2.5 VLAN Configuration, Verification & Troubleshooting
Key Takeaways
Verification of Junos VLAN operations requires multi-layer inspection using 'show vlans detail', 'show ethernet-switching interfaces', and 'show arp'.
Native VLAN mismatches can place untagged traffic in different broadcast domains at opposite ends; standard RSTP does not negotiate native VLAN IDs.
If an active VLAN is omitted from the trunk's 'vlan members' allowed list, the switch silently discards that VLAN's frames at the Layer 2 ingress pipeline without generating interface errors.
A structured troubleshooting workflow maps symptoms—such as unreachable gateways or intermittent packet loss—to Layer 1 physical faults, Layer 2 tag mismatches, or Layer 3 IRB binding omissions.
Duplex mismatches resulting from disabled auto-negotiation cause late collisions, frame check sequence (FCS) errors, and severe application throughput degradation.
Enterprise Multi-VLAN Configuration Template
To establish a baseline for enterprise switching operations and troubleshooting, consider the following end-to-end configuration template for a Junos Enhanced Layer 2 Software (ELS) switch. This template incorporates distinct corporate data, voice, guest, and native transit VLANs, configured alongside access edge ports, 802.1Q trunk uplinks, and Integrated Routing and Bridging (IRB) Layer 3 interfaces.
[edit]
# 1. Define Layer 2 VLANs
set vlans DATA-CORP vlan-id 10
set vlans VOICE-CORP vlan-id 20
set vlans GUEST-NET vlan-id 30
set vlans NATIVE-TRANSIT vlan-id 99
# 2. Bind Layer 3 IRB Interfaces to VLANs
set vlans DATA-CORP l3-interface irb.10
set vlans VOICE-CORP l3-interface irb.20
set vlans GUEST-NET l3-interface irb.30
# 3. Configure Layer 3 Gateway IP Addresses
set interfaces irb unit 10 description "Default Gateway - Corporate Data"
set interfaces irb unit 10 family inet address 10.10.10.1/24
set interfaces irb unit 20 description "Default Gateway - Corporate Voice"
set interfaces irb unit 20 family inet address 10.10.20.1/24
set interfaces irb unit 30 description "Default Gateway - Guest Wi-Fi"
set interfaces irb unit 30 family inet address 172.16.30.1/24
# 4. Configure Inter-Switch 802.1Q Trunk Uplink
set interfaces ge-0/0/0 description "Trunk Uplink to Distribution Switch"
set interfaces ge-0/0/0 native-vlan-id 99
set interfaces ge-0/0/0 unit 0 family ethernet-switching interface-mode trunk
set interfaces ge-0/0/0 unit 0 family ethernet-switching vlan members [ DATA-CORP VOICE-CORP GUEST-NET NATIVE-TRANSIT ]
# 5. Configure User Edge Access Port with Voice VLAN & LLDP-MED
set interfaces ge-0/0/1 description "Workstation + IP Phone Access Port"
set interfaces ge-0/0/1 unit 0 family ethernet-switching interface-mode access
set interfaces ge-0/0/1 unit 0 family ethernet-switching vlan members DATA-CORP
set switch-options voip interface ge-0/0/1.0 vlan VOICE-CORP
set switch-options voip interface ge-0/0/1.0 forwarding-class expedited-forwarding
set protocols lldp interface ge-0/0/1
set protocols lldp-med interface ge-0/0/1
Essential Monitoring & Verification Commands
Troubleshooting Layer 2 and Layer 3 switching issues in Junos requires mastering four fundamental CLI verification commands:
1. show vlans and show vlans detail
The primary command to verify VLAN status, 802.1Q tags, and interface associations across the switch fabric:
user@EX4400> show vlans detail
VLAN: DATA-CORP, Shared VLAN ID: 0, Tag: 10, State: Active
Active interfaces:
ge-0/0/0.0 (tagged)
ge-0/0/1.0 (untagged)
Layer 3 interface: irb.10
VLAN: GUEST-NET, Shared VLAN ID: 0, Tag: 30, State: Inactive
Active interfaces:
none
Layer 3 interface: irb.30
Operational Analysis:
- State: Active vs. Inactive: A VLAN is marked
Activeonly when at least one assigned physical or aggregated interface is in the operationalupstate. Notice thatGUEST-NETdisplaysState: Inactivebecause no active interfaces belong to it (Active interfaces: none). - Impact on IRB: When a VLAN transitions to
Inactive, its bound IRB interface remains operationally down (Link: Down), preventing the switch from routing traffic for that subnet or responding to local pings.
2. show ethernet-switching interfaces
Displays the operational port mode, native VLAN ID, active VLAN memberships, and Spanning Tree Protocol (STP) state for every switched port on Junos ELS switches:
user@EX4400> show ethernet-switching interfaces
Interface State VLAN members Tag Tagging Blocking
ge-0/0/0.0 up DATA-CORP 10 tagged Forwarding
VOICE-CORP 20 tagged Forwarding
NATIVE-TRANSIT 99 untagged Forwarding
ge-0/0/1.0 up DATA-CORP 10 untagged Forwarding
VOICE-CORP 20 tagged Forwarding
Operational Analysis:
- Inspect the Tagging column: On trunk port
ge-0/0/0.0,NATIVE-TRANSITis listed asuntagged, illustrating a trunk explicitly configured for untagged native egress; verify that behavior on the actual platform. On access portge-0/0/1.0,DATA-CORPisuntaggedwhileVOICE-CORPistagged. - Inspect the Blocking column: If Spanning Tree has blocked a port to prevent a bridging loop, the state displays
DiscardingorBlocking, explaining why all frame transmission has halted on that link.
3. show arp
Inspects Layer 3 IPv4-to-MAC resolution on IRB routing interfaces:
user@EX4400> show arp
MAC Address Address Name Interface Flags
aa:aa:aa:11:11:11 10.10.10.50 host-a.corp irb.10 none
00:05:86:71:00:01 10.10.10.1 switch-gw irb.10 permanent
incomplete 172.16.30.45 guest-tablet irb.30 none
Operational Analysis:
- A flag of
noneindicates dynamically resolved ARP entries. - An entry displaying
incompleteindicates the switch issued an ARP request for the target IP address out the designated IRB interface, but received no ARP reply. This occurs when the client is powered off, firewalled against ARP, or connected to a port assigned to the wrong VLAN.
4. show ethernet-switching table
Displays the switch's Layer 2 Filtering Database (MAC address table):
user@EX4400> show ethernet-switching table
Ethernet switching table : 3 entries, 3 learned
Routing instance : default-switch
VLAN MAC address Type Age Interfaces
DATA-CORP aa:aa:aa:11:11:11 Learn 0 ge-0/0/1.0
VOICE-CORP cc:cc:cc:33:33:33 Learn 12 ge-0/0/1.0
DATA-CORP b8:bb:bb:22:22:22 Learn 5 ge-0/0/0.0
Operational Analysis: If a MAC rapidly alternates between ports, investigate a Layer 2 loop, host mobility, multihoming, or spoofing. MAC flapping is evidence to investigate, not proof of one cause.
Common Exam Traps & Troubleshooting Scenarios
Trap 1: Native VLAN Mismatch across Trunk Links
A classic enterprise misconfiguration occurs when two interconnected switches are configured with mismatched native VLAN IDs on their interconnecting trunk port:
- Switch-01:
set interfaces ge-0/0/0 native-vlan-id 10 - Switch-02:
set interfaces ge-0/0/0 native-vlan-id 20
Failure Mechanism: If Switch-01’s egress configuration transmits VLAN 10 frames untagged across the trunk, Switch-02 receives them untagged and immediately assigns them to its local native VLAN (VLAN 20). As a result, traffic leaks between unrelated broadcast domains, creating a major security violation.
Verification: Standard RSTP BPDUs do not carry a native-VLAN negotiation TLV. A mismatched native VLAN can misclassify untagged user traffic without RSTP reporting a PVID inconsistency. Compare native-vlan-id and allowed membership on both ends, and inspect ingress/egress tagging. Do not rely on a spanning-tree alarm to enforce VLAN consistency.
Trap 2: Trunk Pruning Drops (Missing VLAN in Allowed List)
An engineer provisions a new VLAN (e.g., VLAN 40, DEV-OPS) on both access and distribution switches, but forgets to update the trunk allowed list on the interconnecting link:
user@EX4400# set interfaces ge-0/0/0 unit 0 family ethernet-switching vlan members [ DATA-CORP VOICE-CORP ]
# Missing DEV-OPS!
Diagnostic Gotcha:
Frames tagged with VLAN 40 arriving at trunk port ge-0/0/0 are dropped immediately by the PFE ingress parser. However, running show interfaces ge-0/0/0 shows zero input errors, zero CRC errors, and normal link carrier! The physical port appears perfectly healthy because the frames are structurally valid Ethernet; the drop occurs purely at the Layer 2 parser level. Only running show ethernet-switching interfaces ge-0/0/0 detail will reveal that VLAN 40 is absent from the active membership list.
Trap 3: Missing l3-interface Association
An administrator configures interfaces irb unit 20 family inet address 10.10.20.1/24, but omits set vlans VOICE-CORP l3-interface irb.20 under the vlans hierarchy.
Symptom & Root Cause:
Hosts in VLAN 20 cannot reach their default gateway (10.10.20.1) or any remote subnets. When viewing show interfaces terse irb.20, do not assume an operationally up IRB proves the VLAN association is correct. However, running show vlans VOICE-CORP detail reveals:
Layer 3 interface: none
Because the IRB interface is not bound to the Layer 2 broadcast domain, the switch never binds its MAC address to VLAN 20 and ignores all incoming ARP requests for 10.10.20.1.
Trap 4: Port Assigned to Wrong Access VLAN
A technician connects a new workstation to port ge-0/0/5. The client receives an IP address in the 172.16.30.0/24 range instead of the corporate 10.10.10.0/24 range, and cannot access internal databases. Running show ethernet-switching interfaces ge-0/0/5 immediately reveals VLAN members: GUEST-NET instead of DATA-CORP. The fix is a simple reassignment under family ethernet-switching vlan members.
Trap 5: Duplex and Speed Mismatches
When connecting a switch trunk or server port, an administrator hardcodes the switch port to speed 100m and link-mode full-duplex, while leaving the connecting endpoint configured for auto-negotiation.
IEEE 802.3u Rule: Under IEEE 802.3u auto-negotiation rules, if a port fails to receive auto-negotiation FLP (Fast Link Pulses) from its partner, it utilizes parallel detection. Parallel detection can reliably detect speed (100 Mbps), but standard rules mandate that duplex must fall back to half-duplex.
Symptom:
One side operates at full-duplex while the other operates at half-duplex. Under light traffic, pings succeed. However, when large data transfers commence, the full-duplex end transmits while the half-duplex end is sending, triggering collisions on the half-duplex port. Running show interfaces ge-0/0/0 extensive reveals mounting Late Collisions and FCS / CRC Errors, severely degrading application performance.
Comprehensive Troubleshooting Reference
| Symptom / Failure | Probable Root Cause | Verification CLI Command | Junos CLI Remediation |
|---|---|---|---|
| Hosts in VLAN cannot ping default gateway; remote routing fails | IRB logical unit is not bound to the VLAN hierarchy | show vlans detail (Inspect Layer 3 interface) | set vlans <vlan-name> l3-interface irb.<unit> followed by commit |
| VLAN traffic fails to cross trunk link; no errors on physical port | VLAN is missing from the trunk's vlan members allowed list | show ethernet-switching interfaces <if-name> | set interfaces <if-name> unit 0 family ethernet-switching vlan members <vlan-name> |
| Untagged traffic enters the wrong VLAN across a trunk | Native VLAN ID mismatch between interconnected switches | show ethernet-switching interfaces (Compare native VLAN on both sides) | Configure identical native-vlan-id <id> and matching vlan members on both switches |
| High packet loss during file transfers; late collisions incrementing | Duplex mismatch (one side hardcoded full, partner auto-negotiating) | show interfaces <if-name> extensive (Look for late collisions & duplex) | Set both sides to auto-negotiate, or hardcode matching speed and link-mode on both ends |
| IRB interface reports Down/Down; cannot route traffic | All physical ports assigned to the VLAN are unplugged or down | show vlans <vlan-name> (Inspect State: Inactive) | Ensure at least one physical access or trunk member port is administratively and operationally up |
Output note: Command output shown here is a schematic teaching example, not a captured device session. Field names and feature support depend on platform and Junos release.
A network engineer discovers that hosts connected to access ports in VLAN 20 cannot reach their default gateway at 10.20.0.1. Running 'show interfaces terse irb.20' shows the logical unit is configured. Running 'show vlans detail' reveals 'Layer 3 interface: none' under VLAN 20. What command resolves the issue?
set interfaces irb unit 20 family ethernet-switching vlan members VOICE-CORP
set vlans VOICE-CORP l3-interface irb.20
set interfaces irb unit 20 mac-address 00:05:86:71:00:01
set protocols rstp interface irb.20 mode access
Switch A (native-vlan-id 10) and Switch B (native-vlan-id 20) are connected by an 802.1Q trunk link. Switch A sends VLAN 10 native traffic untagged, and both switches run standard RSTP. What is the primary network consequence of this configuration?
The switches negotiate the lower native VLAN ID (VLAN 10) automatically using LLDP-MED.
Junos commits a syntax error on Switch B because native VLAN IDs must be globally unique across the autonomous system.
All tagged frames traversing the trunk are dropped, while untagged frames are converted to VXLAN packets.
Untagged traffic sent as native VLAN 10 by Switch A is classified into native VLAN 20 by Switch B; standard RSTP does not automatically detect this mismatch.
An administrator adds VLAN 40 (DEV-OPS) to an access switch and assigns user ports to it. However, users in VLAN 40 cannot reach servers in VLAN 40 on the distribution switch. Verification reveals link carrier is up and zero errors appear under 'show interfaces ge-0/0/0'. What is the most likely root cause?
VLAN 40 is omitted from the 'vlan members' allowed list on trunk port ge-0/0/0, causing the switch to drop the frames silently at the Layer 2 parser level.
The physical trunk cable has failed because 802.1Q tagged frames require Cat6A copper cabling to carry tags above VID 32.
The switch ran out of Layer 2 MAC address table entries, forcing the PFE to discard incoming frames for newly created VLANs.
An access port must be configured with 'port-mode promiscuous' before its traffic can transit an inter-switch trunk link.