure; DCs are used only for non-health hazards.
How often should a backflow tester gauge be calibrated?
Most jurisdictions and the USC Manual of Cross-Connection Control require the differential pressure gauge to be calibrated at least once every twelve months, and many purveyors require a calibration sticker on the gauge to accept the test report. Testers should also verify gauge accuracy in the field if a reading appears unusual or after the gauge has been dropped.
Which reference manuals should I study for ASSE 5110?
Primary references include the USC Foundation for Cross-Connection Control and Hydraulic Research (FCCCHR) Manual of Cross-Connection Control (10th Edition), AWWA M14 Recommended Practice for Backflow Prevention and Cross-Connection Control, EPA's Cross-Connection Control Manual (EPA 816-R-03-002), and the ASSE/IAPMO/ANSI Series 5000 standard along with the ASSE 1013, 1015, 1020, and 1056 device standards.