Tennessee Limited Licensed Electrician Exam Guide 2026: Free LLE Prep
Video
According to the NEC, what is the definition of a 'branch circuit'?
Nec General
Question · Easy
14 on 15, 12 on 20, 10 on 30
Short
Current 2026 Tennessee LLE exam guide: Prov administration, 40 questions, 2 hours, 73% passing score, the ten-subject Prov outline, the three permitted 2017 NEC references, Tennessee's code amendments, the 28 exempt jurisdictions, licensing and renewal steps, and free prep.
Blog
What distinguishes a complete circuit from an open circuit?
General Electrical Knowledge
Flashcard
Which edition of NFPA 70 does Prov list as the code reference for the Tennessee Limited Licensed Electrician exam?
General-use device, not a circuit breaker or fuse, rated in amperes and able to interrupt its rated current at its rated voltage.
General electrical knowledge
Guess the Term
Electrical Theory and Calculations
GEK-1 — Electrical Quantities and Calculation Setup
Study guide
Cheat sheet
Under the 2017 NEC 210.8(A)(6), which dwelling-unit receptacles require GFCI protection?
Branch Circuits
Read the clue and guess the term in 6 tries.
Game
Why are most building loads connected in parallel rather than series?
Under 2017 NEC Table 250.122, what is the minimum copper wire-type equipment grounding conductor size for a circuit protected by a 60-ampere breaker, before any required increase?
Grounding Bonding
Question · Medium
Point on a wiring system where current is taken to supply equipment that uses it.
Under 2017 NEC Table 250.66, what is the minimum copper grounding electrode conductor size for a 2/0 AWG copper ungrounded service-entrance conductor, before electrode-specific allowances?
GFCI inspection
How does Ohm's law connect voltage, current, and resistance?
What is the standard voltage drop recommendation for branch circuits per NEC 210.19(A) Informational Note No. 4?
General term for joining conductors with a device designed for the purpose or by brazing, welding, or soldering with a fusible metal or alloy.
Installation requirements
GEK-2 — DC Circuit Relationships
Per 2017 NEC Table 310.15(B)(16), what is the ampacity of a 6 AWG THWN-2 copper conductor using the 75°C column?
Wiring Methods
Swap tiles to line up three of the same term.
Term Match
What basic power relationships should you recognize for a DC or resistive circuit?
According to NEC 314.16(B), what is the volume allowance for each 12 AWG conductor in a box fill calculation?
Kind of circuit conductors running between the service equipment, or an isolated plant's generator switchboard, and the final branch-circuit overcurrent device.
Services and circuits
Under 2017 NEC Table 430.52, what initial maximum rating applies to a dual-element time-delay fuse protecting a single-phase motor branch circuit from short circuits and ground faults?
Motors Transformers
Why does identifying a continuous load matter before sizing a circuit?
Under 2017 NEC 230.24(B), what minimum vertical clearance applies to overhead service conductors operating at 120 volts to ground over a residential driveway?
Services Feeders
Kind of circuit whose conductors run from the final overcurrent device protecting it to the outlet or outlets.
GEK-3 — AC Systems and Power
According to NEC 220.12, the general lighting load for a dwelling unit is calculated at how many volt-amperes per square foot?
Load Calculations
Flip two cards at a time to find matching terms.
Term Pairs
What does it mean to install listed or labeled equipment according to its instructions?
Installation Requirements
Under 2017 NEC 250.52(A)(5), what is the minimum length of a rod electrode?
Kind of service run made up of the overhead conductors from the last pole or other aerial support to, and including, any splices connecting to the service-entrance conductors at the building.
Under 2017 NEC Chapter 9 Tables 1, 4 and 5, how many 12 AWG THHN conductors fit in a trade size 3/4 EMT run at the standard fill limit?
Question · Hard
What is the purpose of required working space around electrical equipment?
A continuous-duty motor is over 1 hp and has a service factor of at least 1.15. Under 2017 NEC 430.32(A)(1), what percentage of nameplate current is the initial maximum separate overload-trip setting?
Overcurrent protective device with a circuit-opening part that is heated and severed by the overcurrent passing through it.
Overcurrent protection
NEC Navigation and Core Installation Rules
GEK-4 — NEC 2017 Structure, Definitions, and Lookup
What NEC article covers the installation requirements for swimming pools, fountains, and similar installations?
Special Occupancies
Find five hidden terms in a grid of letters.
Term Search
How should unused openings in electrical enclosures be handled?
Per NEC 210.52(A), in dwelling units, receptacle outlets in habitable rooms shall be installed so that no point along the floor line in any wall space is more than how many feet from a receptacle outlet?
Conducting link, intentional or accidental, between a circuit or equipment and the earth or a body that substitutes for it.
Earthing and continuity