PracticeVideosBlogFlashcards

2.3 Compounding and Sterile Preparation

Key Takeaways

  • USP <795> governs non-sterile compounding; USP <797> governs sterile compounding.

  • Beyond-use dates (BUDs) differ from expiration dates and are assigned by the compounder.

  • Aseptic technique requires proper hand hygiene, garbing, and working in a laminar airflow hood.

  • ISO Class 5 environment is required for sterile compounding in the primary engineering control.

  • Hazardous drug compounding follows USP <800> with additional safety requirements.

Last updated: October 2026

Quick Answer: Non-sterile compounding follows USP <795> while sterile compounding follows USP <797>. Sterile products require ISO Class 5 environment, proper aseptic technique, and appropriate beyond-use dating. USP <800> covers hazardous drug handling.

USP Compounding Chapters

ChapterCoverageExamples
USP <795>Non-sterile compoundingCreams, ointments, capsules, oral liquids
USP <797>Sterile compoundingIV solutions, injections, ophthalmic preparations
USP <800>Hazardous drug handlingChemotherapy, hormone preparations

Non-Sterile Compounding (USP <795>)

What Counts as Non-Sterile Compounding

The 2022 revision of USP <795> eliminated the old simple, moderate, and complex compounding categories. Reconstituting a manufactured product according to its labeling is not compounding under the chapter; reconstitution that departs from the labeling is.

Equipment for Non-Sterile Compounding

  • Class A prescription balance (sensitivity 6 mg)
  • Graduated cylinders
  • Mortar and pestle
  • Ointment slab or parchment paper
  • Spatulas (metal and plastic)
  • Weighing boats or papers
  • Compounding log and formula records

Beyond-Use Dating for Non-Sterile Compounds

USP <795> (2022 revision), when there is no stability data:

TypeMaximum BUD (no stability data)
Nonpreserved aqueous dosage forms14 days (refrigerated)
Preserved aqueous dosage forms35 days
Nonaqueous oral liquids90 days
Other nonaqueous dosage forms (e.g., capsules, ointments)180 days

No BUD may exceed the shortest remaining expiration date of any commercially available starting component.

Important: Beyond-use date (BUD) is different from expiration date. BUD is assigned by the compounder; expiration date is from the manufacturer.

Sterile Compounding (USP <797>)

ISO Classifications

ISO ClassMax Particles (0.5 mcm) per m3Use
ISO Class 53,520Primary engineering control (hood)
ISO Class 7352,000Buffer area/clean room
ISO Class 83,520,000Ante area

Primary Engineering Controls (PECs)

TypeDescriptionUse
Horizontal Laminar Airflow Hood (LAFW)HEPA-filtered air flows toward workerNon-hazardous sterile compounding
Biological Safety Cabinet (BSC)Air exhausted through HEPA filterHazardous drugs
Compounding Aseptic Isolator (CAI)Enclosed isolator with HEPA-filtered ISO Class 5 airNon-hazardous sterile compounding (sterile hazardous drugs use a BSC or CACI)
Compounding Aseptic Containment Isolator (CACI)Enhanced containmentHazardous drugs

Aseptic Technique Requirements

Proper Hand Hygiene:

  1. Remove jewelry and artificial nails
  2. Wash hands and forearms with soap and water for at least 30 seconds
  3. Apply alcohol-based hand rub before gloving
  4. Don sterile gloves, then apply sterile 70% IPA to them before compounding and regularly throughout

Example Garbing Order (USP <797> does not set one order; your facility's SOP does, in an order that reduces contamination):

  1. Shoe covers
  2. Head cover (hair cover)
  3. Face mask
  4. Hand washing
  5. Non-shedding gown
  6. Sterile gloves (donned in a classified room or SCA; never donned or doffed inside the ISO Class 5 PEC with bare hands exposed)

Beyond-Use Dating for Sterile Compounds (CSPs)

Category 1 CSPs (12 Hours or Less at Room Temp):

StorageBUD
Room temperature12 hours
Refrigerated24 hours

Category 2 CSPs (prepared in an ISO Class 5 PEC inside an ISO-classified anteroom and buffer room): the maximum BUD depends on how the CSP was made.

Category 2 CSPRoom temperatureRefrigeratedFrozen (-25 to -10 C)
Aseptically processed, all sterile starting components, no sterility test4 days10 days45 days
Aseptically processed, any nonsterile starting component, no sterility test1 day4 days45 days
Aseptically processed, passed sterility testing30 days45 days60 days
Terminally sterilized, no sterility test14 days28 days45 days
Terminally sterilized, passed sterility testing45 days60 days90 days

A shorter BUD applies when stability data call for it. Category 3 CSPs, made under extra quality requirements, may have longer BUDs.

Clean Room Behavior Rules

  • No food, drink, or gum
  • No cosmetics or perfume
  • Speak minimally
  • Move slowly and deliberately
  • Never cough or sneeze toward work area
  • Keep hands away from face
  • Work at least 6 inches inside the front edge of the hood (ASHP guidance)
  • Never block HEPA filter airflow

IV Preparation Basics

Common IV Solutions

AbbreviationFull NameUses
NSNormal Saline (0.9% NaCl)Most common, isotonic
1/2 NSHalf Normal Saline (0.45% NaCl)Maintenance fluids
D5W5% Dextrose in WaterCaloric supplementation
D5NS5% Dextrose in Normal SalineFluid and calories
LRLactated Ringer'sResuscitation, surgery
D5LR5% Dextrose in LRCombination therapy

IV Flow Rate Calculations

Formula: gtt/min = (Volume x Drop Factor) / Time in minutes

IV Set TypeDrop Factor
Microdrip60 gtt/mL
Macrodrip (standard)10-20 gtt/mL

Worked Example: IV Flow Rate

Order: 1000 mL NS over 8 hours using 15 gtt/mL tubing

Step 1: Convert hours to minutes

  • 8 hours x 60 = 480 minutes

Step 2: Apply formula

  • gtt/min = (1000 mL x 15 gtt/mL) / 480 min
  • gtt/min = 15,000 / 480 = 31.25 gtt/min (round to 31)

Hazardous Drug Handling (USP <800>)

Requirements for Hazardous Drugs

RequirementDetails
Negative pressure roomPrevents contamination spread
Double glovingChemotherapy-rated gloves
Closed-system transfer devicesFor administration
Dedicated equipmentDo not share with non-hazardous
Spill kitReadily available
Medical surveillanceFor personnel exposure

Categories of Hazardous Drugs

  • Antineoplastic agents (chemotherapy)
  • Hormones and hormone antagonists
  • Some antivirals
  • Immunosuppressants
  • Bioengineered drugs

USP Chapters That Govern Compounding

Three USP chapters define the standards the ExCPT tests. Know which chapter applies to which activity.

USP ChapterScope
USP <795>Non-sterile compounding (creams, capsules, suspensions)
USP <797>Sterile compounding (IV admixtures, ophthalmics, injectables)
USP <800>Handling of hazardous drugs (chemotherapy, some hormones)

Exam Tip: If a question mentions a laminar flow hood, ISO-classified air, or aseptic technique, the governing chapter is USP <797>. If it mentions chemotherapy or a negative-pressure room, think USP <800>.


Primary Engineering Controls and Air Quality

Sterile compounding occurs inside primary engineering controls (PECs). Air cleanliness is rated by ISO class, where a lower number is cleaner.

ControlUse
Laminar airflow workbench (horizontal flow)Non-hazardous sterile products
Biological safety cabinet (vertical flow)Hazardous sterile products
Compounding aseptic isolator (CAI)Non-hazardous in a closed glovebox
Compounding aseptic containment isolator (CACI)Hazardous in a closed, negative-pressure glovebox

The direct compounding area inside a PEC must meet ISO Class 5. The buffer room is typically ISO Class 7 and the ante-room ISO Class 8.


Beyond-Use Dates (BUD)

A beyond-use date is the date after which a compounded preparation must not be used. It differs from the manufacturer expiration date on commercial stock. BUDs depend on the preparation type, storage temperature, and sterility.

PreparationTypical BUD Driver
Non-sterile (USP <795>)Water content, storage; assigned per published data
Sterile (USP <797>)CSP category (1, 2 or 3) and storage temperature
Repackaged unit doseEarlier of manufacturer expiration or guideline limit

Worked Example: A repackaged tablet has a manufacturer expiration of 18 months away, but the repackaging guideline caps the BUD at 6 months. The label must show the 6-month BUD because you always assign the earlier date.


Needles, Syringes, and Documentation

Sterile compounding also tests equipment knowledge. A higher needle gauge number means a thinner needle. Filter needles trap glass or rubber particles when drawing from an ampule. Every compounded or repackaged product requires documentation: ingredients, lot numbers, BUD, and the preparer's and checker's identities, retained per USP <795>/<797>.

Loading diagram...
Compounding Decision Flowchart
Test Your Knowledge

Which USP chapter governs the handling of hazardous drugs such as chemotherapy?

A

USP <795>

B

USP <797>

C

USP <800>

D

USP <71>

Test Your Knowledge

The direct compounding area inside a primary engineering control must meet which air quality classification?

A

ISO Class 5

B

ISO Class 7

C

ISO Class 8

D

No classification required

Test Your Knowledge

A repackaged tablet's manufacturer expiration is 12 months away, but the repackaging guideline limits the beyond-use date to 6 months. The label should show:

A

12 months

B

6 months

C

The midpoint, 9 months

D

No date is required

Sections you finish are checked off in the contents.