7.1 Pediatric Invasive Mechanical Ventilation: Modes, Triggering, Cycling & Waveforms

Key Takeaways

  • Measure plateau pressure during a passive inspiratory hold and total PEEP during an expiratory hold. Use total PEEP for static driving pressure and compliance.

  • The passive model uses resistance times compliance for the time constant. Check units and compare the model with actual expiratory flow and measured pressures.

  • Volume control sets volume delivery, pressure control sets inspiratory pressure, and PRVC adjusts pressure between breaths toward a volume target. Confirm delivered volume and patient effort in any mode.

  • In PARDS, PALICC-2 uses the lesser of predicted and actual body weight. Use 6–8 mL/kg initially and lower volume when needed to meet pressure limits.

  • Use waveform changes as clues and verify them at the bedside. Cardiac oscillations can trigger breaths in either pressure or flow triggering.

Last updated: November 2026

Pediatric invasive mechanical ventilation

Choose settings based on the child's respiratory mechanics, gas exchange and circulation. Check delivered tidal volume and pressure after changing settings or modes. Read the ventilator graphics with the examination, the airway and the circuit.

Pressure, volume and flow

In a simplified single-compartment model, the airway pressure delivered by the ventilator plus the pressure generated by inspiratory muscle effort balances the elastic and resistive loads above total end-expiratory pressure.

Paw+Pmus=VCrs+RrsV˙+PEEPtotP_{aw}+P_{mus}=\frac{V}{C_{rs}}+R_{rs}\dot V+PEEP_{tot}

Here VV is volume above the end-expiratory starting volume, V˙\dot V is flow, CrsC_{rs} is respiratory system compliance, and RrsR_{rs} is effective resistance. Use liters and liters per second with compliance in L/cm H₂O and resistance in cm H₂O/(L/s). This approximation assumes linear mechanics and neglects inertance. The lung and chest wall both contribute to compliance. Small tubes, secretions, kinking and bronchospasm can increase the resistive load. Mechanical ventilation taxonomy and equation of motion · Pediatric respiratory mechanics measurements

MeasurementHow to use it
Plateau pressure and static complianceMeasure plateau pressure during an end-inspiratory hold with no flow and a passive patient. Static driving pressure is plateau minus total PEEP. Static compliance is tidal volume divided by that difference. A leak or respiratory effort can distort the hold.
Total and intrinsic PEEPIn a passive patient, use an end-expiratory hold to estimate total PEEP. Subtract set PEEP to estimate intrinsic PEEP. A hold samples communicating units and may miss regional trapping.
Peak pressure and dynamic complianceIn comparable breaths, tidal volume divided by peak pressure minus total PEEP gives a dynamic estimate influenced by resistance as well as elastic load. A changing peak-to-plateau gap calls for an airway and circuit check and comparison at the same flow.
Inspiratory resistance estimateWith passive constant-flow volume control, divide peak pressure minus plateau pressure by the measured inspiratory flow. This effective estimate includes the artificial airway and can include viscoelastic effects. It does not isolate bronchial resistance.

Worked example: With tidal volume 120 mL, peak pressure 28, plateau 22, set PEEP 6 and total PEEP 8 cm H₂O, intrinsic PEEP is 2 cm H₂O. Static driving pressure is 14 cm H₂O, and static compliance is 120/14≈8.6120/14\approx8.6 mL/cm H₂O. With constant inspiratory flow 0.25 L/s, estimated inspiratory resistance is (28−22)/0.25=24(28-22)/0.25=24 cm H₂O/(L/s). AARC patient–ventilator assessment · Pediatric PARDS pressure study

Expiratory time constant

In a passive single-compartment model, the time constant is τ=R×C\tau=R\times C. The proportion of the initial volume change completed by time tt is 1−e−t/τ1-e^{-t/\tau}. At one, two, three and five time constants this is approximately 63.2%, 86.5%, 95.0% and 99.3%. Convert mL to L before multiplying by resistance expressed per L/s.

The model assumes a single resistance and compliance. Children with obstruction may have uneven regional time constants and different inspiratory and expiratory resistance. A calculation using an inspiratory resistance estimate may understate the time needed to exhale. Persistent flow at the next inspiration suggests incomplete emptying. Check for leaks and effort, measure total PEEP when feasible and reassess after allowing more expiratory time. Clinical study of expiratory time constants · Infant bronchiolitis mechanics study

Mode and breath timing

ModeWhat the ventilator controlsWhat to monitor
Volume controlTargets set tidal volume with a defined inspiratory flow delivery pattern.Pressure changes with mechanics and effort. Confirm exhaled volume and check leaks, pressure limits and circuit compensation.
Pressure controlDelivers a set inspiratory pressure for a set time. Flow usually decelerates. Check whether the machine displays pressure above PEEP or total inspiratory pressure.Tidal volume changes with mechanics, inspiratory time, leaks and effort. A pressure limit alone cannot establish lung protection.
Pressure-regulated volume control (PRVC)Uses pressure-controlled breaths and adapts inspiratory pressure between breaths toward a volume target.Verify delivered volume, pressure and effort. Larger breaths from vigorous patient effort can make the ventilator reduce pressure on subsequent breaths. Reassess support when effort or leaks change.

For PARDS, PALICC-2 suggests 6–8 mL/kg of the lesser of predicted and actual body weight. Use 4–6 mL/kg when needed for pressure limitation, with caution below 4 mL/kg. In most children with PARDS the suggested plateau limit is 28 cm H₂O and static driving pressure limit is 15 cm H₂O. Reduced chest-wall compliance may permit a higher plateau under the guideline. For an actual weight of 32 kg and a predicted weight of 24 kg, 6 mL/kg is 144 mL. Reassess measured mechanics, gas exchange and circulation. Postoperative cardiac physiology may change the tolerance of airway pressure. Getinge Servo-u manual · Pediatric PRVC study · PALICC-2 · AAP neonatal cardiac respiratory care

Triggering starts inspiration. A ventilator can trigger based on time, or detect an inspiratory pressure drop or flow change from the child. If breaths occur without effort, inspect the circuit for condensate, check for leaks and compare pressure or flow deflections with the cardiac rhythm. Cardiac oscillations can trigger breaths in pressure and flow modes. Adjust sensitivity or trigger method as appropriate for the device and verify that true patient efforts still trigger breaths.

Cycling ends inspiration. Pressure-controlled mandatory breaths usually cycle by time. Pressure support usually cycles when inspiratory flow falls to a set fraction of peak. For example, at a peak of 20 L/min, a 25% threshold is 5 L/min. A higher percentage usually cycles earlier, which can help when expiration starts before the machine cycles. A lower percentage usually cycles later. Interpret the setting with the patient's effort, leak and expiratory time. Ventilator taxonomy · Manufacturer controls · Cardiac oscillation studies · Trigger bench study

Reading graphics at the bedside

  • Flow–time: Expiratory flow continuing into inspiration suggests trapping. Confirm the cause and assess expiratory time, measured PEEP and hemodynamics. A sawtooth tracing can accompany secretions. Also check for circuit water and confirm the clinical indication for suction.
  • Pressure–time: During constant-flow volume control, an inspiratory dip with visible effort can suggest unmet flow demand. Check settings, respiratory drive and discomfort. A single contour can have more than one explanation.
  • Pressure–volume loop: End-inspiratory flattening, with pressure on the horizontal axis, suggests decreasing compliance and possible overdistension. Compare tidal volume, plateau pressure and driving pressure. The lower inspiratory inflection does not establish the pressure that prevents collapse on deflation. In PARDS, adjust PEEP using oxygenation, oxygen delivery, compliance and hemodynamics rather than adding a fixed amount to a loop landmark. PALICC-2 monitoring · AARC suction guideline · Pressure–volume and CT study
Loading diagram...
Pediatric Ventilator Waveform & Graphic Analysis Diagnostic Pathway
Test Your Knowledge

An 8 kg infant with severe bronchiolitis is passively ventilated at 36 breaths/min, inspiratory time 0.6 seconds and set PEEP 6 cm H₂O. Expiratory flow persists at the next breath. An expiratory hold gives total PEEP 13 cm H₂O. Use an estimated resistance of 60 cm H₂O/(L/s) and compliance of 0.8 mL/cm H₂O per kg in a single-compartment model. Which interpretation and next step fit?

A

The estimated time constant is 0.38 seconds. Allow more expiratory time, for example by lowering the rate, and recheck the tracing, total PEEP and ventilation.

B

The time constant is 3.8 seconds. Increase the respiratory rate to clear the trapped volume.

C

The measured intrinsic PEEP is 13 cm H₂O. Lengthen inspiration at the same rate to allow more time for exhalation.

D

The tracing confirms fixed tracheal stenosis. Extubate immediately to high-flow nasal cannula.

Test Your Knowledge

A 5-year-old child with PARDS from bacterial pneumonia weighs 20 kg, which is also the predicted body weight. During passive volume-controlled ventilation, tidal volume is 160 mL, total PEEP is 8 cm H₂O, peak pressure is 36 cm H₂O and plateau pressure is 32 cm H₂O. Chest-wall compliance is normal. The pressure–volume loop flattens near end inspiration. Which interpretation and action best fit these findings?

A

Treat a presumed endotracheal tube plug with suction alone.

B

The findings suggest overdistension. Reduce tidal volume and reassess plateau and driving pressures, oxygenation and ventilation.

C

Treat presumed unmet inspiratory flow demand by increasing peak inspiratory flow.

D

Increase extrinsic PEEP immediately because end-inspiratory flattening establishes derecruitment.

Test Your Knowledge

A postoperative infant has extra ventilator breaths above the set backup rate. The team sees no inspiratory effort preceding the extra breaths. Small pressure and flow deflections that trigger them coincide with cardiac pulsations. The tube and circuit checks show no significant leak or condensate. What is the most likely explanation and initial ventilator response?

A

Central hyperventilation. Increase sedation before checking the trigger.

B

A software fault. Replace the ventilator without testing the trigger.

C

Cardiogenic auto-triggering. Adjust trigger sensitivity or method on this device and confirm that real efforts still trigger breaths.

D

Tension pneumothorax. Decompress the left chest based solely on the elevated displayed rate.