Key Facts: I.A.(MR) Exam

120 items

100 scored plus 20 pilot

ARRT I.A.(MR) handbook and credential page; checked October 19, 2026

120 minutes

Test time; 140-minute appointment

ARRT I.A.(MR) handbook and credential page; checked October 19, 2026

75 and 7.5

Overall and Safety passing thresholds

ARRT I.A.(MR) handbook and credential page; checked October 19, 2026

31% / 37% / 32%

Patient Care / Safety / Positioning

ARRT I.A.(MR) handbook and credential page; checked October 19, 2026

$225 standard

Initial fall 2026 window had a deadline-limited $75 fee

ARRT I.A.(MR) handbook and credential page; checked October 19, 2026

The I.A.(MR) exam has 100 scored items and 20 pilot items with 120 minutes of testing in a 140-minute appointment. The scored distribution is Patient Care 31, Safety 37 and Positioning/Anatomical Landmarking 32. Passing requires 75 overall and 7.5 in MRI Screening and Safety. The initial fall 2026 application deadline was October 14; approved candidates test October 15–November 30 for $75. Later applications use the standard $225 fee and testing on or after January 1, 2027. Imaging assistants support MR care and authorized clinical tasks but do not select protocols, acquire images or interpret studies. Facts checked October 19, 2026 against ARRT’s current credential page and handbook.

Sample I.A.(MR) Practice Questions

Try these sample questions to review concepts for the I.A.(MR) exam. Each question includes a detailed explanation. Start the interactive quiz above for the full 100+ question experience with AI tutoring.

1An imaging assistant (I.A.) working under a registered MR technologist notices a patient's wheelchair contains a clearly labeled ferromagnetic frame. Where must the wheelchair stop before entering Zone IV?
A.At the Zone III controlled-access door
B.Only when it sets off the ferromagnetic detector
C.At the scanner bore
D.Inside Zone IV next to the magnet
Explanation: Per ACR and ARRT MR safety guidance, ferromagnetic items must never cross into Zone IV (the magnet room). Access to Zone III is restricted and access to Zone IV requires screening clearance. The wheelchair must stop outside Zone III or be exchanged for an MR Conditional wheelchair before the patient enters the scan room.
2Which document outlines the professional conduct and ethical obligations an ARRT Imaging Assistant must follow?
A.ARRT Standards of Ethics
B.AMA Principles of Medical Ethics
C.Joint Commission Patient Safety Goals
D.The Hippocratic Oath
Explanation: The ARRT Standards of Ethics — which include the Code of Ethics and the Rules of Ethics — applies to all ARRT candidates and credential holders, including Imaging Assistants. It defines aspirational standards and enforceable rules of conduct. Candidates must attest to ethics compliance at application and at every annual renewal.
3A patient presents for an MRI brain exam and shows the I.A. an implant card indicating a deep brain stimulator (DBS). What is the correct next step?
A.Stop the screening and escalate to the MR technologist and MR Safety Officer for conditional review
B.Proceed with scanning because modern DBS devices are MR Safe
C.Remove the external programmer and scan as usual
D.Send the patient for CT instead without documenting
Explanation: Deep brain stimulators are MR Conditional at best, and scanning requires verification of the device model, field strength, coil, SAR, and specific programmer settings. The I.A. must escalate to the MR technologist and MR Safety Officer/Medical Director who determine whether the conditions can be met before any scan proceeds.
4Under ARRT scope of practice, which of the following tasks is an Imaging Assistant NOT permitted to perform?
A.Independently prescribe and set scan parameters on the MR console
B.Position a cooperative adult for a routine lumbar spine MRI under direct technologist supervision
C.Assist the technologist with patient transfer from a stretcher to the MR table
D.Screen a patient for ferromagnetic objects using the screening form
Explanation: Imaging Assistants support MR technologists but do not perform imaging or prescribe scan parameters. Selecting pulse sequences, running scans, and interpreting images remain the responsibility of a credentialed MR technologist. The I.A. focuses on patient interactions, MR safety screening, patient positioning, and MR environment management.
5HIPAA permits disclosure of protected health information without the patient's authorization for which of the following purposes?
A.Treatment, payment, and healthcare operations
B.Posting anonymized images on a personal social media account
C.Discussing the case in a public elevator with another I.A.
D.Sharing scan images with a patient's friend who drove them to the appointment
Explanation: Under the HIPAA Privacy Rule, covered entities may use or disclose PHI without patient authorization for treatment, payment, and healthcare operations (TPO). All other purposes generally require authorization. Casual conversation in public spaces and social media posts, even if 'anonymized,' are not permitted disclosures.
6Which of the following is classified as MR Unsafe?
A.A steel oxygen tank
B.A titanium orthopedic screw
C.A plastic IV pole
D.A ceramic coffee mug
Explanation: MR Unsafe items contain ferromagnetic material and pose a projectile hazard near the magnet. Steel oxygen tanks are a classic example and must never enter Zone IV. Titanium is generally MR Conditional or MR Safe, plastic and ceramic without metal are MR Safe. ASTM labeling requires MR Unsafe items to carry a red 'MR' symbol with a diagonal line.
7Which CDC Standard Precaution applies to every patient regardless of suspected infection status?
A.Hand hygiene before and after every patient contact
B.Full airborne isolation
C.N95 respirator use only
D.Negative pressure rooms
Explanation: Hand hygiene is the single most important component of Standard Precautions and applies to every patient encounter. Airborne isolation and N95 use are transmission-based precautions applied to specific patients (e.g., suspected tuberculosis). Standard Precautions also include PPE based on anticipated exposure, respiratory hygiene, and safe injection practices.
8An I.A. is helping transfer a frail elderly patient from a stretcher to the MR table. Which action best supports safe patient handling?
A.Use a slide board and the available safe patient handling lift with appropriate staff
B.Have the I.A. lift the patient alone using a bear hug
C.Ask the patient to stand and walk across unassisted
D.Drag the patient by the sheet corner across the gap
Explanation: Safe patient handling requires the use of mechanical aids such as slide boards, transfer devices, and powered lifts with adequate staffing to prevent injury to both patient and worker. Manual lifting of frail patients is discouraged under OSHA and CDC safe patient handling guidance. Body mechanics alone are not sufficient.
9Before any MRI examination, who is ultimately responsible for final safety clearance of a patient into Zone IV?
A.A Level 2 MR personnel member (typically the MR technologist), with oversight by the MR Medical Director
B.The front-desk receptionist
C.The Imaging Assistant acting alone
D.The patient's primary care physician
Explanation: Only Level 2 MR personnel — who have received extensive safety training — may grant final clearance for patients and non-personnel into Zone IV. The MR Medical Director has ultimate accountability for the MR safety program. An Imaging Assistant may collect screening information but cannot provide final clearance alone.
10A patient asks what 'MR Conditional' means on their hip implant card. Which response is correct?
A.The implant has been shown to pose no known hazards under specified MRI conditions (field strength, SAR, gradients)
B.The implant is completely safe in any MRI scanner
C.The implant cannot be scanned in any MRI
D.The implant label is irrelevant to the scan
Explanation: ASTM F2503 defines MR Conditional as posing no known hazards in a specified MR environment, with specified conditions of use (e.g., maximum static field strength, spatial gradient, SAR, scan duration). The technologist must verify each condition before scanning. MR Safe has no known hazards under any condition, and MR Unsafe is dangerous in any scanner.

About the I.A.(MR) Exam

ARRT Imaging Assistant, Magnetic Resonance is an entry-level credential for personnel supporting MR Level 2 safety, patient care, positioning and authorized contrast tasks. Imaging assistants do not perform imaging or scanning. Eligibility requires age 18+, a high school diploma or GED, education, clinical tasks and ARRT ethics compliance.

Exam sponsor: ARRT (American Registry of Radiologic Technologists). The requirements and fees below concern the certification or admission exam, separate from our free practice resources.

Questions

120 questions

Time Limit

120 minutes testing; 140-minute appointment

Passing Score

75 overall and at least 7.5 in MRI Screening and Safety

Exam / Certification Fees

$225 standard; initial fall 2026 window $75 for applications completed by October 14, 2026

Exam sponsor website

Fees, eligibility, and exam policies can change. Confirm them with the exam sponsor before applying or paying.

Our practice resources: topics covered

We aim to reflect publicly available exam outlines and topic information in our study resources. Coverage, format, and difficulty may differ from the actual exam, and we cannot guarantee that every detail is accurate or current. Confirm exam requirements, fees, and policies with the official exam sponsor.

37%

Safety — MRI Screening and Safety

MR safety zones, ferromagnetic screening, biomedical implants (MR Safe/Conditional/Unsafe), electromagnetic fields (static, RF/SAR, gradient), cryogen safety, quench, projectile prevention, Level 1/2 MR personnel, MR Medical Director, MR Safety Officer, emergency procedures, safety event reporting

32%

Positioning and Anatomical Landmarking

Neurological (brain, TMJ, IAC, spine), Body (breast, thorax, brachial plexus, abdomen, MRCP, pelvis, SI joints), Musculoskeletal (wrist, hand, elbow, shoulder, hip, knee, ankle, long bones). Includes anatomy, patient setup, coil selection, isocenter landmarking

31%

Patient Care — Patient Interactions and Management

Ethics (ARRT Standards of Ethics), HIPAA, informed consent, patient rights, communication, patient education, transfer and body mechanics, vital signs, infection prevention (CDC Standard Precautions), pharmacology and contrast media, medical emergencies

Preparing for the I.A.(MR) Exam

What You Need to Know

  • Passing score: 75 overall and at least 7.5 in MRI Screening and Safety
  • Exam length: 120 questions
  • Time limit: 120 minutes testing; 140-minute appointment
  • Exam / certification fees: $225 standard; initial fall 2026 window $75 for applications completed by October 14, 2026 Official sources

Using Our Practice Resources

  • Work through all 100 available questions
  • Review every answer and explanation
  • Track weak areas and revisit them
  • Use our AI tutor for tough concepts

I.A.(MR): Suggested Study Strategy

1Study all three official domains and review safety errors carefully because Safety has its own passing threshold.
2Practice current device-label and patient-preparation scenarios without assuming all implants or scanners share one rule.
3Review anatomy, coil coverage and tolerated positioning for neurological, body, joint and long-bone examinations.
4Use the current ARRT handbook and clinical requirements to plan documentation, eligibility and exam scheduling.

Frequently Asked Questions

What does an ARRT I.A.(MR) do?

Imaging assistants support MR Level 2 safety, patient care, positioning and contrast-related tasks authorized by law, training and facility policy. They do not perform imaging, scanning or interpretation.

What are the eligibility requirements?

Candidates must be 18 or older, have a high school diploma or GED, meet ARRT ethics requirements and document structured education and clinical competencies within the 24-month preapplication window. Verifier and observation requirements differ by category.

How many questions and how much time are allowed?

The examination has 100 scored and 20 pilot items. Test time is 120 minutes; the full appointment is 140 minutes including tutorial, NDA and survey.

What scores are required to pass?

Candidates need at least 75 overall and at least 7.5 in MRI Screening and Safety. These scaled scores are not fixed raw percentages.

What is the exam fee and current testing window?

The standard fee is $225. The one-time $75 fall 2026 fee required application by October 14, 2026, with testing October 15–November 30. Later applications use the standard fee and testing on or after January 1, 2027. Check ARRT for subsequent changes.

How many clinical demonstrations are required?

At least 100 positioning/landmarking demonstrations are required, including at least three in each of 11 mandatory groups. The current rules also limit daily and same-patient counts and volunteer demonstrations; other patient-care, safety and QC competencies are separate.

What happens after an unsuccessful attempt?

ARRT allows three attempts within three years beginning when the first exam window opens. Each attempt requires an application and fee; requalification after exhausting eligibility requires new education and clinical requirements as directed by ARRT.