4.3 Mechanical Ventilation Troubleshooting & Sepsis Resuscitation

Key Takeaways

  • Assess the patient first when a ventilator alarms and support ventilation urgently when it fails.

  • High pressure suggests obstruction or reduced compliance. Low pressure or volume suggests a leak, disconnection or displacement.

  • SSC 2026 uses the one-hour antimicrobial goal for shock or probable or definite sepsis. Possible sepsis without shock has a rapid reassessment pathway.

  • For adult septic shock or sepsis-induced hypoperfusion, 30 mL/kg within three hours is an initial crystalloid recommendation with frequent individualised reassessment.

  • Norepinephrine is usually first-line, with an initial adult MAP goal of 65 mmHg and a context-specific range in older adults.

Last updated: November 2026

Mechanical Ventilation Alarm Troubleshooting

Assess the patient first. Observe chest rise, breathing effort, skin colour, oxygen saturation, heart rate and blood pressure. Look for a readily corrected circuit problem while calling for help. If ventilation through the machine is failing and the cause cannot be corrected rapidly, a trained clinician supports ventilation with a manual bag and oxygen while the team evaluates tube position, obstruction, lung problems and equipment. When the tube may be displaced, assess airway position and use appropriate backup ventilation rather than ventilating through an unverified tube. Bagging can provide temporary support, but its response is only one clue to the cause.

High-Pressure vs. Low-Pressure Ventilator Alarms

Alarm TypeUnderlying MechanismCommon Bedside CausesImmediate Nursing Interventions
High-Pressure AlarmIncreased airway resistance or decreased lung/chest wall complianceAirway secretions / mucus plug; kinked tubing or water condensate; biting the endotracheal tube (ETT); bronchospasm; coughing; pneumothorax; right mainstem migrationAssess chest rise and auscultate; suction airway (preoxygenate, use sterile technique for open suction, and limit suction to 15 seconds); straighten kinks and drain condensate; address biting according to protocol, give prescribed bronchodilator if indicated, and urgently assess possible tension pneumothorax
Low-Pressure / Low-Volume AlarmLoss of circuit pressure or air escaping systemVentilator circuit disconnection; ETT cuff leak or damaged pilot balloon; accidental extubation / displacement; large chest drain leakTrace circuit from patient to ventilator and reconnect; check cuff pressure (20–30 cmH2O20\text{–}30\text{ cmH}_2\text{O}) and listen for vocalisation/oral air leak; verify ETT centimetre mark at teeth; call for airway help and support ventilation via a verified airway or appropriate backup route if displaced

Key Nursing Details for Airway Suctioning and Cuff Safety

  • Suctioning on demand, not routinely: Perform endotracheal suctioning when indicated by findings such as visible secretions, new coarse breath sounds suggesting retained secretions or a sawtooth ventilator waveform. Preoxygenate, use shallow suction first, use sterile technique for open suctioning and limit suction to 15 seconds. Monitor the response and avoid routine saline instillation.
  • Pneumothorax on positive-pressure ventilation: Positive pressure accelerates tension pneumothorax development. If a high-pressure alarm coincides with sudden hypotension, tachycardia, falling SpO2\text{SpO}_2, and unilateral absent breath sounds, activate the emergency response and prepare for urgent assessment and decompression if tension pneumothorax is suspected.
  • Cuff pressure management: Maintain ETT cuff pressure between 20 and 30 cmH2O\text{cmH}_2\text{O}. Under-inflation (<20 cmH2O< 20\text{ cmH}_2\text{O}) risks low-pressure alarms and microaspiration (ventilator-associated pneumonia), while over-inflation (>30 cmH2O> 30\text{ cmH}_2\text{O}) causes tracheal mucosal ischaemia.

Surviving Sepsis and Septic Shock Resuscitation

Sepsis is life-threatening organ dysfunction caused by a dysregulated host response to infection. Septic shock is a severe subset characterised by profound circulatory and cellular/metabolic abnormalities: persistent hypotension requiring vasopressors to maintain mean arterial pressure (MAP) ≥65 mmHg\ge 65\text{ mmHg} AND serum lactate >2 mmol/L> 2\text{ mmol/L} despite adequate volume resuscitation.

Adult Sepsis and Septic Shock: 2026 International Recommendations

Begin resuscitation and diagnostic assessment together. The Surviving Sepsis Campaign (SSC) 2026 adult guideline distinguishes definite, probable and possible sepsis, and whether shock is present. Use a separate age- and setting-specific pathway in children or newborns.

  1. Assess perfusion and obtain samples. Measure lactate and trend it when elevated or when shock is present. An elevated lactate can reflect several processes. Interpret it alongside capillary refill, mental status, BP, urine output and the overall clinical picture. Collect blood cultures promptly and ideally before antimicrobials. Do not let difficulty obtaining samples delay urgent therapy.
  2. Start appropriate IV antimicrobials early. Give immediately, ideally within one hour, for possible, probable or definite septic shock and probable or definite sepsis without shock. If sepsis is only possible and there is no shock, assess rapidly and give within three hours of first suspicion if concern for infection persists. Choose empiric treatment by suspected source, local resistance, allergies and individual risk. Review cultures, look for a source requiring urgent control and reassess the regimen.
  3. Restore perfusion. For adult sepsis-induced hypoperfusion or septic shock, SSC suggests at least 30 mL/kg IV crystalloid in the first three hours, with reassessment and adjustment for individual characteristics. Balanced crystalloid is generally favoured for initial resuscitation. Give and reassess on the clinical timeline. Observe dynamic measures of response when available and watch for pulmonary congestion or ongoing shock.
  4. Use vasopressors promptly when needed. Norepinephrine is the usual first-line agent. For unstable shock it can be started concurrently with fluid resuscitation when warranted. Follow the local peripheral vasopressor protocol if central access would delay needed support. The general adult initial MAP target is 65 mmHg. In patients at least 65 years old, SSC conditionally suggests an initial range of 60–65 mmHg. Reassess organ perfusion and titrate under the treatment plan.

Worked Calculation Example: Septic Shock Fluid Bolus and MAP

A 54-year-old, 70 kg woman with suspected urinary-source septic shock presents with blood pressure 82/48 mmHg, heart rate 124 beats/min, temperature 39.1∘C39.1^\circ\text{C}, and serum lactate 4.6 mmol/L4.6\text{ mmol/L}. First calculate her MAP:

MAP=SBP+2(DBP)3=82+2(48)3=1783≈59 mmHg\text{MAP} = \frac{\text{SBP} + 2(\text{DBP})}{3} = \frac{82 + 2(48)}{3} = \frac{178}{3} \approx 59\text{ mmHg}

Her estimated MAP is below the general adult initial target. The team draws cultures without delaying antimicrobials and begins resuscitation. The 30 mL/kg example corresponds to:

30 mL/kg×70 kg=2,100 mL isotonic crystalloid30\text{ mL/kg} \times 70\text{ kg} = 2{,}100\text{ mL isotonic crystalloid}

Weight-based arithmetic helps prepare the fluids. It does not require giving the whole amount as one bolus. If her BP is still 86/50 mmHg86/50\text{ mmHg} (estimated MAP 62 mmHg) during resuscitation with ongoing hypoperfusion, the team reassesses fluid responsiveness and starts norepinephrine when indicated, titrating toward the initial MAP goal and monitoring organ perfusion.

AARC artificial airway suctioning guideline · AARC patient–ventilator assessment · Surviving Sepsis Campaign adult guideline, 2026

Loading diagram...
Bedside Mechanical Ventilator Alarm Troubleshooting Algorithm
Test Your Knowledge

An intubated ICU patient's ventilator suddenly triggers a continuous high-pressure alarm, SpO2 drops from 97% to 88%, and air entry is bilateral with coarse sounds and visible secretions in the ETT. What is the nurse's most appropriate action?

A

Check the ETT cuff pressure with a manometer because high-pressure alarms indicate a cuff leak

B

Assess the patient, call for assistance as needed, preoxygenate and suction the endotracheal tube

C

Silence the alarm and increase the high-pressure alarm limit by 15 cmH2O

D

Disconnect the patient permanently and leave them on a nasal cannula

Test Your Knowledge

Which combination of findings is most likely to trigger a LOW-pressure alarm on a mechanical ventilator?

A

Severe bronchospasm and mucus plugging

B

Patient biting the endotracheal tube while waking from sedation

C

A disconnected ventilator circuit or ruptured endotracheal tube cuff

D

Development of a right-sided tension pneumothorax

Test Your Knowledge

A 52-year-old adult weighing 80 kg has a blood pressure of 80/44 mmHg (MAP 56 mmHg) and serum lactate of 4.8 mmol/L. Two sets of blood cultures are drawn, broad-spectrum IV antibiotics are started within 40 minutes, and MAP remains 58 mmHg during reassessed IV crystalloid resuscitation. He has ongoing signs of poor perfusion. Which vasopressor should be initiated first?

A

Norepinephrine titrated toward an initial MAP of 65 mmHg

B

Dopamine infusion titrated to achieve systolic blood pressure above 140 mmHg

C

Oral midodrine combined with immediate 20% mannitol

D

IV furosemide to stimulate urine output before any vasopressor

Sections you finish are checked off in the contents.