Scope & Certification
Not publishedof exam
Walkthrough & Paint
Not publishedof exam
Dust & Soil Sampling
Not publishedof exam
Lab QC & Reporting
Not publishedof exam
Controls, Monitoring & Clearance
Not publishedof exam
Quick Facts
- Credential
- EPA Lead-Based Paint Risk Assessor
- Federal scope
- EPA-administered jurisdictions
- Federal exam
- Meazure Learning third-party exam
- Testing modes
- Online or in person
- Training minimums
- 24h inspector + 16h risk assessor
- Federal exam fee
- $70 per attempt
- Federal exam attempt limit
- 3 within 6 months post-course
- Federal exam logistics
- Follow EPA exam letter
- Public weights
- Not published
Remember Child-Occupied Visits
Same child, under six: two, three, six, sixty.
Inspection vs Risk Assessment
Paint inspection
- Finds and locates lead-based paint
- Tests distinct paint histories
Risk assessment
- Evaluates paint, dust, soil hazards
- Identifies options and prioritizes hazards
Paint inventory vs exposure hazards
Select the Evaluation
- Need locations of lead paint→Paint inspection(Certified inspector or risk assessor)
- Need current hazards and controls→Risk assessment
- Good condition, low hazard likelihood→Consider lead hazard screen
- Screen warrants further evaluation→Follow with full risk assessment
- Need paint inventory and hazards→Combined inspection and risk assessment
- Need post-abatement dust verification→Certified inspector or risk assessor
EPA Certification Path
- Inspector course
- 24h minimum, 8h hands-on
- Risk assessor course
- 16h minimum, 4h hands-on
- Bachelor’s degree
- 1 year related experience
- Associate degree
- 2 years related experience
- High school or equivalent
- 3 years related experience minimum
- Alternative qualification
- Qualifying professional credential
- Initial EPA application
- Apply before third-party exam
- Interim certification
- Expires six months after course
- EPA certification deadline
- Receive certificate within six monthsFrom course completion
- EPA reciprocity
- Valid authorized-program credentialThird-party exam waived
- EPA recertification
- Refresher and application required
- Course test + skills assessment
- Three-year certification cycle
- Course with proficiency test
- Five-year certification cycle
Where Subpart L Applies
- TSCA §402
- Lead activity training and certification
- 40 CFR 745 Subpart L
- Certification and work practices
- 40 CFR 745 Subpart D
- EPA hazard standards
- Target housing
- Pre-1978 housing, with exceptions
- Senior, disability, zero-bedroom housing
- Exception unless under-six child residesAlso if expected to reside
- Child-occupied facility
- Pre-1978, same child under six
- Qualifying weekly visits
- ≥2 days, ≥3h per visit≥6h weekly, ≥60h annually
- EPA-authorized program
- Check administering jurisdictionState, territory, or Tribe
- Title X §1018 disclosure
- Known lead paint, hazards, recordsBefore buyer or tenant commits
- Covered sellers and lessors
- Provide EPA-approved lead information pamphlet
- HUD 24 CFR Part 35
- Lead Safe Housing Rule appliesCovered federally associated housing
- OSHA 29 CFR 1926.62
- Construction worker lead exposure
Plan the Assessment
- Proposal
- Define properties, scope, access, cost
- Potential conflict
- Evaluator profits from control work
- Professional liability coverage
- Evaluation errors and omissions
- Construction worker air action level
- 30 µg/m³, 8-hour average
- Construction worker air limit
- 50 µg/m³, 8-hour averageReduced for longer exposure
- Crew planning
- Verify applicable certifications and roles
Look, Test, Map
Look for damage, test paint, map exposure.
Screen vs Full Assessment
Lead hazard screen
- Limited paint and composite dust
- Follow-up assessment if warranted
Full risk assessment
- Broader paint, dust, soil evaluation
- Required hazard and control details
Match evaluation to property conditions
Site Walkthrough
- Before the visit
- Review prior evaluations and repairs
- Building history
- Age, layout, condition, painting history
- Occupant interview
- Child activity and contact patterns
- Visual inspection
- Locate deterioration, assess extent and causes
- Moisture damage
- Trace source before stabilization
- Hand-to-mouth activity
- Dust and soil ingestion pathway
- Children under six
- Especially vulnerable to lead
- Childhood lead effects
- Learning and nervous system harm
- Other potential lead sources
- Water, air, packaging, food
Paint Hazard Clues
- Peeling, chipping, or chalking
- Deterioration clues
- Friction hazard
- Abraded LBP + dust hazard directly below
- Impact hazard
- LBP damaged by related component
- Chewable hazard
- LBP with visible teeth marks
- Other paint-lead hazard
- Deteriorated LBP indoors or outdoors
- Assessment paint sampling
- Visibly deteriorated surfacesDistinct painting histories
- Screen paint sampling
- Poor paint with distinct histories
XRF and Paint Chips
- LBP finding §745.227(h)(1)
- ≥1.0 mg/cm² or ≥0.5% weight
- LBP
- Lead-based paint
- XRF
- X-ray fluorescence paint testing
- PCS
- Performance characteristic sheet
- PCS controls
- Model-specific limits and calibration checks
- Substrate correction
- Follow the applicable PCS
- Inconclusive XRF
- Confirm with lab paint chipFollow instrument PCS
- Paint chip
- All layers, minimize substrate
- Dust and paint collection
- Take dust before disturbing paint
Dust vs Soil Units
Dust
- Micrograms per square foot
- Wipe lead mass per area
Soil
- Parts per million
- Lead mass per soil mass
Check units before comparing
Choose a Sample
- Visible deterioration, distinct paint history→Test paint for lead
- XRF reading remains inconclusive→Confirm with lab paint chip
- Child-contact floor or interior sill→Collect measured dust wipe
- Child-used facility hall or staircase→Sample floors and interior sills
- Adjacent multifamily common area→Collect floor and sill wipes
- Bare play area or yard→Collect separate soil samples
- Bare dripline or foundation→Include soil sample
- Need pooled dust result→Composite matching component types
Dust Wipe Collection
- ASTM E1728
- Settled-dust wipe collection method
- Residential assessment
- Floors and interior window sillsLikely under-six contact areas
- Multifamily dust
- Adjacent and likely-contact common areas
- Child-occupied facility dust
- Sample child-used rooms, halls, stairsInclude likely-contact common areas
- Residential screen
- Two composites: floors and windowsLikely under-six contact areas
- Multifamily or facility screen
- Add likely-contact common-area composites
- Composite dust minimum
- At least two subsamples
- Composite dust scope
- Include every tested componentOne component type per composite
- Cross-contamination control
- Fresh gloves for each sample
- Dust loading
- Lead mass ÷ wiped areaµg/ft²
- Wipe area conversion
- Square inches ÷ 144
- Worked loading
- 12 µg ÷ 3 ft²4 µg/ft²
Bare Soil Findings
- ASTM E1727
- Field collection of soil samples
- Bare play area
- Composite ≥400 ppm is hazardous
- Rest of bare yard
- Mean ≥1,200 ppm is hazardous
- Bare dripline or foundation
- Sample during risk assessment
- Soil reporting units
- ppm equals µg/g
- Separate sampling areas
- Keep play and non-play distinct
Multifamily Unit Selection
- HUD guidance for similar units
- Targeted, worst-case, or random
- Targeted selection
- Use owner data for highest-risk units
- Worst-case selection
- Assessor walkthrough identifies highest-risk units
- Random selection
- Supports statistical inference
Federal Dust Hazard Determination
- Federal compliance date
- January 12, 2026
- Surfaces covered
- Floors and interior window sills
- Dust-lead reportable level
- Lowest reliably reportable lab loadingVaries by NLLAP laboratory
- Dust hazard trigger
- Any reportable NLLAP wipe result
- Hazard decision unit
- Any single-surface or composite result
- Multifamily unsampled dwelling
- Infer same floor or sill hazardOn the same property
- Multifamily unsampled common area
- Infer same floor or sill hazardWithin same common-area group
- Below laboratory reporting limit
- Lead amount cannot be quantified
Report the Site, Evidence, Hazards, Controls
Site, evidence, hazards, controls.
Blank vs Duplicate
Field blank
- Clean media handled alongside samples
- Reveals contamination
Field duplicate
- Second sample under comparable conditions
- Evaluates precision
Contamination check vs precision check
Lab and Field Quality
- NLLAP
- National Lead Laboratory Accreditation Program
- Recognition scope
- Verify paint, dust, or soil
- Documented methodology
- Include adequate quality control
- Field blank
- Checks handling or media contamination
- Field duplicate
- Checks sampling and analytical precision
- Spiked wipe
- Known lead checks recovery
- Chain of custody
- Record signed and dated transfers
- Sample ID
- Match container, field log, report
- Dust field record
- Exact location, dimensions, component type
Risk vs Abatement Report
Risk assessment report
- Certified risk assessor prepares
- Hazards and suggested control priorities
Abatement report
- Certified supervisor or project designer
- Work performed and clearance results
Assessment guides work, clearance verifies
Risk Assessment Report
- Governing paragraph
- 40 CFR 745.227(d)(11)
- Property identification
- Assessment date, address, unit, construction date
- Contacts
- Owner, applicable certified firm, laboratoryNames, addresses, phone numbers
- Assessor identification
- Name, signature, certification
- Site evidence
- Visual findings and exposure background
- Testing documentation
- Paint methods, locations, XRF serial
- Results
- Field, QC, lab, other sampling
- Prior evaluations
- Include results used in determinations
- Hazard description
- Location, type, severity
- Recommendations
- Options for each hazard, suggested priority
- Enclosure or encapsulation
- Maintenance and monitoring schedule
- Delivery and retention
- Owner copy, retain ≥3 years
Floor, Sill, Trough
Five, forty, one hundred: floor, sill, trough.
Hazard vs Action Level
Dust-lead hazard
- Any reportable NLLAP wipe result
- Floors and interior sills
Dust-lead action levels
- 5, 40, 100 µg/ft²
- Floor, interior sill, trough
- Post-abatement result must be below
Reportable dust can pass clearance
Choose a Control
- Moisture drives paint deterioration→Correct moisture before stabilizing
- Window repeatedly abrades lead paint→Treat friction or replace component
- Need temporary bare soil control→Maintain grass or mulch cover
- Need permanent soil isolation→Use pavement or concrete barrier
- Recommend enclosure or encapsulation→Specify maintenance and monitoring
Control Options
- Interim controls
- Temporary reduction of exposure
- Paint stabilization
- Fix cause, stabilize deteriorated coating
- Specialized cleaning
- HEPA vacuum and wet cleaning
- Encapsulation
- Barrier coating or bonded covering
- Enclosure
- Mechanically fastened rigid barrier
- Abatement
- Designed for permanent hazard eliminationDust below action levels
- Component replacement
- Remove lead-painted component
- Permanent soil cover
- Relatively impermeable barrier
- Replacement soil for abatement
- Near local background, ≤400 ppm
- Reevaluation
- Check recurring hazards and controls
Interim Controls vs Abatement
Interim controls
- Temporary exposure reduction
- Stabilization, cleaning, temporary soil cover
Abatement
- Permanent hazard control by design
- Removal, replacement, permanent barrier
Choose by purpose and durability
Interpret Dust Results
- Floor or sill result reportable→Identify dust-lead hazard
- Reportable dust below action level→EPA recommends cleaning best practices(HEPA vacuuming and damp cleaning)
- Pre-abatement dust ≥ action level→EPA recommends abatement
- Reportable floor wipe: 4 µg/ft²→Hazard below floor action level(Single-surface example)
- Post-abatement floor wipe: 5 µg/ft²→Reclean and retest represented area(Single-surface example)
- Post-abatement four-wipe floor composite→Compare against 2.5 µg/ft² cutoff
- Post-abatement reportable below action levels→Add required abatement report statement
Post-Abatement Checks
- Qualified examiner
- Certified inspector or risk assessor
- Visual before wipes
- Remove deterioration and visible dust/debrisAlso remove visible residue
- Minimum sampling delay
- ≥1 hour after final cleanup
- Floor action level
- 5 µg/ft²
- Interior sill action level
- 40 µg/ft²
- Window trough action level
- 100 µg/ft²
- Single-surface passing result
- Below applicable action level
- Composite cutoff
- Action level ÷ half subsample count
- Four floor subsamples
- Composite cutoff 2.5 µg/ft²
- Result at or above cutoff
- Reclean and retest represented components
- Interior post-abatement locations
- Floor, interior sill, trough if present≥4 spaces, all if fewer
- Interior containment
- Include floor outside containment
- Exterior paint abatement
- Inspect nearby horizontal surfacesRemove dripline paint chips
- Abatement report author
- Certified supervisor or project designer
- Reportable, below action levels
- Required abatement report hazard statement
Common Traps
Paint Content and Paint Hazards
Positive paint identifies lead content ≠ Hazards depend on exposure conditions
Dust Hazard and Clearance
Reportable floor dust identifies hazard ≠ Clearance uses applicable action cutoff
Exact Action Cutoff Fails
Below cutoff passes dust criterion ≠ At cutoff requires retesting
Mixed Component Dust Samples
Floor wipes can share composite ≠ Floors and sills require separate samples
Wipe Mass and Dust Loading
Lab mass in µg ≠ Loading in µg/ft²
Soil Cover Durability
Grass or mulch reduces contact ≠ Pavement provides permanent soil cover
XRF Inconclusive Needs Confirmation
Negative is a classification ≠ Inconclusive needs resolution
Last Minute
- 1.Apply to EPA before testing
- 2.Risk assessments require certified risk assessors
- 3.Screen limits paint and dust sampling
- 4.XRF follows model-specific performance sheet
- 5.Use matrix-recognized NLLAP laboratories
- 6.Reportable floor/sill dust is hazardous
- 7.Clearance: floors <5 µg/ft²
- 8.Clearance: interior sills <40 µg/ft²
- 9.Clearance: window troughs <100 µg/ft²
- 10.Adjust clearance cutoff for composites
- 11.Dust loading uses µg/ft²
- 12.Bare play soil hazard ≥400 ppm
- 13.Non-play hazard: bare-soil mean ≥1,200 ppm
- 14.Give owner report, retain ≥3 years
Explore More EPA Lead Inspector and Risk Assessor
Continue into nearby exams from the same family. Each card keeps practice questions, study guides, flashcards, videos, and articles in one place.
More From This Family
Videos and articles for deeper review.