3.1 Vital Signs Measurement & Normal Ranges
Key Takeaways
Interpret a reading in context. Compare it with the resident’s usual findings and reporting parameters, and get immediate help if the resident has signs of an emergency.
Hot or cold drinks can change an oral temperature reading. Follow the thermometer and facility instructions; MedlinePlus advises waiting 20–30 minutes after a hot or cold drink.
Count radial pulse and respirations for one full minute on the Tennessee skills exam. The pulse reading must be within four beats and the respiration reading within two breaths of the evaluator.
A cuff that is too small can read falsely high. Choose an appropriate cuff and support the bare upper arm at heart level for clinical readings.
Tennessee Skill 23 uses a manual cuff and stethoscope and requires both readings to be within 8 mmHg of the evaluator’s values. Electronic blood pressure Skill 12 is excluded.
3.1 Vital Signs Measurement & Normal Ranges
Vital signs describe temperature, pulse, breathing and blood pressure. Depending on the assignment, a trained aide may also collect oxygen saturation and ask about pain. Explain the procedure, identify the resident, perform hand hygiene and record the actual result. Comparing measurements across time is more useful when the same route, position and equipment are used. The nurse evaluates the findings and decides on care.
Body Temperature Measurement Routes & Baseline Ranges
Temperature varies with activity, time of day, the resident and the measurement route. A resting adult’s oral temperature averages about 98.6°F (37°C). Compare with the resident’s usual reading and report the route. Avoid trying to convert an ear, forehead or axillary reading to an oral reading by adding a fixed number. See MedlinePlus temperature measurement.
| Route | Practical considerations |
|---|---|
| Oral | Use a covered probe under the tongue with lips closed if the resident can cooperate safely. Keep the probe in place per the device instructions. |
| Axillary | If assigned, position the probe in the center of the armpit against skin and have the resident hold the arm against their body until the reading is ready. Document that the route was axillary. |
| Tympanic or temporal | These devices measure infrared radiation from the ear or forehead. Follow the particular thermometer’s instructions for position, probe cover and cleaning. |
| Rectal | Requires additional precautions. If oral measurement is unsafe or the route is unclear, ask the nurse which measurement to take. Use only a method that is assigned and permitted by facility policy. |
Oral temperature after coffee. If the resident finished a hot drink five minutes ago and the temperature is routine, allow the wait specified by the facility and thermometer. MedlinePlus advises waiting 20–30 minutes after smoking, eating or drinking hot or cold liquids. The wait is counted from when the resident finished. For an urgent measurement or a resident unable to use the oral probe safely, alert the nurse and ask about another suitable route.
A correct reading also depends on infection prevention. Apply a clean cover if the device uses one, discard it after use and clean the equipment according to instructions. Report the temperature, route, time and any observed symptoms. For example, chart “oral 98.4°F at 08:30” instead of “temperature normal.”
Radial & Apical Pulse Measurement
The pulse is the pressure wave produced as the heart pumps blood. Note the rate, regularity and strength you observe. For a resting healthy adult, a common reference range is 60–100 beats per minute. A rate below 60 is called bradycardia and one above 100 is tachycardia. Activity, symptoms, medications and the resident’s usual rate matter.
Measure the Radial Pulse
- Support the resident’s arm. Place your index and middle fingertips on the thumb side of their wrist. Use light pressure to feel each beat.
- Count as directed by the care setting. A full minute avoids extrapolation and is especially important when the rhythm is irregular.
- Note the rate and whether the beats feel regular or irregular, strong or weak. Leave the resident safely positioned, clean your hands, and document the result. Report unexpected changes.
Tennessee Skill 6: Explain the measurement and count for a full minute. Leave the call device in reach and perform hand hygiene at the point specified by the checklist before recording. The recorded pulse must be within 4 beats of the evaluator’s reading. For example, 76 beats is a 3-beat difference from 79 and is inside that tolerance.
Other Pulse Sites
The brachial pulse in the bend of the elbow helps locate the blood pressure cuff marker and the place for the stethoscope. An apical pulse is heard over the apex of the heart with a stethoscope, usually near the adult’s left fifth intercostal space at the midclavicular line. Record the measurement site and report a new irregular pulse. Ask the nurse about any measurement outside your assigned competency. An apical–radial deficit is a difference between apical and radial counts obtained at the same time. It calls for nursing evaluation.
Respiration Rate & Characteristics Assessment
One respiration is a complete inhale and exhale. Observe breathing rate, effort and pattern. Resting adult reference ranges vary somewhat by source. MedlinePlus gives 12–18 breaths per minute for an average healthy adult at rest. A resident can need help despite a count within a usual reference range.
- Apnea is absence of breathing. Activate emergency response when a resident becomes unresponsive and is not breathing normally. Follow the facility’s response procedure, your training and applicable resuscitation orders.
- Dyspnea is difficult or uncomfortable breathing. Report new trouble breathing promptly and activate help for severe distress.
- Tachypnea and bradypnea mean faster and slower breathing than expected. Report the actual count and what you see.
- Cheyne–Stokes breathing has cycles of deeper then shallower breathing with pauses. Report an unexpected pattern. For comfort care, follow the resident’s plan and notify the nurse of changes.
Count Respirations at Rest
Explain that you are taking vital signs. After counting the pulse, you can keep your fingers at the wrist while observing the rise and fall of the chest so the resident can breathe naturally. Count one rise-and-fall cycle as one breath. Record the rate, regularity and signs of extra effort.
Tennessee Skill 7: Explain the test procedure as required, then count for one full minute. The reading must be within 2 breaths of the evaluator’s count. Leave the signaling device within reach and perform hand hygiene before recording, as directed on the skill checklist.
Blood Pressure Measurement & Error Prevention
Blood pressure is recorded in millimeters of mercury (mmHg). The upper number (systolic) is the pressure during the heart’s contraction. The lower number (diastolic) is the pressure between beats. Record both numbers with the time and, according to policy, the position and arm.
What the Adult Blood Pressure Categories Mean
The 2025 AHA/ACC guideline classifies adult readings as follows. These categories describe readings; diagnosis and treatment are clinical decisions. If the two numbers indicate different categories, the higher category applies.
| Category | Systolic | Relationship | Diastolic |
|---|---|---|---|
| Normal | Below 120 | And | Below 80 |
| Elevated | 120–129 | And | Below 80 |
| Stage 1 | 130–139 | Or | 80–89 |
| Stage 2 | 140 or higher | Or | 90 or higher |
For example, 126/84 falls in the stage 1 range because of the diastolic value. A reading above 180 systolic or above 120 diastolic with chest pain, difficulty breathing, weakness or other concerning symptoms needs emergency response. Notify the nurse promptly of a very high reading without symptoms. A sudden drop with dizziness or fainting also needs prompt help, even if the value does not cross a preset threshold.
Choose a Cuff and Position the Resident
For routine measurements, when possible, allow the resident to rest quietly before the measurement. Seat the resident with back supported, feet flat and legs uncrossed. Support the bare arm at heart level. If you use another position per the care plan, record it as required. Ask the nurse which arm to use if the resident has an access site such as a dialysis fistula, has surgery-related precautions, or has an injury or equipment affecting cuff placement.
Select by the manufacturer’s arm circumference range. A cuff that is too small can read falsely high and one that is too large can read falsely low. Place the cuff’s marker over the brachial artery. A misplaced cuff or unsupported arm can also shift the reading.
Manual Blood Pressure in Clinical Practice
If trained and assigned to use a manual cuff, follow the facility’s protocol. A palpated estimate helps guide inflation. Identify the radial pulse, inflate the cuff and note the pressure at which the pulse disappears. Deflate completely. Then place the stethoscope over the brachial artery, inflate about 20–30 mmHg above the estimated systolic pressure and release pressure slowly, about 2 mmHg per second. Note the first repeated tapping sound for systolic pressure and the disappearance of the sounds for diastolic pressure. Record the observed values according to policy. If you cannot obtain a reliable reading, tell the nurse rather than guessing. See the AHA measurement statement.
Tennessee Skills Exam: Manual Blood Pressure
Use the Tennessee Skill 23 checklist for the demonstration. It specifies 160–180 mmHg initial inflation and, if a beat is heard immediately on deflation, full deflation before reinflating to no more than 200 mmHg. For the exam, when rounding is needed, round up to the next 2-mmHg mark. Each of the systolic and diastolic entries must be within 8 mmHg of the evaluator’s result. For an evaluator reading of 122/76, a recorded 128/86 meets the systolic tolerance (+6) but misses the diastolic tolerance (+10). Electronic BP Skill 12 is excluded in Tennessee.
Report Changes Clearly
- Use the care plan: Learn the resident’s reporting parameters and expected baseline. Report results outside the parameters, measurements you cannot obtain and changes that matter, including a new irregular pulse or a developing temperature rise.
- Get help promptly: Activate the appropriate facility response for serious symptoms such as new severe breathing difficulty, chest pain or unresponsiveness. Do not delay the call to obtain a complete set of measurements.
- Check conditions when safe: A cuff mismatch, movement, cold fingers or a poorly seated oximeter can affect a reading. Pulse oximetry estimates oxygen saturation and accuracy can vary, including with skin pigmentation or poor circulation. Report the reading and symptoms together. A device number by itself cannot rule out distress.
A resident finished hot coffee five minutes ago. The facility uses the MedlinePlus oral temperature guidance, and the reading is routine. What should the CNA do?
Wait until 20–30 minutes have elapsed since the resident finished drinking, then measure orally as assigned.
Take an axillary reading immediately and add two degrees.
Take the oral reading immediately and chart it as an accurate baseline.
Give ice water before placing the probe.
A resident’s upper arm measures outside the recommended range of the cuff because the cuff is too small. What is the likely effect on the blood pressure reading?
It is falsely low.
It can be falsely high.
It is accurate if the cuff is moved toward the wrist.
Only the pulse rate changes.
For Tennessee Skill 7, why should the resident breathe naturally after the aide explains the measurement and quietly observes the chest?
Breathing is measured by counting each rise and fall separately.
The evaluator scores an average made from two 15-second counts.
Trying to control each breath can change the resting rate the aide is measuring.
The aide must start an apical pulse check to count breaths.
Sections you finish are checked off in the contents.